26 resultados para Safety-critical software

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper reviews the methods, benefits and challenges associated with the adoption and translation of computational fluid dynamics (CFD) modelling within cardiovascular medicine. CFD, a specialist area of mathematics and a branch of fluid mechanics, is used routinely in a diverse range of safety-critical engineering systems, which increasingly is being applied to the cardiovascular system. By facilitating rapid, economical, low-risk prototyping, CFD modelling has already revolutionised research and development of devices such as stents, valve prostheses, and ventricular assist devices. Combined with cardiovascular imaging, CFD simulation enables detailed characterisation of complex physiological pressure and flow fields and the computation of metrics which cannot be directly measured, for example, wall shear stress. CFD models are now being translated into clinical tools for physicians to use across the spectrum of coronary, valvular, congenital, myocardial and peripheral vascular diseases. CFD modelling is apposite for minimally-invasive patient assessment. Patient-specific (incorporating data unique to the individual) and multi-scale (combining models of different length- and time-scales) modelling enables individualised risk prediction and virtual treatment planning. This represents a significant departure from traditional dependence upon registry-based, population-averaged data. Model integration is progressively moving towards 'digital patient' or 'virtual physiological human' representations. When combined with population-scale numerical models, these models have the potential to reduce the cost, time and risk associated with clinical trials. The adoption of CFD modelling signals a new era in cardiovascular medicine. While potentially highly beneficial, a number of academic and commercial groups are addressing the associated methodological, regulatory, education- and service-related challenges.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A systematic literature review was conducted to assess the effectiveness of, compliance with, and critical factors for the implementation of safety checklists in surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In 2005 the Swiss government implemented new work-hour limitations for all residency programs in Switzerland, including a 50-hour weekly limit. The reduction in the working hours of doctors in training implicate an increase in their rest time and suggest an amelioration of doctors' clinical performance and consequently in patients' outcomes and safety - which was not detectable in a preliminary study at a large referral center in Switzerland. It remains elusive why work-hour restrictions did not improve patient safety. We are well advised to thoroughly examine and eliminate the known adverse effects of reduced work-hours to improve our patients' safety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Physiologic data display is essential to decision making in critical care. Current displays echo first-generation hemodynamic monitors dating to the 1970s and have not kept pace with new insights into physiology or the needs of clinicians who must make progressively more complex decisions about their patients. The effectiveness of any redesign must be tested before deployment. Tools that compare current displays with novel presentations of processed physiologic data are required. Regenerating conventional physiologic displays from archived physiologic data is an essential first step. OBJECTIVES: The purposes of the study were to (1) describe the SSSI (single sensor single indicator) paradigm that is currently used for physiologic signal displays, (2) identify and discuss possible extensions and enhancements of the SSSI paradigm, and (3) develop a general approach and a software prototype to construct such "extended SSSI displays" from raw data. RESULTS: We present Multi Wave Animator (MWA) framework-a set of open source MATLAB (MathWorks, Inc., Natick, MA, USA) scripts aimed to create dynamic visualizations (eg, video files in AVI format) of patient vital signs recorded from bedside (intensive care unit or operating room) monitors. Multi Wave Animator creates animations in which vital signs are displayed to mimic their appearance on current bedside monitors. The source code of MWA is freely available online together with a detailed tutorial and sample data sets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Critical incident reporting alone does not necessarily improve patient safety or even patient outcomes. Substantial improvement has been made by focusing on the further two steps of critical incident monitoring, that is, the analysis of critical incidents and implementation of system changes. The system approach to patient safety had an impact on the view about the patient's role in safety. This review aims to analyse recent advances in the technique of reporting, the analysis of reported incidents, and the implementation of actual system improvements. It also explores how families should be approached about safety issues. RECENT FINDINGS: It is essential to make as many critical incidents as possible known to the intensive care team. Several factors have been shown to increase the reporting rate: anonymity, regular feedback about the errors reported, and the existence of a safety climate. Risk scoring of critical incident reports and root cause analysis may help in the analysis of incidents. Research suggests that patients can be successfully involved in safety. SUMMARY: A persisting high number of reported incidents is anticipated and regarded as continuing good safety culture. However, only the implementation of system changes, based on incident reports, and also involving the expertise of patients and their families, has the potential to improve patient outcome. Hard outcome criteria, such as standardized mortality ratio, have not yet been shown to