87 resultados para Satisfaction Measurement Methods
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Right ventricular (RV) systolic function is prognostically important, but its assessment by echocardiography remains challenging, in part because of the multitude of available measurement methods. The purpose of this prospective study was to rank these methods against the reference of RV ejection fraction (EF) as obtained in a broad clinical population by magnetic resonance imaging (MRI).
Resumo:
Several intervals have been proposed to quantify the agreement of two methods intended to measure the same quantity in the situation where only one measurement per method and subject is available. The limits of agreement are probably the most well-known among these intervals, which are all based on the differences between the two measurement methods. The different meanings of the intervals are not always properly recognized in applications. However, at least for small-to-moderate sample sizes, the differences will be substantial. This is illustrated both using the width of the intervals and on probabilistic scales related to the definitions of the intervals. In particular, for small-to-moderate sample sizes, it is shown that limits of agreement and prediction intervals should not be used to make statements about the distribution of the differences between the two measurement methods or about a plausible range for all future differences. Care should therefore be taken to ensure the correct choice of the interval for the intended interpretation.
Resumo:
BACKGROUND: Ankle-brachial pressure index (ABI) is a simple, inexpensive, and useful tool in the detection of peripheral arterial occlusive disease (PAD). The current guidelines published by the American Heart Association define ABI as the quotient of the higher of the systolic blood pressures (SBPs) of the two ankle arteries of that limb (either the anterior tibial artery or the posterior tibial artery) and the higher of the two brachial SBPs of the upper limbs. We hypothesized that considering the lower of the two ankle arterial SBPs of a side as the numerator and the higher of the brachial SBPs as the denominator would increase its diagnostic yield. METHODS: The former method of eliciting ABI was termed as high ankle pressure (HAP) and the latter low ankle pressure (LAP). ABI was assessed in 216 subjects and calculated according to the HAP and the LAP method. ABI findings were confirmed by arterial duplex ultrasonography. A significant arterial stenosis was assumed if ABI was <0.9. RESULTS: LAP had a sensitivity of 0.89 and a specificity of 0.93. The HAP method had a sensitivity of 0.68 and a specificity of 0.99. McNemar's test to compare the results of both methods demonstrated a two-tailed P < .0001, indicating a highly significant difference between both measurement methods. CONCLUSIONS: LAP is the superior method of calculating ABI to identify PAD. This result is of great interest for epidemiologic studies applying ABI measurements to detect PAD and assessing patients' cardiovascular risk.
Resumo:
BACKGROUND: Calcaneonavicular coalitions (CNC) have been reported to be associated with anatomical aberrations of either the calcaneus and/or navicular bones. These morphological abnormalities may complicate accurate surgical resection. Three-dimensional analysis of spatial orientation and morphological characteristics may help in preoperative planning of resection. MATERIALS AND METHODS: Sixteen feet with a diagnosis of CNC were evaluated by means of 3-D CT modeling. Three angles were defined that were expressed in relation to one reproducible landmark (lateral border of the calcaneus): the dorsoplantar inclination, anteroposterior inclination, and socket angle. The depth and width of the coalitions were measured and calculated to obtain the estimated contact surface. Three-dimensional reconstructions of the calcanei served to evaluate the presence, distortion or absence of the anterior calcaneal facet and presence of a navicular beak. The interrater correlations were assessed in order to obtain values for the accuracy of the measurement methods. Sixteen normal feet were used as controls for comparison of the socket angle; anatomy of the anterior calcaneal facet and navicular beak as well. RESULTS: The dorsoplantar inclination angle averaged 50 degrees (+/-17), the anteroposterior inclination angle 64 degrees (+/-15), and the pathologic socket angle 98 degrees (+/-11). The average contact area was 156 mm(2). Ninety-four percent of all patients in the CNC group revealed a plantar navicular beak. In 50% of those patients the anterior calcaneal facet was replaced by the navicular portion and in 44% the facet was totally missing. In contrast, the socket angle in the control group averaged 77 degrees (+/-18), which was found to be statistically different than the CNC group (p = 0.0004). Only 25% of the patients in the control group had a plantar navicular beak. High, statistically significant interrater correlations were found for all measured angles. CONCLUSION: Computer-aided CT analysis and reconstructions help to determine the spatial orientations of CNC in space and provide useful information in order to anticipate morphological abnormalities of the calcaneus and navicular.
