11 resultados para Single-plane angiography

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPC(PH)). Institutions were retrospectively requested to irradiate their institutional phantom (INST(PH)) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPC(PH) and INST(PH) were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPC(PH) and INST(PH) (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INST(PH) measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPC(PH) and INST(PH) comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel variable decomposition approach for pose recovery of the distal locking holes using single calibrated fluoroscopic image. The problem is formulated as a model-based optimal fitting process, where the control variables are decomposed into two sets: (a) the angle between the nail axis and its projection on the imaging plane, and (b) the translation and rotation of the geometrical model of the distal locking hole around the nail axis. By using an iterative algorithm to find the optimal values of the latter set of variables for any given value of the former variable, we reduce the multiple-dimensional model-based optimal fitting problem to a one-dimensional search along a finite interval. We report the results of our in vitro experiments, which demonstrate that the accuracy of our approach is adequate for successful distal locking of intramedullary nails.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS: All patients gave written informed consent after the study details, including radiation exposure, were explained. The study protocol was approved by the local institutional review board. In patients referred for elective conventional coronary angiography, an additional 64-section CT angiography study and a myocardial perfusion imaging study (1-day adenosine stress-rest protocol) with technetium 99m-tetrofosmin SPECT were performed before conventional angiography. Coronary artery diameter narrowing of 50% or greater at CT angiography was defined as stenosis and was compared with the myocardial perfusion imaging findings. Quantitative coronary angiography served as a reference standard for CT angiography. RESULTS: A total of 1093 coronary segments in 310 coronary arteries in 78 patients (mean age, 65 years +/- 9 [standard deviation]; 35 women) were analyzed. CT angiography revealed stenoses in 137 segments (13%) corresponding to 91 arteries (29%) in 46 patients (59%). SPECT revealed 14 reversible, 13 fixed, and six partially reversible defects in 31 patients (40%). Sensitivity, specificity, and negative and positive predictive values, respectively, of CT angiography in the detection of reversible myocardial perfusion imaging defects were 95%, 53%, 94%, and 58% on a per-patient basis and 95%, 75%, 96%, and 72% on a per-artery basis. Agreement between CT and conventional angiography was very good (96% and kappa = 0.92 for patient-based analysis, 93% and kappa = 0.84 for vessel-based analysis). CONCLUSION: Sixty-four-section CT angiography can help rule out hemodynamically relevant CAD in patients with intermediate to high pretest likelihood, although an abnormal CT angiography study is a poor predictor of ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exudative age-related macular degeneration (AMD) is a sight-threatening event in many elderly people. Some patients have a much better outcome in visual acuity (VA) than others after treatment with photodynamic therapy (PDT) with verteporfin. The combination of fluorescein angiography (FA) and indocyanine green (ICG) angiography using the Heidelberg Retina Angiograph II (HRA 2) should make a delineation of distinct pattern(s) possible in order to better select and assess therapy. METHODS: This is a retrospective, case-control, single-centre study. We identified a total of 168 eyes of 168 patients from July 2003 to June 2006, including 30 eyes of 30 patients with better visual outcome, defined in this study as VA < or = 0.48 logMAR (> or =20/60 Snellen chart) at the end of the study. Best-corrected VA, maximal central retinal thickness as measured by optical coherence tomography, and results of the FA/ICG angiography using the HRA 2 were analyzed. In this article, we discuss patients with polypoidal choroidal vasculopathy (PCV) and their characteristics. RESULTS: The average follow-up time was 15.3 months (range 4-28 months). Seventeen (57%) of the 30 patients with better visual outcome had PCV. All patients in the group with better visual outcome needed fewer PDT treatments compared with our control group of patients with an exudative AMD. INTERPRETATION: Simultaneous FA/ICG angiography using the HRA 2 allowed delineation of a subgroup of patients with PCV who showed a better visual outcome compared with those with other types of exudative AMD, after treatment with PDT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous analyses of aortic displacement and distension using computed tomography angiography (CTA) were performed on double-oblique multi-planar reformations and did not consider through-plane motion. The aim of this study was to overcome this limitation by using a novel computational approach for the assessment of thoracic aortic displacement and distension in their true four-dimensional extent. Vessel segmentation with landmark tracking was executed on CTA of 24 patients without evidence of aortic disease. Distension magnitudes and maximum displacement vectors (MDV) including their direction were analyzed at 5 aortic locations: left coronary artery (COR), mid-ascending aorta (ASC), brachiocephalic trunk (BCT), left subclavian artery (LSA), descending aorta (DES). Distension was highest for COR (2.3 ± 1.2 mm) and BCT (1.7 ± 1.1 mm) compared with ASC, LSA, and DES (p < 0.005). MDV decreased from COR to LSA (p < 0.005) and was highest for COR (6.2 ± 2.0 mm) and ASC (3.8 ± 1.9 mm). Displacement was directed towards left and anterior at COR and ASC. Craniocaudal displacement at COR and ASC was 1.3 ± 0.8 and 0.3 ± 0.3 mm. At BCT, LSA, and DES no predominant displacement direction was observable. Vessel displacement and wall distension are highest in the ascending aorta, and ascending aortic displacement is primarily directed towards left and anterior. Craniocaudal displacement remains low even close to the left cardiac ventricle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Defocus blur is an indicator for the depth structure of a scene. However, given a single input image from a conventional camera one cannot distinguish between blurred objects lying in front or behind the focal plane, as they may be subject to exactly the same amount of blur. In this paper we address this limitation by exploiting coded apertures. Previous work in this area focuses on setups where the scene is placed either entirely in front or entirely behind the focal plane. We demonstrate that asymmetric apertures result in unique blurs for all distances from the camera. To exploit asymmetric apertures we propose an algorithm that can unambiguously estimate scene depth and texture from a single input image. One of the main advantages of our method is that, within the same depth range, we can work with less blurred data than in other methods. The technique is tested on both synthetic and real images.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.