59 resultados para Robotic Arm
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We investigated the feasibility and safety of four-arm robotic lung lobectomy in patients with lung cancer and described the robotic lobectomy technique with mediastinal lymph node dissection.
Resumo:
BACKGROUND: Several clinical studies on chronic stroke conducted with end-effector-based robots showed improvement of the motor function in the affected arm. Compared to end-effector-based robots, exoskeleton robots provide improved guidance of the human limb and are better suited to train task-oriented movements with a large range of motions. OBJECTIVE: To test whether intensive arm training with the arm exoskeleton ARMin I is feasible with chronic-stroke patients and whether it improves motor function in the paretic arm. METHODS: Three single cases with chronic hemiparesis resulting from unilateral stroke (at least 14 months after stroke). A-B design with 2 weeks of multiple baseline measurements (A), 8 weeks of training (B) with repetitive measurements and a follow-up measurement 8 weeks after training. The training included shoulder and elbow movements with the robotic rehabilitation device ARMin I. Two subjects had three 1-hour sessions per week and 1 subject received five 1-hour sessions per week. The main outcome measurement was the upper-limb part of the Fugl-Meyer Assessment (FMA). RESULTS: The ARMin training was well tolerated by the patients, and the FMA showed moderate, but significant improvements for all 3 subjects (p < 0.05). Most improvements were maintained 8 weeks after discharge. CONCLUSIONS: This study indicates that intensive training with an arm exoskeleton is feasible with chronic-stroke patients. Moderate improvements were found in all 3 subjects, thus further clinical investigations are justified.
Resumo:
In the past decade, several arm rehabilitation robots have been developed to assist neurological patients during therapy. Early devices were limited in their number of degrees of freedom and range of motion, whereas newer robots such as the ARMin robot can support the entire arm. Often, these devices are combined with virtual environments to integrate motivating game-like scenarios. Several studies have shown a positive effect of game-playing on therapy outcome by increasing motivation. In addition, we assume that practicing highly functional movements can further enhance therapy outcome by facilitating the transfer of motor abilities acquired in therapy to daily life. Therefore, we present a rehabilitation system that enables the training of activities of daily living (ADL) with the support of an assistive robot. Important ADL tasks have been identified and implemented in a virtual environment. A patient-cooperative control strategy with adaptable freedom in timing and space was developed to assist the patient during the task. The technical feasibility and usability of the system was evaluated with seven healthy subjects and three chronic stroke patients.
Resumo:
We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.
Resumo:
Robotic exoskeletons can be used to study and treat patients with neurological impairments. They can guide and support the human limb over a large range of motion, which requires that the movement trajectory of the exoskeleton coincide with the one of the human arm. This is straightforward to achieve for rather simple joints like the elbow, but very challenging for complex joints like the human shoulder, which is comprised by several bones and can exhibit a movement with multiple rotational and translational degrees of freedom. Thus, several research groups have developed different shoulder actuation mechanism. However, there are no experimental studies that directly compare the comfort of two different shoulder actuation mechanisms. In this study, the comfort and the naturalness of the new shoulder actuation mechanism of the ARMin III exoskeleton are compared to a ball-and-socket-type shoulder actuation. The study was conducted in 20 healthy subjects using questionnaires and 3D-motion records to assess comfort and naturalness. The results indicate that the new shoulder actuation is slightly better than a ball-and-socket-type actuation. However, the differences are small, and under the tested conditions, the comfort and the naturalness of the two tested shoulder actuations do not differ a lot.
Resumo:
BACKGROUND: Arm hemiparesis secondary to stroke is common and disabling. We aimed to assess whether robotic training of an affected arm with ARMin--an exoskeleton robot that allows task-specific training in three dimensions-reduces motor impairment more effectively than does conventional therapy. METHODS: In a prospective, multicentre, parallel-group randomised trial, we enrolled patients who had had motor impairment for more than 6 months and moderate-to-severe arm paresis after a cerebrovascular accident who met our eligibility criteria from four centres in Switzerland. Eligible patients were randomly assigned (1:1) to receive robotic or conventional therapy using a centre-stratified randomisation procedure. For both groups, therapy was given for at least 45 min three times a week for 8 weeks (total 24 sessions). The primary outcome was change in score on the arm (upper extremity) section of the Fugl-Meyer assessment (FMA-UE). Assessors tested patients immediately before therapy, after 4 weeks of therapy, at the end of therapy, and 16 weeks and 34 weeks after start of therapy. Assessors were masked to treatment allocation, but patients, therapists, and data analysts were unmasked. Analyses were by modified intention to treat. This study is registered with ClinicalTrials.gov, number NCT00719433. FINDINGS: Between May 4, 2009, and Sept 3, 2012, 143 individuals were tested for eligibility, of whom 77 were eligible and agreed to participate. 38 patients assigned to robotic therapy and 35 assigned to conventional therapy were included in analyses. Patients assigned to robotic therapy had significantly greater improvements in motor function in the affected arm over the course of the study as measured by FMA-UE than did those assigned to conventional therapy (F=4.1, p=0.041; mean difference in score 0.78 points, 95% CI 0.03-1.53). No serious adverse events related to the study occurred. INTERPRETATION: Neurorehabilitation therapy including task-oriented training with an exoskeleton robot can enhance improvement of motor function in a chronically impaired paretic arm after stroke more effectively than conventional therapy. However, the absolute difference between effects of robotic and conventional therapy in our study was small and of weak significance, which leaves the clinical relevance in question.
