68 resultados para Space research activities
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
The present document has been elaborated in the context of the ERA-ARD project “The Agricultural Research for Development (ARD) dimension of the European Research Area (ERA) “. It is based on work done within Task 3.2 to identify a set of common or compatible methodologies for ARD planning, monitoring and evaluation and impact assessment. This set should serve as a guide for the management of joint ARD activities that are presently developed within the framework of the ERA-ARD project.
Resumo:
Networks are known to improve performance and create synergies. A research network can provide a significant advantage for all parties involved in research in surgery by systematically tracking the outcome of a huge number of patients over a long period of time. The aim of the present study was to investigate the experiences of surgeons with respect to research activities, to evaluate the opinions of surgeons with regard to the development of a national network for research in the field of surgery in Switzerland and to obtain data on how such a network should be designed.
Resumo:
The Imager for Low Energetic Neutral Atoms test facility at the University of Bern was developed to investigate, characterize, and quantify physical processes on surfaces that are used to ionize neutral atoms before their analysis in neutral particle-sensing instruments designed for space research. The facility has contributed valuable knowledge of the interaction of ions with surfaces (e.g., fraction of ions scattered from surfaces and angular scattering distribution) and employs a novel measurement principle for the determination of secondary electron emission yields as a function of energy, angle of incidence, particle species, and sample surface for low particle energies. Only because of this test facility it was possible to successfully apply surface-science processes for the new detection technique for low-energetic neutral particles with energies below about 1 keV used in space applications. All successfully flown spectrometers for the detection of low-energetic neutrals based on the particle–surface interaction process use surfaces evaluated, tested, and calibrated in this facility. Many instruments placed on different spacecraft (e.g., Imager for Magnetopause-to-Aurora Global Exploration, Chandrayaan-1, Interstellar Boundary Explorer, etc.) have successfully used this technique.
Resumo:
Recent findings related to childhood leukaemia incidence near nuclear installations have raised questions which can be answered neither by current knowledge on radiation risk nor by other established risk factors. In 2012, a workshop was organised on this topic with two objectives: (a) review of results and discussion of methodological limitations of studies near nuclear installations; (b) identification of directions for future research into the causes and pathogenesis of childhood leukaemia. The workshop gathered 42 participants from different disciplines, extending widely outside of the radiation protection field. Regarding the proximity of nuclear installations, the need for continuous surveillance of childhood leukaemia incidence was highlighted, including a better characterisation of the local population. The creation of collaborative working groups was recommended for consistency in methodologies and the possibility of combining data for future analyses. Regarding the causes of childhood leukaemia, major fields of research were discussed (environmental risk factors, genetics, infections, immunity, stem cells, experimental research). The need for multidisciplinary collaboration in developing research activities was underlined, including the prevalence of potential predisposition markers and investigating further the infectious aetiology hypothesis. Animal studies and genetic/epigenetic approaches appear of great interest. Routes for future research were pointed out.
Resumo:
We measured the elemental composition on a sample of Allende meteorite with a miniature laser ablation mass spectrometer. This Laser Mass Spectrometer (LMS) has been designed and built at the University of Bern in the Department of Space Research and Planetary Sciences with the objective of using such an instrument on a space mission. Utilising the meteorite Allende as the test sample in this study, it is demonstrated that the instrument allows the in situ determination of the elemental composition and thus mineralogy and petrology of untreated rocky samples, particularly on planetary surfaces. In total, 138 measurements of elemental compositions have been carried out on an Allende sample. The mass spectrometric data are evaluated and correlated with an optical image. It is demonstrated that by illustrating the measured elements in the form of mineralogical maps, LMS can serve as an element imaging instrument with a very high spatial resolution of µm scale. The detailed analysis also includes a mineralogical evaluation and an investigation of the volatile element content of Allende. All findings are in good agreement with published data and underline the high sensitivity, accuracy and capability of LMS as a mass analyser for space exploration.
Resumo:
Two polycrystalline diamond surfaces, manufactured by chemical vapour deposition (CVD) technique, are investigated regarding their applicability as charge state conversion surfaces (CS) for use in a low energy neutral atom imaging instrument in space research. The capability of the surfaces for converting neutral atoms into negative ions via surface ionisation processes was measured for hydrogen and oxygen with particle energies in the range from 100 eV to 1 keV and for angles of incidence between 6 deg and 15 deg. We observed surface charging during the surface ionisation processes for one of the CVD samples due to low electrical conductivity of the material. Measurements on the other CVD diamond sample resulted in ionisation efficiencies of ~2 % for H and up to 12 % for O. Analysis of the angular scattering revealed very narrow and almost circular scattering distributions. Comparison of the results with the data of the CS of the IBEX-Lo sensor shows that CVD diamond has great potential as CS material for future space missions.