31 resultados para Sight-singing.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute non-specific abdominal pain (NSAP) is prevalent in 6-25% of the general population and is a common cause of admission to the emergency department (ED). Despite involvement of substantial financial and human resources, there are few data on long-term outcome after initial diagnosis. The aim of this study was to evaluate long-term outcome of patients initially admitted with NSAP to an ED.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Photodynamic therapy (PDT) is the standard treatment procedure for many forms of exudative and/or neovascular AMD. Despite therapy, visual acuity often drops to low vision levels. The cost efficiency of treating the eye in which vision is worse is therefore the subject of some controversy. PATIENTS AND METHODS: A retrospective case-control study was conducted in all patients who were treated with PDT at the Universitätsspital Zürich between September 1999 and November 2004. Each patient's first (with worse vision) and second (with better vision) eyes were compared for situation on presentation and course during treatment. RESULTS: In 117/228 cases (51.3%) visual acuity of the treated eye was better than (or identical to) that of the fellow eye at presentation. Visual acuity before therapy was an average of 0.58+/-0.27 logMAR [Snellen: 0.26 (0.14-0.49)] in the eyes with better visual acuity and 0.69+/-0.4 logMAR [Snellen 0.20 (0.08-0.51)] in the fellow eyes (p=0.015). After therapy there was no significant difference between the patient groups in visual acuity or in the magnitude of any change in visual acuity, or in lesion size or change in lesion size. CONCLUSION: The outcome of PDT of a second eye (with better visual acuity) is not significantly better than the result obtained in the first eye (the one with worse visual acuity initially).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When sight-reading a piece of music the eyes constantly scan the score slightly ahead of music execution. This separation between reading and acting is commonly termed eye-hand span and can be expressed in two ways: as anticipation in notes or in time. Previous research, predominantly in piano players, found skill-dependent differences of eye-hand span. To date no study has explored visual anticipation in violinists. The present study investigated how structural properties of a piece of music affect the eye-hand span in a group of violinists. To this end eye movements and bow reversals were recorded synchronously while musicians sight-read a piece of music. The results suggest that structural differences of the score are reflected in the eye-hand span in a way similar to skill level. Specifically, the piece with higher complexity was associated with lower anticipation in notes, longer fixation duration and a tendency for more regressive fixations. Anticipation in time, however, remained the same (approximately 1 s) independently of the score played but was correlated with playing tempo. We conclude that the eye-hand span is not only influenced by the experience of the musician, but also by the structure of the score to be played.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Moebius sequence is a congenital disorder that not only affects the oculomotor system but also the eyes themselves. Ocular involvement might be sight-threatening and needs regular follow-up by an ophthalmologist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the human body, over 1000 different G protein-coupled receptors (GPCRs) mediate a broad spectrum of extracellular signals at the plasma membrane, transmitting vital physiological features such as pain, sight, smell, inflammation, heart rate and contractility of muscle cells. Signaling through these receptors is primarily controlled and regulated by a group of kinases, the GPCR kinases (GRKs), of which only seven are known and thus, interference with these common downstream GPCR regulators suggests a powerful therapeutic strategy. Molecular modulation of the kinases that are ubiquitously expressed in the heart has proven GRK2, and also GRK5, to be promising targets for prevention and reversal of one of the most severe pathologies in man, chronic heart failure (HF). In this article we will focus on the structural aspects of these GRKs important for their physiological and pathological regulation as well as well known and novel therapeutic approaches that target these GRKs in order to overcome the development of cardiac injury and progression of HF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Severe postoperative loss of vision has been occasionally reported as a rare complication of retrobulbar anesthesia, and several possible causes have been proposed in the literature. In this work, our own and other investigators' experiences with these complications are surveyed with a view to identifying its pathophysiology. PATIENTS: This observational case series refers to six patients who presented during a 3-month period with occlusion of either the central artery itself (n = 3) or a branch thereof (n = 3) 2-14 days after uneventful vitreoretinal surgery following retrobulbar anesthesia with a commercial preparation of mepivacaine (1% Scandicain®, Astra Chemicals, Sweden) containing methyl- and propyl parahydroxybenzoate as preservatives. RESULTS: Three of the patients carried risk factors, which were medically controlled. In three individuals, vasoocclusion was observed after a second vitreoretinal intervention, which was performed 3-12 months after uneventful primary surgery. Good visual recovery was observed in only one instance. CONCLUSIONS: In patients who were anesthetized with preservative-free mepivacaine, no vasoocclusion occurred. In individuals who were anesthetized with mepivacaine containing the preservatives methyl- and propyl parahydroxybenzoate, a tenfold increase in the incidence of eyes requiring re-operation was documented, with a 2- to 14-day lapse in the onset of vasoocclusion. These findings reveal a possible implication of preservatives contained in the local anesthetic solution for the vasoocclusive events. Due to this potential hazard, the use of preservative-free preparations of local anesthesia in ocular surgery is emphasized in order to prevent this sight-threatening complication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Presenting visual feedback for image-guided surgery on a monitor requires the surgeon to perform time-consuming comparisons and diversion of sight and attention away from the patient. Deficiencies in previously developed augmented reality systems for image-guided surgery have, however, prevented the general acceptance of any one technique as a viable alternative to monitor displays. This work presents an evaluation of the feasibility and versatility of a novel augmented reality approach for the visualisation of surgical planning and navigation data. The approach, which utilises a portable image overlay device, was evaluated during integration into existing surgical navigation systems and during application within simulated navigated surgery scenarios.