5 resultados para Salix X sepulcralis extract
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.
Resumo:
BACKGROUND: Equine sarcoids (ES) are common, difficult to treat, and have high recurrence rates. Viscum album extracts (VAE) are used in human cancer treatment. HYPOTHESIS: That therapy with VAE (Iscador P) is effective in the treatment of ES. ANIMALS: Fifty-three horses (444 ES); 42 were treated with VAE or placebo as monotherapy; 11 were treated with VAE or placebo after selective excision of ES. METHODS: Prospective, randomised, blinded, clinical trial. Horses were randomly assigned to treatment (VAE; n=32) or control group (Placebo; n=21). One milliliter of VAE (Iscador P) in increasing concentrations from 0.1 to 20 mg/mL or physiological NaCl solution was given SC 3 times a week over 105 days. Number, localization, and type of the ES were documented over 12 months. A subset of 163 clinically diagnosed equine sarcoid (CDES) lesions (95 VAE, 68 Placebo) was evaluated in detail, considering clinical findings and tumor volume. RESULTS: No undesired adverse effects were observed except for mild edema at the injection site in 5 of 32 horses (16%). Complete or partial regression was observed in 13 horses of the VAE group (41%) and in 3 of the control horses (14%; P<.05). After VAE treatment, 48 of 95 CDES (67%) showed an improvement compared with 17 of 68 CDES in the control group (40%; P<.01). Twenty-seven CDES had disappeared completely in the VAE group (38%) compared with 9 CDES in the control group (13% NS). CONCLUSIONS AND CLINICAL IMPORTANCE: VAE (Iscador P) represents a safe and effective treatment for CDES.
Resumo:
The small trees of gas-exchanging pulmonary airways which are fed by the most distal purely conducting airways are called acini and represent the functional gas-exchanging units. The three-dimensional architecture of the acini has a strong influence on ventilation and particle deposition. Due to the difficulty to identify individual acini on microscopic lung sections the knowledge about the number of acini and their biological parameters like volume, surface area, and number of alveoli per acinus are limited. We developed a method to extract individual acini from lungs imaged by high-resolution synchrotron radiation based X-ray tomographic microscopy and estimated their volume, surface area and number of alveoli. Rat acini were isolated by semiautomatically closing the airways at the transition from conducting to gas-exchanging airways. We estimated a mean internal acinar volume of 1.148mm(3), a mean acinar surface area of 73.9mm(2), and a mean of 8470 alveoli per acinus. Assuming that the acini are similarly sized throughout different regions of the lung, we calculated that a rat lung contains 5470±833 acini. We conclude that our novel approach is well suited for the fast and reliable characterization of a large number of individual acini in healthy, diseased, or transgenic lungs of different species including humans.
Resumo:
In the present study the challenge of analyzing complex micro X-ray diffraction (microXRD) patterns from cement–clay interfaces has been addressed. In order to extract the maximum information concerning both the spatial distribution and the crystal structure type associated with each of the many diffracting grains in heterogeneous, polycrystalline samples, an approach has been developed in which microXRD was applied to thin sections which were rotated in the X-ray beam. The data analysis, performed on microXRD patterns collected from a filled vein of a cement–clay interface from the natural analogue in Maqarin (Jordan), and a sample from a two-year-old altered interface between cement and argillaceous rock, demonstrate the potential of this method.
Resumo:
X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.