7 resultados para Sang périphérique
em BORIS: Bern Open Repository and Information System - Berna - Suiça
«Vers une transculturalité mondialisée. Wajdi Mouawad : Le Sang des promesses, marges et frontières»
Resumo:
Tandis que nombre d’anthropologues ont critiqué les apories du multiculturalisme canadien, lequel prétend ouvrir à une politique de la «reconnaissance», cet article envisage comment la «reconnaissance» gagne à être envisagée au niveau «transculturel», et comment une telle reconnaissance transculturelle peut être figurée dans une dramaturgie fondée sur un renouvellement de la reconnaissance (anagnôrisis) aristotélicienne.
Resumo:
Conférence donnée dans le cadre du Séminaire doctoral «Marges et passages», Université Lumière Lyon 2, 15 mars 2014.
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.
Resumo:
Mucous membrane pemphigoid encompasses a group of autoimmune bullous diseases with a similar phenotype characterized by subepithelial blisters, erosions, and scarring of mucous membranes, skin, or both. Although knowledge about autoimmune bullous disease is increasing, there is often a lack of clear definitions of disease, outcome measures, and therapeutic end points. With clearer definitions and outcome measures, it is possible to directly compare the results and data from various studies using meta-analyses. This consensus statement provides accurate and reproducible definitions for disease extent, activity, outcome measures, end points, and therapeutic response for mucous membrane pemphigoid and proposes a disease extent score, the Mucous Membrane Pemphigoid Disease Area Index.