5 resultados para Section 35

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS: All patients gave written informed consent after the study details, including radiation exposure, were explained. The study protocol was approved by the local institutional review board. In patients referred for elective conventional coronary angiography, an additional 64-section CT angiography study and a myocardial perfusion imaging study (1-day adenosine stress-rest protocol) with technetium 99m-tetrofosmin SPECT were performed before conventional angiography. Coronary artery diameter narrowing of 50% or greater at CT angiography was defined as stenosis and was compared with the myocardial perfusion imaging findings. Quantitative coronary angiography served as a reference standard for CT angiography. RESULTS: A total of 1093 coronary segments in 310 coronary arteries in 78 patients (mean age, 65 years +/- 9 [standard deviation]; 35 women) were analyzed. CT angiography revealed stenoses in 137 segments (13%) corresponding to 91 arteries (29%) in 46 patients (59%). SPECT revealed 14 reversible, 13 fixed, and six partially reversible defects in 31 patients (40%). Sensitivity, specificity, and negative and positive predictive values, respectively, of CT angiography in the detection of reversible myocardial perfusion imaging defects were 95%, 53%, 94%, and 58% on a per-patient basis and 95%, 75%, 96%, and 72% on a per-artery basis. Agreement between CT and conventional angiography was very good (96% and kappa = 0.92 for patient-based analysis, 93% and kappa = 0.84 for vessel-based analysis). CONCLUSION: Sixty-four-section CT angiography can help rule out hemodynamically relevant CAD in patients with intermediate to high pretest likelihood, although an abnormal CT angiography study is a poor predictor of ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to analyze and compare the value of fine-needle aspiration cytology (FNAC) and frozen section (FS) analysis in the assessment of parotid gland tumors. STUDY DESIGN: Chart review and cross-sectional analysis. SUBJECTS AND METHODS: FNAC and FS analysis of 110 parotid tumors, 68 malignancies and 42 benign tumors, were analyzed and compared with the final histopathologic diagnosis. RESULTS: The accuracy, sensitivity, and specificity of FNAC in detecting malignant tumors were 79 percent, 74 percent, and 88 percent, respectively. On FS analysis, the accuracy, sensitivity, and specificity in detecting malignant tumors were 94 percent, 93 percent, and 95 percent, respectively. The histologic tumor type was correctly diagnosed by FNAC and FS in 27 of 42 (64%) and 39 of 42 (93%) benign tumors, respectively, and in 24 of 68 (35%) and 49 of 68 (72%) malignant neoplasms, respectively. CONCLUSION: The current analysis showed a superiority of FS compared with FNAC regarding the diagnosis of malignancy and tumor typing. FNAC alone is not prone to determine the surgical management of parotid malignancies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A measurement of the total pp cross section at the LHC at √s = 7 TeV is presented. In a special run with high-β* beam optics, an integrated luminosity of 80 μb−1 was accumulated in order to measure the differential elastic cross section as a function of the Mandelstam momentum transfer variable t . The measurement is performed with the ALFA sub-detector of ATLAS. Using a fit to the differential elastic cross section in the |t | range from 0.01 GeV2 to 0.1 GeV2 to extrapolate to |t | →0, the total cross section, σtot(pp→X), is measured via the optical theorem to be: σtot(pp→X) = 95.35± 0.38 (stat.)± 1.25 (exp.)± 0.37 (extr.) mb, where the first error is statistical, the second accounts for all experimental systematic uncertainties and the last is related to uncertainties in the extrapolation to |t | → 0. In addition, the slope of the elastic cross section at small |t | is determined to be B = 19.73 ±0.14 (stat.) ±0.26 (syst.) GeV−2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The differential cross section for the process Z/√ → ℓℓ (ℓ = e, μ) as a function of dilepton invariant mass is measured in pp collisions at ps = 7TeV at the LHC using the ATLAS detector. The measurement is performed in the e and μ channels for invariant masses between 26 GeV and 66 GeV using an integrated luminosity of 1.6 fb−1 collected in 2011 and these measurements are combined. The analysis is extended to invariant masses as low as 12 GeV in the muon channel using 35 pb−1 of data collected in 2010. The cross sections are determined within fiducial acceptance regions and corrections to extrapolate the measurements to the full kinematic range are provided. Next-to-next-to-leading-order QCD predictions provide a significantly better description of the results than next-to-leadingorder QCD calculations, unless the latter are matched to a parton shower calculation.