57 resultados para Skull Radiography

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To test the null hypothesis that there is no difference between premolar position visualized on panoramic radiographs (PRs) and lateral headfilms (LHs). MATERIALS AND METHODS: The prevalence of differences in the direction of crown angulation between PR and LH was assessed. Furthermore, brass wire markers with different sagittal and transverse angulations were placed in a dry skull. With the markers in place, LHs and PRs were taken. RESULTS: A difference in the direction of crown angulation of unerupted second premolars between PR and LH occurred in 19.5% of patients. The reason for the angulation differences is a buccolingual orientation of the tooth, which appears as a mesiodistal angulation on the PR. CONCLUSION: The null hypothesis was rejected since in one-fifth of the patients premolar projection differs between the panoramic radiograph and the lateral headfilm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of our study was to compare the performance of low-dose linear slit digital radiography (DR) with computed radiography (CR) for the detection of trauma sequelae in the chest including rib fractures, pneumothorax, and lung contusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the diagnostic accuracy and time effectiveness of the Statscan low-dose full-body digital x-ray machine in the evaluation of ventriculoperitoneal (VP) shunt dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the detectability and dimensions of periapical lesions, the relationship of the mandibular canal to the roots of the respective teeth, and the dimension of the buccal bone by using limited cone-beam computed tomography (CBCT) in comparison to conventional periapical (PA) radiographs for evaluation of mandibular molars before apical surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the occurrence, sites, and types of associated injuries in paediatric patients with fractures of the anterior skull base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lodox Statscan provides high-speed, high-quality, low radiation, full body imaging in a single scan, combined with three-dimensional reconstructive and zooming functionality. Several trauma centres have incorporated it into their advanced trauma life support protocol. This review gives a brief overview of the system.