81 resultados para Small Animal
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Transgenic mouse models of human cancers represent one of the most promising approaches to elucidate clinically relevant mechanisms of action and provide insights into the treatment efficacy of new antitumor drugs. The use of Trp53 transgenic mice (Trp53 knockout [Trp53(-/-)] mice) for these kinds of studies is, so far, restricted by limitations in detecting developing tumors and the lack of noninvasive tools for monitoring tumor growth, progression, and treatment response.
Resumo:
OBJECTIVES: To (1) review the development and medical applications of hydroxyethyl starch (HES) solutions with particular emphasis on its physiochemical properties; (2) critically appraise the available evidence in human and veterinary medicine, and (3) evaluate the potential risks and benefits associated with their use in critically ill small animals. DATA SOURCES: Human and veterinary original research articles, scientific reviews, and textbook sources from 1950 to the present. HUMAN DATA SYNTHESIS: HES solutions have been used extensively in people for over 30 years and ever since its introduction there has been a great deal of debate over its safety and efficacy. Recently, results of seminal trials and meta-analyses showing increased risks related to kidney dysfunction and mortality in septic and critically ill patients, have led to the restriction of HES use in these patient populations by European regulatory authorities. Although the initial ban on the use of HES in Europe has been eased, proof regarding the benefits and safety profile of HES in trauma and surgical patient populations has been requested by these same European regulatory authorities. VETERINARY DATA SYNTHESIS: The veterinary literature is limited mostly to experimental studies and clinical investigations with small populations of patients with short-term end points and there is insufficient evidence to generate recommendations. CONCLUSIONS: Currently, there are no consensus recommendations regarding the use of HES in veterinary medicine. Veterinarians and institutions affected by the HES restrictions have had to critically reassess the risks and benefits related to HES usage based on the available information and sometimes adapt their procedures and policies based on their reassessment. Meanwhile, large, prospective, randomized veterinary studies evaluating HES use are needed to achieve relevant levels of evidence to enable formulation of specific veterinary guidelines.
Resumo:
Preclinical in vivo experimental studies are performed for evaluating proof-of-principle concepts, safety and possible unwanted reactions of candidate bone biomaterials before proceeding to clinical testing. Specifically, models involving small animals have been developed for screening bone biomaterials for their potential to enhance bone formation. No single model can completely recreate the anatomic, physiologic, biomechanic and functional environment of the human mouth and jaws. Relevant aspects regarding physiology, anatomy, dimensions and handling are discussed in this paper to elucidate the advantages and disadvantages of small-animal models. Model selection should be based not on the 'expertise' or capacities of the team, but rather on a scientifically solid rationale, and the animal model selected should reflect the question for which an answer is sought. The rationale for using heterotopic or orthotopic testing sites, and intraosseous, periosseous or extraskeletal defect models, is discussed. The paper also discusses the relevance of critical size defect modeling, with focus on calvarial defects in rodents. In addition, the rabbit sinus model and the capsule model in the rat mandible are presented and discussed in detail. All animal experiments should be designed with care and include sample-size and study-power calculations, thus allowing generation of meaningful data. Moreover, animal experiments are subject to ethical approval by the relevant authority. All procedures and the postoperative handling and care, including postoperative analgesics, should follow best practice.
Resumo:
OBJECTIVES This case series describes 5 dogs with small intestinal intussusception and acute kidney injury due to infection with Leptospira interrogans serovar Australis. CASE SERIES SUMMARY Small intestinal intussusception was observed in 4 dogs diagnosed with acute kidney injury due to leptospirosis presented between 1997 and 2005. Intussusception was diagnosed at initial presentation or later during hospitalization. An additional dog fulfilling our inclusion criteria was presented to a small animal specialty clinic nearby and was included. Upon admission, all dogs were severely azotemic and thrombocytopenic. All 5 dogs showed the strongest microscopic agglutination test serology reaction to L. interrogans serovar Australis. Two dogs survived with no apparent residual renal damage, 1 survived with subsequent mild chronic kidney disease, and 2 dogs were euthanized at the owners' request due to a guarded prognosis. NEW OR UNIQUE INFORMATION PROVIDED Intussusception can occur or may be seen in dogs with leptospirosis due to L. interrogans serovar Australis and patients should be monitored closely for this potential complication. As all 5 dogs described in this case series showed the highest titer for L. interrogans serovar Australis, these precautions may be especially applied in geographic areas where this particular serovar is seen.
