27 resultados para Silicone elastomer
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To assess the long-term results of double bicanalicular silicone tubes in canalicular (presaccal) stenosis of the nasolacrimal duct system, a retrospective follow-up was performed on patients operated between 1992 and 2002. Forty-five patients were included in the study, 44 of whom had eyes with canalicular stenosis (primary dacryocystorhinostomy), 4 with congenital agenesis of the lacrimal duct system, and 3 cases after primary external dacryocystorhinostomy. Double bicanalicular silicone tubes were inserted, fixed in the vestibulum nasi, and left in place as long-term space holders. Of the 51 endonasal primary dacryocystorhinostomies with canalicular stenosis, 32 (63%) became symptom-free after one procedure. Nineteen (37%) patients had a relapse. Double silicone bicanalicular tube insertion as long-term spacers in canalicular stenoses has a number of advantages, but canalicular stenoses still remain a challenging area.
Resumo:
BACKGROUND: Heavier than water tamponades offer the possibility to support the inferior part of the fundus after retinal detachment. The aim of this study was to evaluate the anatomic and functional outcome of complicated retinal detachment treated with vitreous surgery and heavy silicone oil (HSO) tamponade. Surgery was performed in eyes with rhegmatogenous retinal detachment (RD) predominantly in the lower hemisphere or with penetrating injury (either as primary intervention or after development of proliferative vitreoretinopathy [PVR]). MATERIALS AND METHODS: Sixty-one eyes of 61 patients with RD - mostly complicated by PVR - and a minimum follow-up of 12 months were included in this study. Vitreoretinal surgery with HSO (Oxane HD) tamponade was performed in all patients. In 52 patients, heavy silicone oil was used in the management of complicated RD. 9 patients had surgery for complicated RD after penetrating eye injury.The mean follow-up period was 30.3 +/- 10.2 months. RESULTS: The overall final anatomic success rate was 79 %. In 39 % of the cases the retina remained attached during the entire follow-up period. CONCLUSIONS: The anatomic success rate after surgery with HSO (Oxane HD) was relatively low; however, only complex cases bearing a higher risk of retinal re-detachment received HSO in this study. Oxane HD does not appear to have major advantages compared to conventional silicone oil or other new-generation heavy silicone oils in these cases.
Resumo:
BACKGROUND The fingertip is the most commonly injured part of the hand and is an important aesthetic part of the hand. METHODS In this retrospective study we analyzed data from 700 patients operated on between 1997 and 2008 for complications after nail splinting with native nail or silicone nail. Inclusion criteria were patients living in Bern/Berner Land, complete documentation, same surgical team, standard antibiotics, acute trauma, no nail bed transplantation, and no systemic diseases. Groups were analyzed for differences in age, gender, cause and extension of trauma, bony injury and extent, infection, infectious agent, and nail deformities. Statistical analysis was done using the χ (2) test, Fisher's exact test, and Pearson correlation coefficients. RESULTS A total of 401 patients, with a median age of 39.5 years, were included. There were more men with injured nails. Two hundred forty native nails and 161 silicone splints were used. There were 344 compression injuries, 44 amputations, and 13 avulsion injuries. Forty-three patients had an infection, with gram-positive bacteria (Staphylococcus aureus) causing most infections. A total of 157 nail dystrophies were observed, split nails most often. The native nail splint group showed significantly (p < 0.015) fewer nail deformities than the silicone nail splint group; otherwise, there were no statistical differences. However, there were twice as many infections in the silicone nail group. CONCLUSION It seems to be advantageous to use the native nail for splinting after trauma, when possible. In case of a destroyed and unusable nail plate, a nail substitute has to be used.