improve as a result of critical incident monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peripheral artery disease is a progressive disease. Primary ischemic leg symptoms are muscle fatigue, discomfort or pain during ambulation, known as intermittent claudication. The most severe manifestation of peripheral artery disease is critical limb ischemia (CLI). The long-term safety of gene therapy in peripheral artery disease remains unclear. This four center peripheral artery disease registry was designed to evaluate the long-term safety of the intramuscular non-viral fibroblast growth factor-1 (NV1FGF), a plasmid-based angiogenic gene for local expression of fibroblast growth factor-1 versus placebo in patients with peripheral artery disease who had been included in five different phase I and II trials. Here we report a 3-year follow-up in patients suffering from CLI or intermittent claudication. There were 93 evaluable patients, 72 of them in Fontaine stage IV (47 NV1FGF versus 25 placebo) and 21 patients in Fontaine stage IIb peripheral artery disease (15 NV1FGF versus 6 placebo). Safety parameters included rates of non-fatal myocardial infarction (MI), stroke, death, cancer, retinopathy and renal dysfunction. At 3 years, in 93 patients included this registry, there was no increase in retinopathy or renal dysfunction associated with delivery of this angiogenic factor. There was also no difference in the number of strokes, MI or deaths, respectively, for NV1FGF versus placebo. In the CLI group, new cancer occurred in two patients in the NV1FGF group. Conclusions that can be drawn from this relatively small patient group are limited because of the number of patients followed and can only be restricted to safety. Yet, data presented may be valuable concerning rates in cancer, retinopathy, MI or strokes following angiogenesis gene therapy in the absence of any long-term data in angiogenesis gene therapy. It may take several years until data from larger patient populations will become available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In her book 'Living on Light', Jasmuheen tries to animate people worldwide to follow her drastic nutrition rules in order to boost their quality of life. Several deaths have been reported as a fatal consequence. A doctor of chemistry who believably claimed to have been 'living on light' for 2 years, except for the daily intake of up to 1.5 l of fluid containing no or almost no calories was interested in a scientific study on this phenomenon. PARTICIPANT AND METHODS: The 54-year-old man was subjected to a rigorous 10-day isolation study with complete absence of nutrition. During the study he obtained an unlimited amount of tea and mineral water but had no caloric intake. Parameters to monitor his metabolic and psychological state and vital parameters were measured regularly and the safety of the individual was ensured throughout the study. The subject agreed on these terms and the study was approved by the local ethics committee.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the efficacy and safety of intramuscular administration of NV1FGF, a plasmid-based angiogenic gene delivery system for local expression of fibroblast growth factor 1 (FGF-1), versus placebo, in patients with critical limb ischemia (CLI). In a double-blind, randomized, placebo-controlled, European, multinational study, 125 patients in whom revascularization was not considered to be a suitable option, presenting with nonhealing ulcer(s), were randomized to receive eight intramuscular injections of placebo or 2.5 ml of NV1FGF at 0.2 mg/ml on days 1, 15, 30, and 45 (total 16 mg: 4 x 4 mg). The primary end point was occurrence of complete healing of at least one ulcer in the treated limb at week 25. Secondary end points included ankle brachial index (ABI), amputation, and death. There were 107 patients eligible for evaluation. Improvements in ulcer healing were similar for use of NV1FGF (19.6%) and placebo (14.3%; P = 0.514). However, the use of NV1FGF significantly reduced (by twofold) the risk of all amputations [hazard ratio (HR) 0.498; P = 0.015] and major amputations (HR 0.371; P = 0.015). Furthermore, there was a trend for reduced risk of death with the use of NV1FGF (HR 0.460; P = 0.105). The adverse event incidence was high, and similar between the groups. In patients with CLI, plasmid-based NV1FGF gene transfer was well tolerated, and resulted in a significantly reduced risk of major amputation when compared with placebo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To test the feasibility of and interactions among three software-driven critical care protocols. DESIGN: Prospective cohort study. SETTING: Intensive care units in six European and American university hospitals. PATIENTS: 174 cardiac surgery and 41 septic patients. INTERVENTIONS: Application of software-driven protocols for cardiovascular management, sedation, and weaning during the first 7 days of intensive care. MEASUREMENTS AND RESULTS: All protocols were used simultaneously in 85% of the cardiac surgery and 44% of the septic patients, and any one of the protocols was used for 73 and 44% of study duration, respectively. Protocol use was discontinued in 12% of patients by the treating clinician and in 6% for technical/administrative reasons. The number of protocol steps per unit of time was similar in the two diagnostic groups (n.s. for all protocols). Initial hemodynamic stability (a protocol target) was achieved in 26+/-18 min (mean+/-SD) in cardiac surgery and in 24+/-18 min in septic patients. Sedation targets were reached in 2.4+/-0.2h in cardiac surgery and in 3.6 +/-0.2h in septic patients. Weaning protocol was started in 164 (94%; 154 extubated) cardiac surgery and in 25 (60%; 9 extubated) septic patients. The median (interquartile range) time from starting weaning to extubation (a protocol target) was 89 min (range 44-154 min) for the cardiac surgery patients and 96 min (range 56-205 min) for the septic