24 resultados para Schelling, Friedrich Wilhelm Joseph von

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE A number of factors limit the effectiveness of current aortic arch studies in assessing optimal neuroprotection strategies, including insufficient patient numbers, heterogenous definitions of clinical variables, multiple technical strategies, inadequate reporting of surgical outcomes and a lack of collaborative effort. We have formed an international coalition of centres to provide more robust investigations into this topic. METHODS High-volume aortic arch centres were identified from the literature and contacted for recruitment. A Research Steering Committee of expert arch surgeons was convened to oversee the direction of the research. RESULTS The International Aortic Arch Surgery Study Group has been formed by 41 arch surgeons from 10 countries to better evaluate patient outcomes after aortic arch surgery. Several projects, including the establishment of a multi-institutional retrospective database, randomized controlled trials and a prospectively collected database, are currently underway. CONCLUSIONS Such a collaborative effort will herald a turning point in the surgical management of aortic arch pathologies and will provide better powered analyses to assess the impact of varying surgical techniques on mortality and morbidity, identify predictors for neurological and operative risk, formulate and validate risk predictor models and review long-term survival outcomes and quality-of-life after arch surgery.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

100.00% 100.00%

Publicador: