5 resultados para Special handling unit

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Many media reports suggest an increase in alcohol intoxication, particularly among young people. Indeed, several surveys on young people have confirmed this fact. These were based on self-declaration of alcohol consumption. However, there are few clinical data that show an increase in alcohol intoxication in hospitals. The aim of this study was to evaluate the number of alcohol intoxications in relation to the total number of patients and to look for a statistical trend.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Mortality and morbidity are particularly high in the building industry. The annual rate of non-fatal occupational accidents in Switzerland is 1,133 per 100,000 inhabitants. METHODS: Retrospective analysis of the electronic database of a university emergency centre. Between 2001 and 2011, 782 occupational accidents to construction workers were recorded and analysed using specific demographic and medical keywords. RESULTS: Most patients were aged 30-39 (30.4%). 66.4% of the injured workers were foreigners. This is almost twice as high as the overall proportion of foreigners in Switzerland or in the Swiss labour market. 16% of the Swiss construction workers and 8% of the foreign construction workers suffered a severe injury with ISS >15. There was a trend for workers aged 60 and above to suffer an accident with a high ISS (p = 0.089). CONCLUSIONS: As in other European countries, most patients were in their thirties. Older construction workers suffered fewer injuries, although these tended to be more severe. The injuries were evenly distributed through the working days of the week. A special effort should be made that current health and safety measures are understood and applied by foreign and older construction workers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Hyponatremia is frequently observed in intensive care unit (ICU) patients, but there is still lack information on the physiological mechanisms of development. MATERIALS AND METHODS In this retrospective analysis we performed tonicity balances in 54 patients with ICU acquired hyponatremia. We calculated fluid and solute in and outputs during 24 hours in 106 patient days with decreasing serum-sodium levels. RESULTS We could observe a positive fluid balance as a single reason for hyponatremia in 25% of patients and a negative solute balance in 57%. In 18% both factors contributed to the decrease in serum-sodium. Hyponatremic patients had renal water retention, measured by electrolyte free water clearance calculation in 79% and positive input of free water in 67% as reasons for decline of serum-sodium. The theoretical change of serum sodium during 24 hours according to the calculations of measured balances correlated well with the real change of serum sodium (r = 0.78, P < .01). CONCLUSIONS Balance studies showed that renal water retention together with renal sodium loss and high electrolyte free water input are the major contributors to the development of hyponatremia. Control of renal water and sodium handling by urine analysis may contribute to a better fluid management in the ICU population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients suffering from cystic fibrosis (CF) show thick secretions, mucus plugging and bronchiectasis in bronchial and alveolar ducts. This results in substantial structural changes of the airway morphology and heterogeneous ventilation. Disease progression and treatment effects are monitored by so-called gas washout tests, where the change in concentration of an inert gas is measured over a single or multiple breaths. The result of the tests based on the profile of the measured concentration is a marker for the severity of the ventilation inhomogeneity strongly affected by the airway morphology. However, it is hard to localize underlying obstructions to specific parts of the airways, especially if occurring in the lung periphery. In order to support the analysis of lung function tests (e.g. multi-breath washout), we developed a numerical model of the entire airway tree, coupling a lumped parameter model for the lung ventilation with a 4th-order accurate finite difference model of a 1D advection-diffusion equation for the transport of an inert gas. The boundary conditions for the flow problem comprise the pressure and flow profile at the mouth, which is typically known from clinical washout tests. The natural asymmetry of the lung morphology is approximated by a generic, fractal, asymmetric branching scheme which we applied for the conducting airways. A conducting airway ends when its dimension falls below a predefined limit. A model acinus is then connected to each terminal airway. The morphology of an acinus unit comprises a network of expandable cells. A regional, linear constitutive law describes the pressure-volume relation between the pleural gap and the acinus. The cyclic expansion (breathing) of each acinus unit depends on the resistance of the feeding airway and on the flow resistance and stiffness of the cells themselves. Special care was taken in the development of a conservative numerical scheme for the gas transport across bifurcations, handling spatially and temporally varying advective and diffusive fluxes over a wide range of scales. Implicit time integration was applied to account for the numerical stiffness resulting from the discretized transport equation. Local or regional modification of the airway dimension, resistance or tissue stiffness are introduced to mimic pathological airway restrictions typical for CF. This leads to a more heterogeneous ventilation of the model lung. As a result the concentration in some distal parts of the lung model remains increased for a longer duration. The inert gas concentration at the mouth towards the end of the expirations is composed of gas from regions with very different washout efficiency. This results in a steeper slope of the corresponding part of the washout profile.