7 resultados para Self-expadable stents

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new era of stroke treatment may have begun with mechanical thrombectomy (MT) by fully deployed closed-cell self-expanding stents (stent-triever). Multiple case series and the first randomised controlled trials (RCTs) have now been published. More studies are under way involving large numbers of patients, which in turn has resulted in less strict "pragmatic" study protocols. Problems with current trials include a lack of standardisation in the conduct of the recanalisation procedure, the definition of primary endpoints such as the grade of arterial recanalisation and tissue reperfusion, and the post-surgical care provided. In Part 1 of this two part series, we outline the current situation and the major research questions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess the effect of stent type on hypotension and bradycardia after carotid artery stent placement. MATERIALS AND METHODS: A retrospective analysis on a prospectively maintained database was conducted in 256 patients (126 men; mean age, 71.8 years +/- 8.6; 194 de novo lesions) undergoing carotid artery stent placement between January 1996 and January 2007 by using self-expanding stents. Braided Elgiloy stents (Wallstents) were used in 44 of the 256 patients (17.2%) and slotted-tube nitinol stents were deployed in 212 (82.8%). Bivariate and multivariable logistic regression models were used to determine the influence of stent design on procedural and 24-hour hypotension and bradycardia. RESULTS: Procedural hemodynamic depression (HD) was encountered in 73 of the 256 patients (28.5%) due to hypotension in 24 (9.4%), bradycardia in 12 (4.7%), or both in 37 (14.5%) patients. Rates of procedural hypotension were 11.3% with nitinol stents and 0% with braided Elgiloy stents (P = .0188). Persistent postprocedural HD occurred in 91 of the 256 patients (35.5%) due to hypotension in 40 patients (15.6%), bradycardia in 23 (9.0%), or both in 28 (10.9%). Within a multivariable analysis adjusted for clinically relevant factors affecting rates of HD, the use of braided Elgiloy stents was associated with a decreased rate of procedural hypotension (odds ratio: 0.165; 95% confidence interval: 0.038, 0.721; P = .017). Procedural hypotension and bradycardia were not correlated to incidence of major adverse events but were associated with an increased duration of hospital stay (P = .0059 and P = .0335, respectively). CONCLUSIONS: Nitinol stents are associated with a higher risk of hypotension as compared to braided Elgiloy stents during carotid artery stent placement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was performed to evaluate feasibility, efficacy, and safety of intracranial artery recanalization for acute ischemic stroke using a self-expandable stent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Different stents in infrainguinal arteries have recently been associated with stent fractures and unfavorable clinical outcome, although data is limited regarding fractures of the Xpert selfexpanding nitinol stent. Thus, purpose of the present investigation was to evaluate its incidence and clinical implications in lower limb arteries. PATIENTS AND METHODS: Fifty-three consecutive patients (53 limbs) with peripheral arterial disease underwent secondary Xpert stent implantation due to suboptimal primary balloon angioplasty (PTA). Median age was 76 years. Stent fractures were evaluated by plain X-ray at median follow-up of 16 months. Stent patency was assessed by duplex ultrasound and sustained clinical improvement was defined as improvement of the ABI of > or = 0.10 together with improvement of at least one Rutherford class above the baseline finding throughout follow-up. RESULTS: Median length of femoropopliteal and infrapopliteal lesion was 3.0 and 2.3 cm, respectively. Sixtyfive stents were implanted in 43 limbs with femoropopliteal and 10 stents in 10 limbs with infrapopliteal lesion, respectively. Stent fractures occurred in 3 of 43 limbs (7.0%) of patients with femoropopliteal lesion with stent-based fracture rate of 4.6%. All fractured stents showed multiple struts fractures and occurred in the distal and middle superficial femoral artery. No stent fracture was observed in infrapopliteal lesions. The fractured stents were not associated with any clinical deterioration. Sustained clinical improvement was 71.0% and 54.6% for femoropopliteal and infrapopliteal lesions, respectively. Stent patency assessed by duplex was 65.2 and 63.9% for femoropopliteal and infrapopliteal lesions, respectively. CONCLUSIONS: Fractures of the Xpert stent were seldom and not associated with unfavorable clinical outcome at midterm follow-up.