21 resultados para Rumble strip

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of a semiquantitative commercially available test based on DNA-strip technology (microIDent®, Hain Lifescience, Nehren, Germany) on diagnosis and treatment of severe chronic periodontitis of 25 periodontitis patients was evaluated in comparison with a quantitative in-house real-time PCR. Subgingival plaque samples were collected at baseline as well as at 3, 6, and 12 months later. After extracting DNA, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and several other periodontopathogens were determined by both methods. The results obtained by DNA-strip technology were analyzed semiquantitatively and additionally quantitatively by densitometry. The results for the 4 major periodontopathogenic bacterial species correlated significantly between the 2 methods. Samples detecting a high bacterial load by one method and negative by the other were always found in less than 2% of the total samples. Both technologies showed the impact of treatment on microflora. Especially the semiquantitative DNA-strip technology clearly analyzed the different loads of periodontopathogens after therapy and is useful in microbial diagnostics for patients in dental practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION In this in-vitro study, we aimed to investigate the predictability of the expected amount of stripping using 3 common stripping devices on premolars. METHODS One hundred eighty extracted premolars were mounted and aligned in silicone. Tooth mobility was tested with Periotest (Medizintechnik Gulden, Modautal, Germany) (8.3 ± 2.8 units). The selected methods for interproximal enamel reduction were hand-pulled strips (Horico, Hapf Ringleb & Company, Berlin, Germany), oscillating segmental disks (O-drive-OD 30; KaVo Dental, Biberach, Germany), and motor-driven abrasive strips (Orthofile; SDC Switzerland, Lugano-Grancia, Switzerland). With each device, the operator intended to strip 0.1, 0.2, 0.3, or 0.4 mm on the mesial side of 15 teeth. The teeth were scanned before and after stripping with a 3-dimensional laser scanner. Superposition and measurement of stripped enamel on the most mesial point of the tooth were conducted with Viewbox software (dHal Software, Kifissia, Greece). The Wilcoxon signed rank test and the Kruskal-Wallis test were applied; statistical significance was set at alpha ≤ 0.05. RESULTS Large variations between the intended and the actual amounts of stripped enamel, and between stripping procedures, were observed. Significant differences were found at 0.1 mm of intended stripping (P ≤ 0.05) for the hand-pulled method and at 0.4 mm of intended stripping (P ≤ 0.001 to P = 0.05) for all methods. For all scenarios of enamel reduction, the actual amount of stripping was less than the predetermined and expected amount of stripping. The Kruskal-Wallis analysis showed no significant differences between the 3 methods. CONCLUSIONS There were variations in the stripped amounts of enamel, and the stripping technique did not appear to be a significant predictor of the actual amount of enamel reduction. In most cases, actual stripping was less than the intended amount of enamel reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CASPARIAN STRIP MEMBRANE DOMAIN PROTEINS (CASPs) are four-membrane-span proteins that mediate the deposition of Casparian strips in the endodermis by recruiting the lignin polymerization machinery. CASPs show high stability in their membrane domain, which presents all the hallmarks of a membrane scaffold. Here, we characterized the large family of CASP-like (CASPL) proteins. CASPLs were found in all major divisions of land plants as well as in green algae; homologs outside of the plant kingdom were identified as members of the MARVEL protein family. When ectopically expressed in the endodermis, most CASPLs were able to integrate the CASP membrane domain, which suggests that CASPLs share with CASPs the propensity to form transmembrane scaffolds. Extracellular loops are not necessary for generating the scaffold, since CASP1 was still able to localize correctly when either one of the extracellular loops was deleted. The CASP first extracellular loop was found conserved in euphyllophytes but absent in plants lacking Casparian strips, an observation that may contribute to the study of Casparian strip and root evolution. In Arabidopsis (Arabidopsis thaliana), CASPL showed specific expression in a variety of cell types, such as trichomes, abscission zone cells, peripheral root cap cells, and xylem pole pericycle cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanical ventilation is not only a life saving treatment but can also cause negative side effects. One of the main complications