Resumo:
INTRODUCTION AND HYPOTHESIS The prevalence of female stress urinary incontinence is high, and young adults are also affected, including athletes, especially those involved in "high-impact" sports. To date there have been almost no studies testing pelvic floor muscle (PFM) activity during dynamic functional whole body movements. The aim of this study was the description and reliability test of PFM activity and time variables during running. METHODS A prospective cross-sectional study including ten healthy female subjects was designed with the focus on the intra-session test-retest reliability of PFM activity and time variables during running derived from electromyography (EMG) and accelerometry. RESULTS Thirteen variables were identified based on ten steps of each subject: Six EMG variables showed good reliability (ICC 0.906-0.942) and seven time variables did not show good reliability (ICC 0.113-0.731). Time variables (e.g. time difference between heel strike and maximal acceleration of vaginal accelerator) showed low reliability. However, relevant PFM EMG variables during running (e.g., pre-activation, minimal and maximal activity) could be identified and showed good reliability. CONCLUSION Further adaptations regarding measurement methods should be tested to gain better control of the kinetics and kinematics of the EMG probe and accelerometers. To our knowledge this is the first study to test the reliability of PFM activity and time variables during dynamic functional whole body movements. More knowledge of PFM activity and time variables may help to provide a deeper insight into physical strain with high force impacts and important functional reflexive contraction patterns of PFM to maintain or to restore continence.
Resumo:
This study compares the performance of four commonly used approaches to measure consumers’ willingness to pay with real purchase data (REAL): the open-ended (OE) question format; choicebased conjoint (CBC) analysis; Becker, DeGroot, and Marschak’s (BDM) incentive-compatible mechanism; and incentive-aligned choice-based conjoint (ICBC) analysis. With this five-in-one approach, the authors test the relative strengths of the four measurement methods, using REAL as the benchmark, on the basis of statistical criteria and decision-relevant metrics. The results indicate that the BDM and ICBC approaches can pass statistical and decision-oriented tests. The authors find that respondents are more price sensitive in incentive-aligned settings than in non-incentive-aligned settings and the REAL setting. Furthermore, they find a large number of “none” choices under ICBC than under hypothetical conjoint analysis. This study uncovers an intriguing possibility: Even when the OE format and CBC analysis generate hypothetical bias, they may still lead to the right demand curves and right pricing decisions.
Resumo:
AIMS A better understanding of pelvic floor muscle (PFM) activation and strength components is a prerequisite to get better insight in PFM contraction mechanisms and develop more specific PFM-training regimens for female stress urinary incontinence (SUI) patients. The aim of this systematic review (2012:CRD42012002547) was to evaluate and summarize existing studies investigating PFM activation and strength components influencing female continence and SUI. METHODS PubMed, EMBASE, and Cochrane databases were systematically searched for literature from January 1980 to November 2013 for cross-sectional studies comparing female SUI patients with healthy controls and intervention studies with SUI patients reporting on the association between PFM activation and strength components and urine loss. Trial characteristics, evaluated PFM components, their definitions, measurement methods, study outcomes, as well as quality measures, based on the Cochrane risk of bias tool, were independently extracted. The high heterogeneity of the retrieved data made pooling of results impossible and therefore restricted the analysis to a systematic review. RESULTS Cross-sectional studies showed group differences in favor of the continent women compared to SUI patients for PFM activation or PFM maximal strength, mean strength or sustained contraction. All intervention studies showed an improvement of PFM strength and decrease in urine loss in SUI patients after physical therapy. CONCLUSIONS Higher PFM activation and strength components influence female continence positively. This systematic review underscored the need for a standardized PFM components' terminology (similar to rehabilitation and training science), standardized test procedures and well matched diagnostic instruments. Neurourol. Urodynam. © 2014 Wiley Periodicals, Inc.
Resumo:
The Microwave Emission Model of Layered Snowpacks (MEMLS) was originally developed for microwave emissions of snowpacks in the frequency range 5–100 GHz. It is based on six-flux theory to describe radiative transfer in snow including absorption, multiple volume scattering, radiation trapping due to internal reflection and a combination of coherent and incoherent superposition of reflections between horizontal layer interfaces. Here we introduce MEMLS3&a, an extension of MEMLS, which includes a backscatter model for active microwave remote sensing of snow. The reflectivity is decomposed into diffuse and specular components. Slight undulations of the snow surface are taken into account. The treatment of like- and cross-polarization is accomplished by an empirical splitting parameter q. MEMLS3&a (as well as MEMLS) is set up in a way that snow input parameters can be derived by objective measurement methods which avoid fitting procedures of the scattering efficiency of snow, required by several other models. For the validation of the model we have used a combination of active and passive measurements from the NoSREx (Nordic Snow Radar Experiment) campaign in Sodankylä, Finland. We find a reasonable agreement between the measurements and simulations, subject to uncertainties in hitherto unmeasured input parameters of the backscatter model. The model is written in Matlab and the code is publicly available for download through the following website: http://www.iapmw.unibe.ch/research/projects/snowtools/memls.html.
