13 resultados para Sieved orthogonal polynomials on the unit circle

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

By a theorem of A'Campo, the eigenvalues of certain Coxeter transformations are positive real or lie on the unit circle. By optimally bounding the signature of tree-like positive Hopf plumbings from below by the genus, we prove that at least two thirds of them lie on the unit circle. In contrast, we show that for divide links, the signature cannot be linearly bounded from below by the genus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rotator cuff lesions are common and the incidence increases with age. After tendon rupture of the rotator cuff, the muscle-tendon unit retracts, which is accompanied by muscle fatty infiltration, atrophy, and interstitial fibrosis of the musculature, thus, fundamentally changing the muscle architecture. These changes are important prognostic factors for the operative rotator cuff reconstruction outcome. Selection of the correct time point for reconstruction as well as the optimal mechanical fixation technique are decisive for successful attachment at the tendon-to-bone insertion site. Thus, knowledge of the pathophysiological processes plays an important role. The goal of this article is to establish a relationship between currently existing evidence with respect to the preoperatively existing changes of the muscle-tendon unit and the choice of the time for the operation and the operative technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Materials and methods Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance–Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal–Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Results Maximum irradiances were 1,545 mW/cm2 (SM), 2,179 mW/cm2 (HPM), and 4,156 mW/cm2 (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Conclusions Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. Clinical relevance When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We engineer a brane picture for the reduction of Seiberg dualities from 4D to 3D, valid also in the presence of orientifold planes. We obtain effective 3D dualities on the circle by T-duality, geometrizing the non-perturbative superpotential which is an affine Toda potential. When reducing to pure 3D, we define a double-scaling limit which creates a sector of interacting singlets, giving a unified mechanism for the brane reduction of dualities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Muscular weakness and muscle wasting may often be observed in critically ill patients on intensive care units (ICUs) and may present as failure to wean from mechanical ventilation. Importantly, mounting data demonstrate that mechanical ventilation itself may induce progressive dysfunction of the main respiratory muscle, i.e. the diaphragm. The respective condition was termed 'ventilator-induced diaphragmatic dysfunction' (VIDD) and should be distinguished from peripheral muscular weakness as observed in 'ICU-acquired weakness (ICU-AW)'. Interestingly, VIDD and ICU-AW may often be observed in critically ill patients with, e.g. severe sepsis or septic shock, and recent data demonstrate that the pathophysiology of these conditions may overlap. VIDD may mainly be characterized on a histopathological level as disuse muscular atrophy, and data demonstrate increased proteolysis and decreased protein synthesis as important underlying pathomechanisms. However, atrophy alone does not explain the observed loss of muscular force. When, e.g. isolated muscle strips are examined and force is normalized for cross-sectional fibre area, the loss is disproportionally larger than would be expected by atrophy alone. Nevertheless, although the exact molecular pathways for the induction of proteolytic systems remain incompletely understood, data now suggest that VIDD may also be triggered by mechanisms including decreased diaphragmatic blood flow or increased oxidative stress. Here we provide a concise review on the available literature on respiratory muscle weakness and VIDD in the critically ill. Potential underlying pathomechanisms will be discussed before the background of current diagnostic options. Furthermore, we will elucidate and speculate on potential novel future therapeutic avenues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose We hypothesized that reduced arousability (Richmond Agitation Sedation Scale, RASS, scores −2 to −3) for any reason during delirium assessment increases the apparent prevalence of delirium in intensive care patients. To test this hypothesis, we assessed delirium using the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and Intensive Care Delirium Screening Checklist (ICDSC) in intensive care patients during sedation stops, and related the findings to the level of sedation, as assessed with RASS score. Methods We assessed delirium in 80 patients with ICU stay longer than 48 h using CAM-ICU and ICDSC during daily sedation stops. Sedation was assessed using RASS. The effect of including patients with a RASS of −2 and −3 during sedation stop (“light to moderate sedation”, eye contact less than 10 s or not at all, respectively) on prevalence of delirium was analyzed. Results A total of 467 patient days were assessed. The proportion of CAM-ICU-positive evaluations decreased from 53 to 31 % (p < 0.001) if assessments from patients at RASS −2/−3 (22 % of all assessments) were excluded. Similarly, the number of positive ICDSC results decreased from 51 to 29 % (p < 0.001). Conclusions Sedation per se can result in positive items of both