Virtobot--a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy
Resumo:
The Virtopsy project, a multi-disciplinary project that involves forensic science, diagnostic imaging, computer science, automation technology, telematics and biomechanics, aims to develop new techniques to improve the outcome of forensic investigations. This paper presents a new approach in the field of minimally invasive virtual autopsy for a versatile robotic system that is able to perform three-dimensional (3D) surface scans as well as post mortem image-guided soft tissue biopsies.
Resumo:
OBJECTIVES: The aim of this study was to compare the long-term outcomes of implants placed in patients treated for periodontitis periodontally compromised patients (PCP) and in periodontally healthy patients (PHP) in relation to adhesion to supportive periodontal therapy (SPT). MATERIAL AND METHODS: One hundred and twelve partially edentulous patients were consecutively enrolled in private specialist practice and divided into three groups according to their initial periodontal condition: PHP, moderate PCP and severe PCP. Perio and implant treatment was carried out as needed. Solid screws (S), hollow screws (HS) and hollow cylinders (HC) were installed to support fixed prostheses, after successful completion of initial periodontal therapy (full-mouth plaque score <25% and full-mouth bleeding score <25%). At the end of treatment, patients were asked to follow an individualized SPT program. At 10 years, clinical measures and radiographic bone changes were recorded by two calibrated operators, blinded to the initial patient classification. RESULTS: Eleven patients were lost to follow-up. During the period of observation, 18 implants were removed because of biological complications. The implant survival rate was 96.6%, 92.8% and 90% for all implants and 98%, 94.2% and 90% for S-implants only, respectively, for PHP, moderate PCP and severe PCP. The mean bone loss was 0.75 (+/- 0.88) mm in PHP, 1.14 (+/- 1.11) mm in moderate PCP and 0.98 (+/- 1.22) mm in severe PCP, without any statistically significant difference. The percentage of sites, with bone loss > or =3 mm, was, respectively, 4.7% for PHP, 11.2% for moderate PCP and 15.1% for severe PCP, with a statistically significant difference between PHP and severe PCP (P<0.05). Lack of adhesion to SPT was correlated with a higher incidence of bone loss and implant loss. CONCLUSION: Patients with a history of periodontitis presented a lower survival rate and a statistically significantly higher number of sites with peri-implant bone loss. Furthermore, PCP, who did not completely adhere to the SPT, were found to present a higher implant failure rate. This underlines the value of the SPT in enhancing the long-term outcomes of implant therapy, particularly in subjects affected by periodontitis, in order to control reinfection and limit biological complications.
Resumo:
Concerns of rising healthcare costs and the ever increasing desire to improve surgical outcome have motivated the development of a new robotic assisted surgical procedure for the implantation of artificial hearing devices (AHDs). This paper describes our efforts to enable minimally invasive, cost effective surgery for the implantation of AHDs. We approach this problem with a fundamental goal to reduce errors from every component of the surgical workflow from imaging and trajectory planning to patient tracking and robot development. These efforts were successful in reducing overall system error to a previously unattained level.
Resumo:
pegylated liposomal doxorubicin (PLD) and bevacizumab are active agents in the treatment of metastatic breast cancer (MBC). We carried out a multicenter, single-arm phase II trial to evaluate the toxicity and efficacy of PLD and bevacizumab as first-line treatment in MBC patients.
Resumo:
We evaluated the concurrent and predictive validity of a novel robotic surgery simulator in a prospective, randomized study.
Resumo:
With the increasing use of laparoscopic and robotic radical cystectomy (RC), there are perceived concerns about the adequacy of lymph node dissection (LND).
Resumo:
To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses.