14 resultados para Rule of mixtures
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Environmental quality monitoring of water resources is challenged with providing the basis for safeguarding the environment against adverse biological effects of anthropogenic chemical contamination from diffuse and point sources. While current regulatory efforts focus on monitoring and assessing a few legacy chemicals, many more anthropogenic chemicals can be detected simultaneously in our aquatic resources. However, exposure to chemical mixtures does not necessarily translate into adverse biological effects nor clearly shows whether mitigation measures are needed. Thus, the question which mixtures are present and which have associated combined effects becomes central for defining adequate monitoring and assessment strategies. Here we describe the vision of the international, EU-funded project SOLUTIONS, where three routes are explored to link the occurrence of chemical mixtures at specific sites to the assessment of adverse biological combination effects. First of all, multi-residue target and non-target screening techniques covering a broader range of anticipated chemicals co-occurring in the environment are being developed. By improving sensitivity and detection limits for known bioactive compounds of concern, new analytical chemistry data for multiple components can be obtained and used to characterise priority mixtures. This information on chemical occurrence will be used to predict mixture toxicity and to derive combined effect estimates suitable for advancing environmental quality standards. Secondly, bioanalytical tools will be explored to provide aggregate bioactivity measures integrating all components that produce common (adverse) outcomes even for mixtures of varying compositions. The ambition is to provide comprehensive arrays of effect-based tools and trait-based field observations that link multiple chemical exposures to various environmental protection goals more directly and to provide improved in situ observations for impact assessment of mixtures. Thirdly, effect-directed analysis (EDA) will be applied to identify major drivers of mixture toxicity. Refinements of EDA include the use of statistical approaches with monitoring information for guidance of experimental EDA studies. These three approaches will be explored using case studies at the Danube and Rhine river basins as well as rivers of the Iberian Peninsula. The synthesis of findings will be organised to provide guidance for future solution-oriented environmental monitoring and explore more systematic ways to assess mixture exposures and combination effects in future water quality monitoring.
Resumo:
INTRODUCTION To what extent haematocrit levels (Hct) and platelet counts (PLT) influence the measurement of parameters of thromboelastometry when assessed with the ROTEM® device is unclear. We investigated to what extent thromboelastometry measurements depend on Hct and PLT. MATERIALS AND METHODS Whole blood samples were taken for in-vitro preparations of mixtures with three different levels of PLT and a varying Hct. Maximum clot firmness (MCF), clotting time (CT), clot formation time (CFT) and alpha angle (α) for INTEM, EXTEM, FIBTEM and APTEM was recorded. RESULTS Measurements depended substantially on Hct and PLT. MCF readings were systematically lower with increasing Hct (0.2 vs. 0.4: -7.8 (-8.3 to -7.2); p<0.001, 0.2 vs. 0.55: -14.5 (-17.3 to -14.3); p<0.001) but higher with increasing PLT (50 vs. 125×10(9)/l: 8.2 (4.2 to 12.3); p=0.005, 50 vs. 250×10(9)/l: 12.0 (7.2 to 16.8); p=0.002). CT readings were systematically higher with increasing Hct (0.2 vs. 0.4: 9.2 (6.2 to 12.1); p=0.001, 0.2 vs. 0.55: 38.2 (21.5 to 54.9); p=0.003) while increasing PLT had no influence. CFT readings were also systematically higher with increasing Hct (0.2 vs. 0.4: 83.8 (40.2 to 127.6); p=0.006, 0.2 vs. 0.55: 226.2 (110.7 to 341.7); p=0.006) but systematically lower with increasing PLT (50 vs. 125×10(9)/l: -144.0 (-272.3 to -15.6); p=0.036, 50 vs. 250×10(9)/l: -189.2 (-330.4 to -48.0); p=0.02); readings of the alpha angle showed a similar pattern. CONCLUSIONS Our results suggest that readings of thromboelastometry parameters need to be adjusted by Hct and PLT to avoid potential confounding and miss-interpretations in clinical practice.