is inflammation caused by overstretching of the alveolar tissue. Previously, studies investigated either global strains or looked into which states lead to inflammatory reactions in cell cultures. However, the connection between the global deformation, of a tissue strip or the whole organ, and the strains reaching the single cells lining the alveolar walls is unknown and respective studies are still missing. The main reason for this is most likely the complex, sponge-like alveolar geometry, whose three-dimensional details have been unknown until recently. Utilizing synchrotron-based X-ray tomographic microscopy, we were able to generate real and detailed three-dimensional alveolar geometries on which we have performed finite-element simulations. This allowed us to determine, for the first time, a three-dimensional strain state within the alveolar wall. Briefly, precision-cut lung slices, prepared from isolated rat lungs, were scanned and segmented to provide a three-dimensional geometry. This was then discretized using newly developed tetrahedral elements. The main conclusions of this study are that the local strain in the alveolar wall can reach a multiple of the value of the global strain, for our simulations up to four times as high and that thin structures obviously cause hotspots that are especially at risk of overstretching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diabetic nephropathy and end-stage renal failure are still a major cause of mortality amongst patients with diabetes mellitus (DM). In this study, we evaluated the Clinitek-Microalbumin (CM) screening test strip for the detection of microalbuminuria (MA) in a random morning spot urine in comparison with the quantitative assessment of albuminuria in the timed overnight urine collection ("gold standard"). One hundred thirty-four children, adolescents, and young adults with insulin-dependent DM Type 1 were studied at 222 outpatient visits. Because of urinary tract infection and/or haematuria, the data of 13 visits were excluded. Finally, 165 timed overnight urine were collected in the remaining 209 visits (79% sample per visit rate). Ten (6.1%) patients presented MA of > or =15 microg/min. In comparison however, 200 spot urine could be screened (96% sample/visit rate) yielding a significant increase in compliance and screening rate (P<.001, McNemar test). Furthermore, at 156 occasions, the gold standard and CM could be directly compared. The sensitivity and the specificity for CM in the spot urine (cut-off > or =30 mg albumin/l) were 0.89 [95% confidence interval (CI) 0.56-0.99] and 0.73 (CI 0.66-0.80), respectively. The positive and negative predictive value were 0.17 (CI 0.08-0.30) and 0.99 (CI 0.95-1.00), respectively. Considering CM albumin-to-creatinine ratio, the results were poorer than with the albumin concentration alone. Using CM instead of quantitative assessment of albuminuria is not cost-effective (35 US dollars versus 60 US dollars/patient/year). In conclusion, to exclude MA, the CM used in the random spot urine is reliable and easy to handle, but positive screening results of > or =30 mg albumin/l must be confirmed by analyses in the timed overnight collected urine. Although the screening compliance is improved, in terms of analysing random morning spot urine for MA, we cannot recommend CM in a paediatric diabetic outpatient setting because the specificity is far too low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A retrospective evaluation was undertaken of eyelid reconstruction with amniotic membrane or oral mucosal membrane transplantation in patients with lower lid cicatricial entropion after orbital surgery. PATIENTS AND METHODS: Seven patients (four women) were treated with a scar tissue dissection and an amniotic membrane or mucosal membrane transplantation between 2003 and 2006 (Five amniotic membrane grafts and two oral mucosal membrane grafts). In selected cases additional procedures like a lateral tarsal strip operation, a tarsal fracture, or the reinsertion of the lower lid retractors were performed. RESULTS: All patients showed a favourable postoperative result with a good anatomic correction of the entropion and a regression of the preoperative disturbances. All the grafts took well. Two patients had to be reoperated twice and one patient three times as a result of a relapse of the cicatricial entropion. However, as well in these patients the anatomical and functional result was favourable at the end. CONCLUSIONS: The difficult scar dissection with the subsequent amniotic membrane or oral mucosal membrane transplantation seems to be an appropriate procedure to reconstruct complicated cicatricial entropion after orbital surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.