45 resultados para Shishkin mesh
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Mesh fixation during laparoscopic ventral hernia repair can be performed using transfascial sutures or metal tacks. The aim of the present study is to compare mesh shrinkage and pain between two different techniques of mesh fixation in a prospective randomized trial.
Resumo:
Background Men who have sex with men (MSM) remain the group most at risk of acquiring HIV infection in Britain. HIV prevalence appears to vary widely between MSM from different ethnic minority groups in this country for reasons that are not fully understood. The aim of the MESH project was to examine in detail the sexual health of ethnic minority MSM living in Britain. Methods/Design The main objectives of the MESH project were to explore among ethnic minority MSM living in Britain: (i) sexual risk behaviour and HIV prevalence; (ii) their experience of stigma and discrimination; (iii) disclosure of sexuality; (iv) use of, and satisfaction with sexual health services; (v) the extent to which sexual health services (for treatment and prevention) are aware of the needs of ethnic minority MSM. The research was conducted between 2006 and 2008 in four national samples: (i) ethnic minority MSM living in Britain; (ii) a comparison group of white British MSM living in Britain; (iii) NHS sexual health clinic staff in 15 British towns and cities with significant ethnic minority communities and; (iv) sexual health promotion/HIV prevention service providers. We also recruited men from two "key migrant" groups living in Britain: MSM born in Central or Eastern Europe and MSM born in Central or South America. Internet-based quantitative and qualitative research methods were used. Ethnic minority MSM were recruited through advertisements on websites, in community venues, via informal networks and in sexual health clinics. White and "key migrant" MSM were recruited mostly through Gaydar, one of the most popular dating sites used by gay men in Britain. MSM who agreed to take part completed a questionnaire online. Ethnic minority MSM who completed the online questionnaire were asked if they would be willing to take part in an online qualitative interview using email. Service providers were identified through the British Association of Sexual Health and HIV (BASHH) and the Terrence Higgins Trust (THT) CHAPS partnerships. Staff who agreed to take part were asked to complete a questionnaire online. The online survey was completed by 1241 ethnic minority MSM, 416 men born in South and Central America or Central and Eastern Europe, and 13,717 white British MSM; 67 ethnic minority MSM took part in the online qualitative interview. In addition 364 people working in sexual health clinics and 124 health promotion workers from around Britain completed an online questionnaire. Discussion The findings from this study will improve our understanding of the sexual health and needs of ethnic minority MSM in Britain.
Resumo:
The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CT (μCT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 μm) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young’s moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 μm resolutions. Improvements were not significant for the 64 μm, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.
Resumo:
Statistical models have been recently introduced in computational orthopaedics to investigate the bone mechanical properties across several populations. A fundamental aspect for the construction of statistical models concerns the establishment of accurate anatomical correspondences among the objects of the training dataset. Various methods have been proposed to solve this problem such as mesh morphing or image registration algorithms. The objective of this study is to compare a mesh-based and an image-based statistical appearance model approaches for the creation of nite element(FE) meshes. A computer tomography (CT) dataset of 157 human left femurs was used for the comparison. For each approach, 30 finite element meshes were generated with the models. The quality of the obtained FE meshes was evaluated in terms of volume, size and shape of the elements. Results showed that the quality of the meshes obtained with the image-based approach was higher than the quality of the mesh-based approach. Future studies are required to evaluate the impact of this finding on the final mechanical simulations.
Resumo:
The purpose of this study was to share our clinical experience in the use and accuracy of a newly designed, low-profile titanium mesh (Modus OPS 1.5; Medartis, Basel, Switzerland) for primary internal orbital reconstruction.
Resumo:
Genital prolapse is frequent and can be found in about 50% of parous women. Its etiology is complex and multifactorial. Predisposing factors include: genetics (connective tissue disorders, family history); general state (age, parity, weight, smoking, obstructive pulmonary disease); trauma (carrying heavy loads, intense physical exercise); or iatrogenic (post hysterectomy). Treatment can be conservative or surgical and depends mainly on the severity of symptoms. Developments in surgical techniques and synthetic material in the last 20 years enabled us to use minimally invasive procedures with improved post operative course and decreased recurrence rates.
Resumo:
Following Lichtenstein hernia repair, up to 25% of patients experience prolonged postoperative and chronic pain as well as discomfort in the groin. One of the underlying causes of these complaints are the compression or irritation of nerves by the sutures used to fixate the mesh. We compared the level and rate of chronic pain in patients operated with the classical Lichtenstein technique fixated by sutures to patients with sutureless mesh fixation technique.