patients. CONCLUSIONS: Multiple software-driven treatment protocols can be simultaneously applied with high acceptance and rapid achievement of primary treatment goals. Time to reach these primary goals may provide a performance indicator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To review trial design issues related to control groups. DESIGN: Review of the literature with specific reference to critical care trials. MAIN RESULTS AND CONCLUSIONS: Performing randomized controlled trials in the critical care setting presents specific problems: studies include patients with rapidly lethal conditions, the majority of intensive care patients suffer from syndromes rather than from well-definable diseases, the severity of such syndromes cannot be precisely assessed, and the treatment consists of interacting therapies. Interactions between physiology, pathophysiology, and therapies are at best marginally understood and may have a major impact on study design and interpretation of results. Selection of the right control group is crucial for the interpretation and clinical implementation of results. Studies comparing new interventions with current ones or different levels of current treatments have the problem of the necessity of defining "usual care." Usual care controls without any constraints typically include substantial heterogeneity. Constraints in the usual therapy may help to reduce some variation. Inclusion of unrestricted usual care groups may help to enhance safety. Practice misalignment is a novel problem in which patients receive a treatment that is the direct opposite of usual care, and occurs when fixed-dose interventions are used in situations where care is normally titrated. Practice misalignment should be considered in the design and interpretation of studies on titrated therapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: Meta-analyses are an essential tool of clinical research. Meta-analyses of individual randomized controlled trials frequently constitute the highest possible level of scientific evidence for a given research question and allow surgeons to rapidly gain a comprehensive understanding of an important clinical issue. Moreover, meta-analyses often serve as cornerstones for evidence-based surgery, treatment guidelines, and knowledge transfer. Given the importance of meta-analyses to the medical (and surgical) knowledge base, it is of cardinal importance that surgeons have a basic grasp of the principles that guide a high-quality meta-analysis, and be able to weigh objectively the advantages and potential pitfalls of this clinical research tool. Unfortunately, surgeons are often ill-prepared to successfully conduct, critically appraise, and correctly interpret meta-analyses. The objective of this educational review is to provide surgeons with a brief introductory overview of the knowledge and skills required for understanding and critically appraising surgical meta-analyses as well as assessing their implications for their own surgical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Critical incidents in clinical medicine can have far-reaching consequences on patient health. In cases of severe medical errors they can seriously harm the patient or even lead to death. The involvement in such an event can result in a stress reaction, a so-called acute posttraumatic stress disorder in the healthcare provider, the so-called second victim of an adverse event. Psychological distress may not only have a long lasting impact on quality of life of the physician or caregiver involved but it may also affect the ability to provide safe patient care in the aftermath of adverse events. METHODS A literature review was performed to obtain information on care giver responses to medical errors and to determine possible supportive strategies to mitigate negative consequences of an adverse event on the second victim. An internet search and a search in Medline/Pubmed for scientific studies were conducted using the key words "second victim, "medical error", "critical incident stress management" (CISM) and "critical incident stress reporting system" (CIRS). Sources from academic medical societies and public institutions which offer crisis management programs where analyzed. The data were sorted by main categories and relevance for hospitals. Analysis was carried out using descriptive measures. RESULTS In disaster medicine and aviation navigation services the implementation of a CISM program is an efficient intervention to help staff to recover after a traumatic event and to return to normal functioning and behavior. Several other concepts for a clinical crisis management plan were identified. CONCLUSIONS The integration of CISM and CISM-related programs in a clinical setting may provide efficient support in an acute crisis and may help the caregiver to deal effectively with future error events and employee safety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To provide a brief introduction into Critical Incident Reporting Systems (CIRS) as used in human medicine, and to report the discussion from a recent panel meeting discussion with 23 equine anaesthetists in preparation for a new CEPEF-4 (Confidential Enquiry into Perioperative Equine Fatalities) study. STUDY DESIGN Moderated group discussions, and review of literature. METHODS The first group discussion focused on the definition of 'preventable critical incidents' and/or 'near misses' in the context of equine anaesthesia. The second group discussion focused on categorizing critical incidents according to an established framework for analysing risk and safety in clinical medicine. RESULTS While critical incidents do occur in equine anaesthesia, no critical incident reporting system including systematic collection and analysis of critical incidents is in place. CONCLUSIONS AND CLINICAL RELEVANCE Critical incident reporting systems could be used to improve safety in equine anaesthesia - in addition to other study types such as mortality studies.