14 resultados para Sens of touch
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Non-invasive documentation methods such as surface scanning and radiological imaging are gaining in importance in the forensic field. These three-dimensional technologies provide digital 3D data, which are processed and handled in the computer. However, the sense of touch gets lost using the virtual approach. The haptic device enables the use of the sense of touch to handle and feel digital 3D data. The multifunctional application of a haptic device for forensic approaches is evaluated and illustrated in three different cases: the representation of bone fractures of the lower extremities, by traffic accidents, in a non-invasive manner; the comparison of bone injuries with the presumed injury-inflicting instrument; and in a gunshot case, the identification of the gun by the muzzle imprint, and the reconstruction of the holding position of the gun. The 3D models of the bones are generated from the Computed Tomography (CT) images. The 3D models of the exterior injuries, the injury-inflicting tools and the bone injuries, where a higher resolution is necessary, are created by the optical surface scan. The haptic device is used in combination with the software FreeForm Modelling Plus for touching the surface of the 3D models to feel the minute injuries and the surface of tools, to reposition displaced bone parts and to compare an injury-causing instrument with an injury. The repositioning of 3D models in a reconstruction is easier, faster and more precisely executed by means of using the sense of touch and with the user-friendly movement in the 3D space. For representation purposes, the fracture lines of bones are coloured. This work demonstrates that the haptic device is a suitable and efficient application in forensic science. The haptic device offers a new way in the handling of digital data in the virtual 3D space.
Resumo:
With the increasing use of medical imaging in forensics, as well as the technological advances in rapid prototyping, we suggest combining these techniques to generate displays of forensic findings. We used computed tomography (CT), CT angiography, magnetic resonance imaging (MRI) and surface scanning with photogrammetry in conjunction with segmentation techniques to generate 3D polygon meshes. Based on these data sets, a 3D printer created colored models of the anatomical structures. Using this technique, we could create models of bone fractures, vessels, cardiac infarctions, ruptured organs as well as bitemark wounds. The final models are anatomically accurate, fully colored representations of bones, vessels and soft tissue, and they demonstrate radiologically visible pathologies. The models are more easily understood by laypersons than volume rendering or 2D reconstructions. Therefore, they are suitable for presentations in courtrooms and for educational purposes.
Resumo:
Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.
Resumo:
The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.
Resumo:
BACKGROUND: Neonates in a neonatal intensive care unit are exposed to a high number of painful procedures. Since repeated and sustained pain can have consequences for the neurological and behaviour-oriented development of the newborn, the greatest attention needs to be paid to systematic pain management in neonatology. Non-pharmacological treatment methods are being increasingly discussed with regard to pain prevention and relief either alone or in combination with pharmacological treatment. AIMS: To identify effective non-pharmacological interventions with regard to procedural pain in neonates. METHODS: A literature search was conducted via the MedLine, CINAHL, Cochrane Library databases and complemented by a handsearch. The literature search covered the period from 1984 to 2004. Data were extracted according to pre-defined criteria by two independent reviewers and methodological quality was assessed. RESULTS: 13 randomised controlled studies and two meta-analyses were taken into consideration with regard to the question of current nursing practice of non-pharmacological pain management methods. The selected interventions were "non-nutritive sucking", "music", "swaddling", "positioning", "olfactory and multisensorial stimulation", "kangaroo care" and "maternal touch". There is evidence that the methods of "non-nutritive sucking", "swaddling" and "facilitated tucking" do have a pain-alleviating effect on neonates. CONCLUSIONS: Some of the non-pharmacological interventions have an evident favourable effect on pulse rate, respiration and oxygen saturation, on the reduction of motor activity, and on the excitation states after invasive measures. However, unambiguous evidence of this still remains to be presented. Further research should emphasise the use of validated pain assessment instruments for the evaluation of the pain-alleviating effect of non-pharmacological interventions.
