51 resultados para Sound walk
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In the field of computer assisted orthopedic surgery (CAOS) the anterior pelvic plane (APP) is a common concept to determine the pelvic orientation by digitizing distinct pelvic landmarks. As percutaneous palpation is - especially for obese patients - known to be error-prone, B-mode ultrasound (US) imaging could provide an alternative means. Several concepts of using ultrasound imaging to determine the APP landmarks have been introduced. In this paper we present a novel technique, which uses local patch statistical shape models (SSMs) and a hierarchical speed of sound compensation strategy for an accurate determination of the APP. These patches are independently matched and instantiated with respect to associated point clouds derived from the acquired ultrasound images. Potential inaccuracies due to the assumption of a constant speed of sound are compensated by an extended reconstruction scheme. We validated our method with in-vitro studies using a plastic bone covered with a soft-tissue simulation phantom and with a preliminary cadaver trial.
Resumo:
To assess the relationship between nationality, gender and age and use of health services among patients visiting an urban university hospital emergency department (ED).
Resumo:
The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.
Resumo:
The present study evaluates the long-term effects of a preschool training in phonological awareness and letter- sound correspondence.
Resumo:
Background Patients often establish initial contact with healthcare institutions by telephone. During this process they are frequently medically triaged. Purpose To investigate the safety of computer-assisted telephone triage for walk-in patients with non-life-threatening medical conditions at an emergency unit of a Swiss university hospital. Methods This prospective surveillance study compared the urgency assessments of three different types of personnel (call centre nurses, hospital physicians, primary care physicians) who were involved in the patients' care process. Based on the urgency recommendations of the hospital and primary care physicians, cases which could potentially have resulted in an avoidable hazardous situation (AHS) were identified. Subsequently, the records of patients with a potential AHS were assessed for risk to health or life by an expert panel. Results 208 patients were enrolled in the study, of whom 153 were assessed by all three types of personnel. Congruence between the three assessments was low. The weighted κ values were 0.115 (95% CI 0.038 to 0.192) (hospital physicians vs call centre), 0.159 (95% CI 0.073 to 0.242) (primary care physicians vs call centre) and 0.377 (95% CI 0.279 to 0.480) (hospital vs primary care physicians). Seven of 153 cases (4.57%; 95% CI 1.85% to 9.20%) were classified as a potentially AHS. A risk to health or life was adjudged in one case (0.65%; 95% CI 0.02% to 3.58%). Conclusion Medical telephone counselling is a demanding task requiring competent specialists with dedicated training in communication supported by suitable computer technology. Provided these conditions are in place, computer-assisted telephone triage can be considered to be a safe method of assessing the potential clinical risks of patients' medical conditions.
Resumo:
To compare the patient benefit of the Bone-Anchored Hearing Aid (Baha) Divino and the Baha BP100 sound processors.
Resumo:
Patients with schizophrenia are impaired in many aspects of auditory processing, but indirect evidence suggests that intensity perception is intact. However, because the extraction of meaning from dynamic intensity relies on structures that appear to be altered in schizophrenia, we hypothesized that the perception of auditory looming is impaired as well. Twenty inpatients with schizophrenia and 20 control participants, matched for age, gender, and education, gave intensity ratings of rising (looming) and falling intensity sounds with different mean intensities. Intensity change was overestimated in looming as compared with receding sounds in both groups. However, healthy individuals showed a stronger effect at higher mean intensity, in keeping with previous findings, while patients with schizophrenia lacked this modulation. We discuss how this might support the notion of a more general deficit in extracting emotional meaning from different sensory cues, including intensity and pitch.
Resumo:
A device based on infrared laser fluorescence (IRLF) has become available as an adjunct for the diagnosis of dental caries.