Resumo:
Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.
Resumo:
Ablative procedures that are used for the improvement of a degenerative process that leads to a loss of skin elasticity and integrity, injure or destroy the epidermis and its basement membrane and lead to fibrosis of the papillary dermis. It was recently shown in clinical and laboratory trials that percutaneous collagen induction (PCI) by multiple needle application is a method for safely treating wrinkles and scars and smoothening the skin without the risk of dyspigmentation. In our study, we describe the effect of PCI on epidermal thickness and the induction of genes relevant for regenerative processes in the skin in a small animal model.
Resumo:
Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2 ), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400-500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes ("venous" PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60-120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.
Resumo:
A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil showed an SNR increase at the periphery and in the center of the phantom of 3- and 1.3-fold, respectively. Comparison with a shorter but SNR-optimized birdcage coil (aspect ratio 1:1 and only half mouse coverage) showed an SNR gain of twofold at the edge of the phantom and similar SNR in the center. G-factor measurements indicate that the coil is well suited to acquire highly accelerated images.
Resumo:
Funduscopy is one of the most commonly used diagnostic tools in the ophthalmic practice, allowing for a ready assessment of pathological changes in the retinal vasculature and the outer retina. This non-invasive technique has so far been rarely used in animal model for ophthalmic diseases, albeit its potential as a screening assay in genetic screens. The zebrafish (Danio rerio) is well suited for such genetic screens for ocular alterations. Therefore we developed funduscopy in adult zebrafish and employed it as a screening tool to find alterations in the anterior segment and the fundus of the eye of genetically modified adult animals.A stereomicroscope with coaxial reflected light illumination was used to obtain fundus color images of the zebrafish. In order to find lens and retinal alterations, a pilot screen of 299 families of the F3 generation of ENU-treated adult zebrafish was carried out.Images of the fundus of the eye and the anterior segment can be rapidly obtained and be used to identify alterations in genetically modified animals. A number of putative mutants with cataracts, defects in the cornea, eye pigmentation, ocular vessels and retina were identified. This easily implemented method can also be used to obtain fundus images from rodent retinas.In summary, we present funduscopy as a valuable tool to analyse ocular abnormalities in adult zebrafish and other small animal models. A proof of principle screen identified a number of putative mutants, making funduscopy based screens in zebrafish feasible.
Resumo:
The low-energy β− emitter 161Tb is very similar to 177Lu with respect to half-life, beta energy and chemical properties. However, 161Tb also emits a significant amount of conversion and Auger electrons. Greater therapeutic effect can therefore be expected in comparison to 177Lu. It also emits low-energy photons that are useful for gamma camera imaging. The 160Gd(n,γ)161Gd→161Tb production route was used to produce 161Tb by neutron irradiation of massive 160Gd targets (up to 40 mg) in nuclear reactors. A semiautomated procedure based on cation exchange chromatography was developed and applied to isolate no carrier added (n.c.a.) 161Tb from the bulk of the 160Gd target and from its stable decay product 161Dy. 161Tb was used for radiolabeling DOTA-Tyr3-octreotate; the radiolabeling profile was compared to the commercially available n.c.a. 177Lu. A 161Tb Derenzo phantom was imaged using a small-animal single-photon emission computed tomography camera. Up to 15 GBq of 161Tb was produced by long-term irradiation of Gd targets. Using a cation exchange resin, we obtained 80%–90% of the available 161Tb with high specific activity, radionuclide and chemical purity and in quantities sufficient for therapeutic applications. The 161Tb obtained was of the quality required to prepare 161Tb–DOTA-Tyr3-octreotate. We were able to produce 161Tb in n.c.a. form by irradiating highly enriched 160Gd targets; it can be obtained in the quantity and quality required for the preparation of 161Tb-labeled therapeutic agents.