Resumo:
On the Limits of Greenwich Mean Time, or The Failure of a Modernist Revolution From the introduction of World Standard Time in 1884 to Einstein’s theory of relativity, the nature and regulation of time was a highly contested issue in modernism, with profound political, social and epistemological consequences. Modernist aesthetic sensibilities widely revolted against the increasingly strict rule of the clock, which, as Georg Simmel observed in “The Metropolis and Mental Life,” was established as the necessary basis of a capitalist, urban life. This paper will focus on the contending conceptions of time arising in key modernist texts by authors like Joyce, Woolf and Conrad. I will argue that the uniformity and regularity of time necessary to a rising capitalist society came under attack in a similar way by both modernist literary aesthetics and new scientific discoveries. However, while Einstein’s theory of relativity may have led to a subsequent change of paradigm in scientific thought, it has failed to significantly alter social and popular conceptions of time. Although alternative ways of thinking and living with time are proposed by modernist authors, they remain isolated aesthetic experiments, ineffectual against the regulatory pressure of economic and social structures. In this struggle about the nature of time, so I suggest, science and literature join force against a society that is increasingly governed by economic reason. The fact that they lost this struggle can serve as a striking illustration of an increasing shift of social influence from science and art towards economy.
Resumo:
OBJECTIVES To investigate the frequency of interim analyses, stopping rules, and data safety and monitoring boards (DSMBs) in protocols of randomized controlled trials (RCTs); to examine these features across different reasons for trial discontinuation; and to identify discrepancies in reporting between protocols and publications. STUDY DESIGN AND SETTING We used data from a cohort of RCT protocols approved between 2000 and 2003 by six research ethics committees in Switzerland, Germany, and Canada. RESULTS Of 894 RCT protocols, 289 prespecified interim analyses (32.3%), 153 stopping rules (17.1%), and 257 DSMBs (28.7%). Overall, 249 of 894 RCTs (27.9%) were prematurely discontinued; mostly due to reasons such as poor recruitment, administrative reasons, or unexpected harm. Forty-six of 249 RCTs (18.4%) were discontinued due to early benefit or futility; of those, 37 (80.4%) were stopped outside a formal interim analysis or stopping rule. Of 515 published RCTs, there were discrepancies between protocols and publications for interim analyses (21.1%), stopping rules (14.4%), and DSMBs (19.6%). CONCLUSION Two-thirds of RCT protocols did not consider interim analyses, stopping rules, or DSMBs. Most RCTs discontinued for early benefit or futility were stopped without a prespecified mechanism. When assessing trial manuscripts, journals should require access to the protocol.
Resumo:
STUDY DESIGN: The biomechanics of vertebral bodies augmented with real distributions of cement were investigated using nonlinear finite element (FE) analysis. OBJECTIVES: To compare stiffness, strength, and stress transfer of augmented versus nonaugmented osteoporotic vertebral bodies under compressive loading. Specifically, to examine how cement distribution, volume, and compliance affect these biomechanical variables. SUMMARY OF BACKGROUND DATA: Previous FE studies suggested that vertebroplasty might alter vertebral stress transfer, leading to adjacent vertebral failure. However, no FE study so far accounted for real cement distributions and bone damage accumulation. METHODS: Twelve vertebral bodies scanned with high-resolution pQCT and tested in compression were augmented with various volumes of cements and scanned again. Nonaugmented and augmented pQCT datasets were converted to FE models, with bone properties modeled with an elastic, plastic and damage constitutive law that was previously calibrated for the nonaugmented models. The cement-bone composite was modeled with a rule of mixture. The nonaugmented and augmented FE models were subjected to compression and their stiffness, strength, and stress map calculated for different cement compliances. RESULTS: Cement distribution dominated the stiffening and strengthening effects of augmentation. Models with cement connecting either the superior or inferior endplate (S/I fillings) were only up to 2 times stiffer than the nonaugmented models with minimal strengthening, whereas those with cement connecting both endplates (S + I fillings) were 1 to 8 times stiffer and 1 to 12 times stronger. Stress increases above and below the cement, which was higher for the S + I cases and was significantly reduced by increasing cement compliance. CONCLUSION: The developed FE approach, which accounts for real cement distributions and bone damage accumulation, provides a refined insight into the mechanics of augmented vertebral bodies. In particular, augmentation with compliant cement bridging both endplates would reduce stress transfer while providing sufficient strengthening.