4 resultados para Safety values

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cystic fibrosis (CF) is characterized by chronic bacterial broncho-pulmonary infection. Although intravenous (IV) antibiotic therapy is regarded as standard treatment in CF, only few randomised trials comparing different antibiotic compounds exist. METHODS: We report on a prospective multicenter interventional trial of IV meropenem (120 mg/kg/day) or IV ceftazidime (200-400 mg/kg/day), each administered together with IV tobramycin (9-12 mg/kg/day). Outcome measures were changes in lung function, microbiological sputum burden and blood inflammatory marker. Liver and renal function values were measured to assess safety. RESULTS: One hundred eighteen patients (59/59) were included into the study with the following indications: first infection of P. aeruginosa (n=6), acute pulmonary exacerbation (n=34) and suppression therapy of chronic P. aeruginosa colonization (n=78). Both treatments improved lung function measures, bacterial sputum burden and CRP levels with no differences between treatment groups observed. A significant higher elevation for alkaline phosphatase (p<0.0001) was observed for patients in the meropenem/tobramycin group. CONCLUSIONS: IV antibiotic therapy in CF patients with meropenem/tobramycin is as effective as with ceftazidime/tobramycin regarding lung function, microbiological sputum burden and systemic inflammatory status. Hepato-biliary function should be monitored carefully during IV treatment, possibly important in CF patients with pre-existing liver disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The primary purpose of the clinical trial was to assess the safety and efficacy of once-a-day compared with three-times-a-day gentamicin in patients with serious infections who had protocol-determined peak serum aminoglycoside concentrations. PATIENTS AND METHODS: A total of 249 hospitalized patients with suspected or proven serious infections were randomized in a 2:2:1 ratio to gentamicin given three times a day with ticarcillin-clavulanate (TC), gentamicin once a day with TC, or ticarcillin-clavulanate (TC) alone. The gentamicin once-a-day dosage for patients with estimated creatinine clearance values of > or =80 mL/min was 5.1 mg/kg. With lower creatinine clearance estimates, the mg/kg dosage of gentamicin was decreased, and the dosage intervals (once daily or three times a day) were maintained. Evaluability required documentation of achievement of protocol-defined peak serum gentamicin levels. RESULTS: Of the total 175 evaluable patients, there were no significant differences found between treatment regimens with respect to clinical or microbiologic efficacy. Bedside audiometry proved impractical due to the frequency of altered mental state in ill patients. Based on the traditional increase in serum creatinine values from baseline values, no differences in renal toxicity between the treatment groups was identified. When changes in renal function were reanalyzed based on maintaining, as opposed to worsening, of renal function, preservation of renal function was better in the gentamicin once-a-day patients as opposed to the gentamicin three-times-a-day patients, P <0.01. CONCLUSIONS: Gentamicin once a day plus TC, gentamicin three times a day plus TC, and TC alone had similar effects in seriously ill hospitalized patients. The incidence of nephrotoxicity was similar in the three treatment groups. Using a nonvalidated post-hoc analysis, renal function was better preserved in gentamicin once-a-day + TC and TC-only patients as opposed to gentamicin three-times-a-day + TC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE, AIMS AND OBJECTIVES Safety climate measurements are a broadly used element of improvement initiatives. In order to provide a sound and easy-to-administer instrument for the use in Swiss hospitals, we translated the Safety Climate Survey into German and French. METHODS After translating the Safety Climate Survey into French and German, a cross-sectional survey study was conducted with health care professionals (HCPs) in operating room (OR) teams and on OR-related wards in 10 Swiss hospitals. Validity of the instrument was examined by means of Cronbach's alpha and missing rates of the single items. Item-descriptive statistics group differences and percentage of 'problematic responses' (PPR) were calculated. RESULTS 3153 HCPs completed the survey (response rate: 63.4%). 1308 individuals were excluded from the analyses because of a profession other than doctor or nurse or invalid answers (n = 1845; nurses = 1321, doctors = 523). Internal consistency of the translated Safety Climate Survey was good (Cronbach's alpha G erman  = 0.86; Cronbach's alpha F rench  = 0.84). Missing rates at item level were rather low (0.23-4.3%). We found significant group differences in safety climate values regarding profession, managerial function, work area and time spent in direct patient care. At item level, 14 out of 21 items showed a PPR higher than 10%. CONCLUSIONS Results indicate that the French and German translations of the Safety Climate Survey might be a useful measurement instrument for safety climate in Swiss hospital units. Analyses at item level allow for differentiating facets of safety climate into more positive and critical safety climate aspects.