Resumo:
Mechanical stress controls a broad range of cellular functions. The cytoskeleton is physically connected to the extracellular matrix via integrin receptors, and to the nuclear lamina by the LINC complex that spans both nuclear membranes. We asked here how disruption of this direct link from the cytoskeleton to nuclear chromatin affects mechanotransduction. Fibroblasts grown on flexible silicone membranes reacted to cyclic stretch by nuclear rotation. This rotation was abolished by inhibition of actomyosin contraction as well as by overexpression of dominant-negative versions of nesprin or sun proteins that form the LINC complex. In an in vitro model of muscle differentiation, cyclic strain inhibits differentiation and induces proliferation of C2C12 myoblasts. Interference with the LINC complex in these cells abrogated their stretch-induced proliferation, while stretch increased p38 MAPK and NFkappaB phosphorylation and the transcript levels of myogenic transcription factors MyoD and myogenin. We found that the physical link from the cytoskeleton to the nuclear lamina is crucial for correct mechanotransduction, and that disruption of the LINC complex perturbs the mechanical control of cell differentiation.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
Combined extended nerve and soft tissue defects of the upper extremity require nerve reconstruction and adequate soft tissue coverage. This study focuses on the reliability of the free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap within this indication. An anatomical study was performed on 26 cadaveric lower extremities that had been Thiel fixated and color silicone injected. Dissection of the fasciocutaneous posterior calf flap involved the medial sural nerve and superficial sural artery (SSA) with its septocutaneous perforators, extended laterally to include the lateral cutaneous branch of the sural nerve and continued to the popliteal origin of the vascular pedicle and the nerves. The vessel and nerves diameter were measured with an eyepiece reticle at 4.5× magnification. Length and diameter of the nerves and vessels were carefully assessed and reported in the dissection book. A total of 26 flaps were dissected. The SSA originated from the medial sural artery (13 cases), the popliteal artery (12 cases), or the lateral sural artery (one case). The average size of the SSA was 1.4 ± 0.4 mm. The mean pedicle length before the artery joined the sural nerve was 4.5 ± 1.9 cm. A comitant vein was present in 21 cases with an average diameter of 2.0 ± 0.8 mm, in 5 cases a separate vein needed to be dissected with an average diameter of 3.5 ± 0.4 mm. The mean medial vascularized sural nerve length was 21.2 ± 8.9 cm. Because of inclusion of the vascularized part of the lateral branch of the sural nerve (mean length of 16.7 ± 4.8 cm), a total of 35.0 ± 9.6 cm mean length of vascularized nerve could be gained from each extremity. The free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap pedicled on the SSA offers a reliable solution for complex tissue and nerve defect. Clin. Anat. 2012. © 2012 Wiley Periodicals, Inc.
Enamel loss and adhesive remnants following bracket removal and various clean-up procedures in vitro
Resumo:
This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.
Resumo:
The performance of three elastomeric materials for the open monophase implant impressions technique was tested under the following clinical conditions: polyether (IM) and vinylsiloxanether without (ID) and with additional simultaneous splinting of the implant impression copings with a higher shore hardness A-silicone (IDF).
Resumo:
Binding of hydrophobic chemicals to colloids such as proteins or lipids is difficult to measure using classical microdialysis methods due to low aqueous concentrations, adsorption to dialysis membranes and test vessels, and slow kinetics of equilibration. Here, we employed a three-phase partitioning system where silicone (polydimethylsiloxane, PDMS) serves as a third phase to determine partitioning between water and colloids and acts at the same time as a dosing device for hydrophobic chemicals. The applicability of this method was demonstrated with bovine serum albumin (BSA). Measured binding constants (K(BSAw)) for chlorpyrifos, methoxychlor, nonylphenol, and pyrene were in good agreement with an established quantitative structure-activity relationship (QSAR). A fifth compound, fluoxypyr-methyl-heptyl ester, was excluded from the analysis because of apparent abiotic degradation. The PDMS depletion method was then used to determine partition coefficients for test chemicals in rainbow trout (Oncorhynchus mykiss) liver S9 fractions (K(S9w)) and blood plasma (K(bloodw)). Measured K(S9w) and K(bloodw) values were consistent with predictions obtained using a mass-balance model that employs the octanol-water partition coefficient (K(ow)) as a surrogate for lipid partitioning and K(BSAw) to represent protein binding. For each compound, K(bloodw) was substantially greater than K(S9w), primarily because blood contains more lipid than liver S9 fractions (1.84% of wet weight vs 0.051%). Measured liver S9 and blood plasma binding parameters were subsequently implemented in an in vitro to in vivo extrapolation model to link the in vitro liver S9 metabolic degradation assay to in vivo metabolism in fish. Apparent volumes of distribution (V(d)) calculated from the experimental data were similar to literature estimates. However, the calculated binding ratios (f(u)) used to relate in vitro metabolic clearance to clearance by the intact liver were 10 to 100 times lower than values used in previous modeling efforts. Bioconcentration factors (BCF) predicted using the experimental binding data were substantially higher than the predicted values obtained in earlier studies and correlated poorly with measured BCF values in fish. One possible explanation for this finding is that chemicals bound to proteins can desorb rapidly and thus contribute to metabolic turnover of the chemicals. This hypothesis remains to be investigated in future studies, ideally with chemicals of higher hydrophobicity.