Resumo:
OBJECTIVE: Conventional harvesting of saphenous vein used for coronary artery bypass surgery induces a vasospasm that is overcome by high-pressure distension. Saphenous vein harvested with its cushion of perivascular tissue by a "no touch" technique does not undergo vasospasm and distension is not required, leading to an improved graft patency. The aim of this study is to investigate the effect of surgical damage and high-pressure distension on endothelial integrity and endothelial nitric oxide synthase expression and activity in saphenous vein harvested with and without perivascular tissue. METHODS: Saphenous veins from patients (n = 26) undergoing coronary artery bypass surgery were prepared with and without perivascular tissue. We analyzed the effect of 300 mm Hg distension on morphology and endothelial nitric oxide synthase/nitric oxide synthase activity using a combination of immunohistochemistry, Western blot analysis, reverse transcriptase polymerase chain reaction, and enzyme assay in distended (with and without perivascular tissue) compared with nondistended (with and without perivascular tissue) segments. RESULTS: Distension induced substantial damage to the luminal endothelium (assessed by CD31 staining) and vessel wall. Endothelial nitric oxide synthase expression and activity were significantly reduced by high-pressure distension and removal of, or damage to, perivascular tissue. The effect of distension was significantly less for those with perivascular tissue than for those without perivascular tissue in most cases. CONCLUSION: The success of the saphenous vein used as a bypass graft is affected by surgical trauma and distension. Veins removed with minimal damage exhibit increased patency rates. We show that retention of perivascular tissue on saphenous vein prepared for coronary artery bypass surgery by the "no touch" technique protects against distension-induced damage, preserves vessel morphology, and maintains endothelial nitric oxide synthase/nitric oxide synthase activity.
Resumo:
The results of Eurosceptic parties in the recent European parliament election provide further evidence that the “permissive consensus” on European integration blurred. This paper focuses on the structure of the debate on EU integration issues. Which EU integration issues and positions do parties put forward? Can the debate on EU integration issues be subsumed in one or several dimensions? Do they reflect national political conflicts such as the left-right and the ‘new politics’/cultural divide? Or do they form one unique or several EU-specific dimensions, e.g. national sovereignty versus integration? In order to address these questions, this paper departs from the assumption that debate on European integration is multidimensional in its nature and therefore entails a multitude of issue areas. In other words, it does not look at how socio-economic and cultural issues are related to European integration but focuses on its components, i.e. particular EU-specific policies such as EU-wide employment, environment, immigration and monetary policy. The paper departs from the cleavage theory on political di-visions and different approaches transferring them to EU politics. Two points should be noted; first, this paper does not compare the debate on European integration issues between the national level and the EU level, but whether domestic divisions are reflected at the EU level. Second, it is not concerned with the general ideo-logical profile of political parties on EU integration issues, but on EU issues that parties communicated through press releases. By doing this, the paper is concerned with the salient EU issues that parties touch upon.
Resumo:
Purpose: Traditionally, the proximal isovelocity surface area (PISA) is based on the assumption of a single hemisphere (hemispheric PISA), but this technique has not been validated for the quantification of mitral regurgitation (MR) with multiple jets. Methods: The left heart simulator was actuated by a pulsatile pump at various stroke amplitudes. The regurgitant volume (Rvol) passing through the mitral valve phantoms with single and double regurgitant orifices of varying size and interspace was quantified by a flowmeter as reference technique. Color Doppler 3-D full-volumes were obtained, and Rvol were derived from 2-D PISA surfaces on the basis of hemispheric and hemicylindric assumption with one base (partial hemicylindric PISA) or 2 bases (total hemicylindric PISA). Results: 72 regurgitant volumes (Rvol range: 8 to 76 ml/beat) were obtained. Hemispheric PISA Rvol correlated well with reference Rvol by one orifice (R²=0.97; bias -2.7±3.2ml), but less by ≥ one orifice (R²=0.89). When a fusion of two PISAs occured, addition of two hemispheric PISA overestimated Rvol (bias 9.1±12.2ml, fig.1), and single hemispheric PISA underestimated Rvol (bias -12.4±4.9ml). If an integrated approach was used (hemispheric in single orifice, total hemicylindric in two non-fused PISAs and partial hemicylindric in two fused PISAs), the correlation was R²=0.95, bias -1.6±5.6ml (fig.2). In the ROC analysis, the cutoff to detect ≥ moderate-to-severe Rvol (≥45ml) was 42ml (AUC 0.99, sens. 100%, spec. 93%). Conclusions: In MR with two regurgitant jets, the 2-D hemicylindric assumption of the PISA offers a better quantification of Rvol than the hemispheric assumption. Quantification of MR using 2-D PISA requires an integrated approach that considers number of regurgitant orifices and fusion of the PISAs.