Resumo:
OBJECTIVE: To assess patterns of seroreactivity to Leptospira serovars in veterinary professional staff and dog owners exposed to dogs with acute leptospirosis and to contrast these patterns in people with those observed in dogs. DESIGN: Cross-sectional study. SAMPLE POPULATION: Human subjects consisted of 91 people (50 veterinarians, 19 technical staff, 9 administrative personnel, and 13 dog owners) exposed to dogs with leptospirosis. Canine subjects consisted of 52 dogs with naturally occurring leptospirosis admitted to the University of Bern Vetsuisse Faculty Small Animal Clinic in 2007 and 2008. PROCEDURES: People were tested for seroreactivity to regionally prevalent Leptospira serovars by use of a complement fixation test. A questionnaire designed to identify risk factors associated with seropositivity was used to collect demographic information from each study participant. Dogs were tested for seroreactivity to Leptospira serovars by use of a microscopic agglutination test. RESULTS: On the basis of microscopic agglutination test results, infected dogs were seropositive for antibodies against Leptospira serovars as follows (in descending order): Bratislava (43/52 [83%]), Australis (43/52 [83%]), Grippotyphosa (18/52 [35%]), Pomona (12/52 [23%]), Autumnalis (6/52 [12%]), Icterohemorrhagiae (4/52 [8%]), Tarassovi (2/52 [4%]), and Canicola (1/52 [2%]). All 91 people were seronegative for antibodies against Leptospira serovars. Therefore, statistical evaluation of risk factors and comparison of patterns of seroreactivity to Leptospira serovars between human and canine subjects were limited to theoretical risks. CONCLUSIONS AND CLINICAL RELEVANCE: Seroreactivity to Leptospira serovars among veterinary staff adhering to standard hygiene protocols and pet owners exposed to dogs with acute leptospirosis was uncommon.
Resumo:
OBJECTIVES: To describe the occurrence of systemic hypertension in dogs with acute kidney injury and the efficacy of amlodipine besylate for its treatment. METHODS: This retrospective study included 52 dogs with acute kidney injury (2007 to 2008) grouped based on the use of amlodipine in their treatment. Systemic blood pressure was measured with an oscillometric device at admission, before, during, and after amlodipine therapy. RESULTS: Occurrence of systolic systemic hypertension (>/=160 mmHg) and severe systolic systemic hypertension (>/=180 mmHg) was 37% and 15% at admission and increased with hospitalisation to 81% and 62%, respectively. Twenty-two dogs were treated with amlodipine, at a median daily dosage of 0.38 mg/kg (interquartile range 0.28 to 0.49) divided in one to two applications per day. Amlodipine therapy was associated with a decrease in systolic systemic blood pressure of 24 mmHg (12 to 34) and a correction of severe systemic hypertension in 10 of 11 dogs within 24 hours. Overall, 73% of the dogs survived with a significantly lower proportion of survivors in treated compared to non-treated dogs (59% versus 83%, respectively, P=0.05). CLINICAL SIGNIFICANCE: Results of this study reveal that systemic hypertension is common in canine acute kidney injury and that treatment with amlodipine is beneficial in reducing systemic hypertension. The potential effect of amlodipine on global outcome requires prospective assessment.
Resumo:
Low-field (LF) (0.2-0.4T) magnetic resonance (MR) imaging predominates in veterinary practice. Advantages of LF MR include reduced costs, better patient access, and greater safety. High quality examinations can be achieved using appropriate protocols and investing more scanning time than with high-field (HF) systems. The main disadvantage of LF MR is the reduced signal to noise ratio compared with HF systems. LF MR protocols for small animal brain and spine imaging are described.