CAM-ICU and ICDSC, and therefore in a diagnosis of delirium. Consequently, apparent prevalence of delirium is dependent on how a depressed level of consciousness after sedation stop is interpreted (delirium vs persisting sedation). We suggest that any reports on delirium using these assessment tools should be stratified for a sedation score during the assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stable carbon isotope analysis of methane (delta C-13 of CH4) on atmospheric samples is one key method to constrain the current and past atmospheric CH4 budget. A frequently applied measurement technique is gas chromatography (GC) isotope ratio mass spectrometry (IRMS) coupled to a combustion-preconcentration unit. This report shows that the atmospheric trace gas krypton (Kr) can severely interfere during the mass spectrometric measurement, leading to significant biases in delta C-13 of CH4, if krypton is not sufficiently separated during the analysis. According to our experiments, the krypton interference is likely composed of two individual effects, with the lateral tailing of the doubly charged Kr-86 peak affecting the neighbouring m/z 44 and partially the m/z 45 Faraday cups. Additionally, a broad signal affecting m/z 45 and especially m/z 46 is assumed to result from scattered ions of singly charged krypton. The introduced bias in the measured isotope ratios is dependent on the chromatographic separation, the krypton-to-CH4 mixing ratio in the sample, the focusing of the mass spectrometer as well as the detector configuration and can amount to up to several per mil in delta C-13. Apart from technical solutions to avoid this interference, we present correction routines to a posteriori remove the bias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In extracts of senescent leaves of the tobacco plant Nicotiana rustica, two colorless compounds with UV/VIS characteristics of nonfluorescent chlorophyll catabolites (NCCs) were detected and tentatively identified as Nr-NCCs. These two polar NCCs were found in similar amounts in the fresh extracts, and their constitutions could be determined by spectroscopic analysis. The data showed both of the two Nr-NCCs to have the same tetrapyrrolic core structure, as reported previously for all other NCCs from senescent higher plants. In the less polar catabolite, named Nr-NCC-2, this core structure was conjugated with a glucopyranose unit, as similarly discovered earlier in Bn-NCC-2, an NCC from oilseed rape (Brassica napus). The more polar NCC from tobacco leaves, Nr-NCC-1, carried an additional malonyl substituent at the 6′-OH group of the glucopyranosyl moiety. Partial (enzyme-catalyzed) hydrolysis of Nr-NCC-1 gave Nr-NCC-2, while enzyme-catalyzed malonylation of Nr-NCC-2 gave Nr-NCC-1, establishing the identity of their basic tetrapyrrole structure. In earlier work (on the polar NCCs from oilseed rape), only separate glucopyranosyl and malonyl functionalities were detected. Nr-NCC-1, thus, represents a further variant of the structures of NCCs from senescent higher plants and exhibits an unprecedented peripheral refunctionalization in chlorophyll catabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Inferolateral early repolarization (ER) is highly prevalent and is associated with idiopathic ventricular fibrillation (VF). OBJECTIVE The purpose of this study was to evaluate the potential role of T-wave parameters to differentiate between malignant and benign ER. METHODS We compared the ECGs of patients with ER and VF (n = 92) with control subjects with asymptomatic ER (n = 247). We assessed J-wave amplitude, QTc interval, T-wave/R-wave (T/R) ratio in leads II and V5, and presence of low-amplitude T waves (T-wave amplitude <0.1 mV and <10% of R-wave amplitude in lead I, II, or V4-V6). RESULTS Compared to controls, the VF group had longer QTc intervals (388 ms vs 377 ms, P = .001), higher J-wave amplitudes (0.23 mV vs 0.17 mV, P <.001), higher prevalence of low-amplitude T waves (29% vs 3%, P <.001), and lower T/R ratio (0.18 vs 0.30, P <.001). Logistic regression analysis demonstrated that QTc interval (odds ratio [OR] per 10 ms: 1.15, 95% confidence interval [CI} 1.02-1.30), maximal J-wave amplitude (OR per 0.1 mV: 1.68, 95% CI 1.23-2.31), lower T/R ratio (OR per 0.1 unit: 0.62, 95% CI 0.47-0.81), presence of low-amplitude T waves (OR 3.53, 95% CI 1.26-9.88). and presence of J waves in the inferior leads (OR 2.58, 95% CI 1.18-5.65) were associated with malignant ER. CONCLUSION Patients with malignant ER have a higher prevalence of low-amplitude T waves, lower T/R ratio (lead II or V5), and longer QTc interval. The combination of these parameters with J-wave amplitude and distribution of J waves may allow for improved identification of malignant ER.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Charged massive matter fields of spin-0 and spin- 1/2 are quantized in the presence of an external uniform magnetic field in a spatial region bounded by two parallel plates. The most general set of boundary conditions at the plates, that is required by mathematical consistency and the self-adjointness of the Hamiltonian operator, is employed. The vacuum fluctuations of the matter field in the case of the magnetic field orthogonal to the plates are analyzed, and it is shown that the pressure from the vacuum onto the plates is positive and independent of the boundary condition, as well as of the distance between the plates. Possibilities of the detection of this new-type Casimir effect are discussed. Read More: http://www.worldscientific.com/doi/10.1142/S0217732315500996