Resumo:
INTRODUCTION Investigations of the dynamic function of female pelvic floor muscles (PFM) help us to understand the pathophysiology of stress urinary incontinence (SUI). Displacement measurements of PFM give insight into muscle activation and thus help to improve rehabilitation strategies. This systematic review (PROSPERO 2013: CRD42013006409) was performed to summarise the current evidence for PFM displacement during voluntary and involuntary activation in continent and incontinent women. METHODS MEDLINE, EMBASE, Cochrane and SPORTDiscus databases were searched using selected terminology reflecting the PICO approach. Screening of Google Scholar and congress abstracts added to further information. Original articles investigating PFM displacement were included if they reported on at least one of the aims of the review, e.g., method, test position, test activity, direction and quantification of displacement, as well as the comparison between continent and incontinent women. Titles and abstracts were screened by two reviewers. The papers included were reviewed by two individuals to ascertain whether they fulfilled the inclusion criteria and data were extracted on outcome parameters. RESULTS Forty-two predominantly observational studies fulfilled the inclusion criteria. A variety of measurement methods and calculations of displacement was presented. The sample was heterogeneous concerning age, parity and continence status. Test positions and test activities varied among the studies. CONCLUSIONS The findings summarise the present knowledge of PFM displacement, but still lack deeper comprehension of the SUI pathomechanism of involuntary, reflexive activation during functional activities. We therefore propose that future investigations focus on PFM dynamics during fast and stressful impact tasks.
Resumo:
The advantages, limitations and potential applications of available methods for studying erosion of enamel and dentine are reviewed. Special emphasis is placed on the influence of histological differences between the dental hard tissue and the stage of the erosive lesion. No method is suitable for all stages of the lesion. Factors determining the applicability of the methods are: surface condition of the specimen, type of the experimental model, nature of the lesion, need for longitudinal measurements and type of outcome. The most suitable and most widely used methods are: chemical analyses of mineral release and enamel surface hardness for early erosion, and surface profilometry and microradiography for advanced erosion. Morphological changes in eroded dental tissue have usually been characterised by scanning electron microscopy. Novel methods have also been used, but little is known of their potential and limitations. Therefore, there is a need for their further development, evaluation, consolidation and, in particular, validation.
Resumo:
Because of the important morbidity and mortality associated with osteoporosis, it is essential to detect subjects at risk by screening methods, such as bone quantitative ultrasounds (QUSs). Several studies showed that QUS could predict fractures. None, however, compared prospectively different QUS devices, and few data of quality controls (QCs) have been published. The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk is a prospective multicenter study that compared three QUSs for the assessment of hip fracture risk in a population of 7609 women age >/=70 yr. Because the inclusion phase lasted 20 mo, and because 10 centers participated in this study, QC became a major issue. We therefore developed a QC procedure to assess the stability and precision of the devices, and for their cross-calibration. Our study focuses on the two heel QUSs. The water bath system (Achilles+) had a higher precision than the dry system (Sahara). The QC results were highly dependent on temperature. QUS stability was acceptable, but Sahara must be calibrated regularly. A sufficient homogeneity among all the Sahara devices could be demonstrated, whereas significant differences were found among the Achilles+ devices. For speed of sound, 52% of the differences among the Achilles+ was explained by the water s temperature. However, for broadband ultrasound attenuation, a maximal difference of 23% persisted after adjustment for temperature. Because such differences could influence measurements in vivo, it is crucial to develop standardized phantoms to be used in prospective multicenter studies.
Resumo:
This study analyzed the influence of the occupational context on the conceptualization of career satisfaction measured by the career satisfaction scale (CSS). In a large sample of N ¼ 729 highly educated professionals, a cross-occupational (i.e., physicians, economists, engineers, and teachers) measurement invariance analysis showed that the CSS was conceptualized according to occupational group membership, that is, 4 of the 5 items of the scale showed measurement noninvariance. More specifically, the relative importance, the response biases, and the reliabilities associated with different career satisfaction content domains measured by the CSS (i.e., achieved success, overall career goals, goals for advancement, goals for income, and goals for development of new skills) varied by occupational context. However, results of a comparison between manifest and latent mean differences between the occupational groups revealed that the observed measurement noninvariance did not affect the estimation of mean differences.
Resumo:
The present research analyses the adequacy of the widely used Career Satisfaction Scale (CSS; Greenhaus, Parasuraman, & Wormley, 1990) for measuring change over time. We used data of a sample of 1,273 professionals over a 5-year time period. First, we tested longitudinal measurement invariance of the CSS. Second, we analysed changes in career satisfaction by means of multiple indicator latent growth modelling (MLGM). Results revealed that the CSS can be reliably used in mean change analyses. Altogether, career satisfaction was relatively stable over time; however, we found significant variance in intra-individual growth trajectories and a negative correlation between the initial level of and changes in career satisfaction. Professionals who were initially highly satisfied became less satisfied over time. Theoretical and practical implications with respect to the construct of career satisfaction and its development over time (i.e., alpha, beta, and gamma change) are discussed.