12 resultados para Runge-kutta

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rotavirus (RV) is a frequent cause of severe gastroenteritis (GE) in children. With the licensure of new RV vaccines, data on the burden of disease are important regarding immunization strategies. We reviewed the medical records of children hospitalized with RV infection in our institution between July 2002 and March 2006. Relevant data were extracted in a standardized fashion from records of hospitalized children with a positive RV antigen test in a stool sample. Severity of disease was graded by the 20-point Vesikari score. Population data were obtained from the Federal Office of Statistics. Six hundred eighty-six RVGE were identified and records of 608 hospitalizations (in 607 children) were available. In 539 (89%) cases, RVGE was the primary reason for hospitalization and 69 (11%) were nosocomial infections; yearly peaks occurred between February and May. Cumulative incidence of RVGE was 26.7/1,000 children <3 years of age. Median age of 539 children (55.6% male) with primary RVGE was 1.4 years and median stay in the hospital for both community acquired and nosocomial RVGE was 4 days (interquartile range 3-5). Thirtypercent and 94% of RV hospitalizations were in children <1 and <3 years of age, respectively. Mean Vesikari score was 15 (range 6-20; 96% >11). Intravenous fluids were administered in 378 (70%) patients, 130 (24%) patients were rehydrated via nasogastral tube, and 31 (5.7%) received rehydration by mouth. RVGE causes a substantial burden in children with an estimated risk for hospitalization due to RVGE of one in 37 children <3 years of age.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retroperitoneal location of bronchogenic cysts is extremely rare. Most commonly they are encountered in the posterior mediastinum. Bronchogenic cysts arise from developmental aberrations of the tracheobronchial tree in the early embryologic period. We report a 42-year-old female patient with a retroperitoneal bronchogenic cyst in the left adrenal region. She was admitted to our hospital with epigastric pain and subsequently underwent CT of the abdomen. The examination revealed a mass related to the left adrenal gland. Endocrine tests for adrenal hypersecretion were negative. Because of the uncertain entity, laparoscopic adrenalectomy was performed. Pathological examination revealed a bronchogenic cyst in proximity to an inconspicuous left adrenal gland. Although very rare, bronchogenic cysts should be considered in the differential diagnosis of retroperitoneal cystic lesions and surgical resection pursued for symptom resolution and to establish a definitive histology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Chylothorax is an extremely rare but potentially life-threatening complication after radical neck dissection. We report the case of a bilateral chylothorax after total thyroidectomy and cervico-central and cervico-lateral lymphadenectomy for thyroid carcinoma. CASE PRESENTATION A 40-year-old European woman underwent total thyroidectomy and neck dissection for papillary thyroid carcinoma. Postoperatively she developed dyspnoea and pleural effusion. A chylothorax was found and the initial conservative therapy was not successful. She had to be operated on again and the thoracic duct was legated. CONCLUSION The case presentation reports a very rare complication after total thyroidectomy and neck dissection, but it has to be kept in mind to prevent dangerous complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Readout-segmented echo planar imaging (rs-EPI) significantly reduces susceptibility artifacts in diffusion-weighted imaging (DWI) of the breast compared to single-shot EPI but is limited by longer scan times. To compensate for this, we tested a new simultaneous multi-slice (SMS) acquisition for accelerated rs-EPI. MATERIALS AND METHODS After approval by the local ethics committee, eight healthy female volunteers (age, 38.9±13.1 years) underwent breast MRI at 3T. Conventional as well as two-fold (2× SMS) and three-fold (3× SMS) slice-accelerated rs-EPI sequences were acquired at b-values of 50 and 800s/mm(2). Two independent readers analyzed the apparent diffusion coefficient (ADC) in fibroglandular breast parenchyma. The signal-to-noise ratio (SNR) was estimated based on the subtraction method. ADC and SNR were compared between sequences by using the Friedman test. RESULTS The acquisition time was 4:21min for conventional rs-EPI, 2:35min for 2× SMS rs-EPI and 1:44min for 3× SMS rs-EPI. ADC values were similar in all sequences (mean values 1.62×10(-3)mm(2)/s, p=0.99). Mean SNR was 27.7-29.6, and no significant differences were found among the sequences (p=0.83). CONCLUSION SMS rs-EPI yields similar ADC values and SNR compared to conventional rs-EPI at markedly reduced scan time. Thus, SMS excitation increases the clinical applicability of rs-EPI for DWI of the breast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.