Resumo:
BACKGROUND: Recently, several cases of symptomatic and/or electrically detectable intracardiac inside-out abrasions in silicon-coated Riata® and Riata® ST leads have been described. However, the prevalence in asymptomatic patients with unremarkable implantable cardioverter defibrillator (ICD) interrogation is unknown. The aim of this study was to determine the prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads. METHODS: All 52 patients with an active silicone-coated Riata® and Riata® ST lead followed up in our outpatient clinic were scheduled for a premature ICD interrogation and a biplane chest radiograph. When an intracardiac inside-out abrasion was suspected, this finding was confirmed by fluoroscopy. RESULTS: Mean time since implantation was 71±18months. An intracardiac inside-out abrasion was confirmed by fluoroscopy in 6 patients (11.5%). Mean time from lead implantation to detection of intracardiac inside-out abrasion was 79±14months. In all patients with an intracardiac inside-out abrasion, ICD interrogation showed normal and stable electrical parameters. Retrospectively, in 4 of these 6 patients, a coronary angiography performed 25±18months before diagnosis of intracardiac inside-out abrasion already showed the defect. Despite undetected intracardiac inside-out abrasion, 2 of these 4 patients experienced adequate antitachycardia pacing and ICD-shocks. ICD leads were replaced in all 6 patients. CONCLUSIONS: The prevalence of asymptomatic intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads is higher than 10% when assessed by fluoroscopy, and most intracardiac inside-out abrasions are not detectable by ICD interrogation.
Resumo:
Profound evidence substantiates significantly reduced risk of catheter-related infections with prophylactic use of rifampin- and clindamycin-impregnated silicone catheters (Bactiseal(®), Codman Johnson & Johnson, Raynham, MA, USA) for external ventricular drainage (EVD). However, whether Bactiseal(®)-EVD (B-EVD) influences the treatment of EVD-related ventriculitis remains controversial.
Resumo:
Cerebrospinal fluid (CSF) shunts carry a high risk of complications. Infections represent a major cause of shunt failure. Diagnosis and therapy of such infections are complicated by the formation of bacterial biofilms attached to shunt surfaces. This study correlated the pathophysiology and clinical course of biofilm infections with microscopical findings on the respective shunts. Surface irregularities, an important risk-factor for shunt colonisation with bacteria, were found to increase over time because of silicone degradation. Scanning electron-microscopy (SEM) documented residual biological material (dead biofilm), which can further promote extant bacterial adhesion, on newly manufactured shunts. Clinical course and SEM both documented bacterial dissemination against CSF flow and the monodirectional valve. In all cases, biofilms grew on both the inner and outer surfaces of the shunts. Microscopy and conventional culture detected all bacterial shunt infections. Analyses of 16S rDNA sequences using conserved primers identified bacteria in only one of three cases, probably because of previous formalin fixation of the samples.