8 resultados para Ribs

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Though developed for thoracic insufficiency syndrome, the spinal growth-stimulating potential and the ease of placement of vertical expandable titanium ribs (VEPTRs) has resulted in their widespread use for early-onset spine deformity. Observation of implant-related ossifications warrants further assessment, since they may be detrimental to the function-preserving non-fusion strategy. PATIENTS AND METHODS Radiographs (obtained pre and post index procedure, and at 4-year follow-up) and the records of 65 VEPTR patients from four paediatric spine centres were analysed. Ossifications were classified as type I (at anchor points), type II (along the central part) or type III (re-ossification after thoracostomy). RESULTS The average age at the index procedure was 6.5 years (min 1, max 13.7). The most prevalent spine problem was congenital scoliosis (37) with rib fusions (34), followed by neuromuscular and syndromic deformities (13 and 8, respectively). Idiopathic and secondary scoliosis (e.g. after thoracotomy) were less frequent (3 and 4, respectively). Forty-two of the 65 (65 %) patients showed ossifications, half of which were around the anchors. Forty-five percent (15/33) without pre-existing rib fusions developed a type II ossification along the implant. Re-ossifications of thoracostomies were less frequent (5/34, 15 %). The occurrence of ossifications was not associated with patient-specific factors. CONCLUSIONS Implant-related ossifications around VEPTR are common. In contrast to harmless bone formation around anchors, ossifications around the telescopic part and the rod section are troublesome in view of their possible negative impact on chest cage compliance and spinal mobility. This potential side effect needs to be considered during implant selection, particularly in patients with originally normal thoracic and spinal anatomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiodermatitis is a known complication in patients having undergone radiotherapy. It usually appears 2 to 5 years after irradiation. We are reporting on a case of radiodermatitis that occurred within months after coronary dilatation and stenting. It started with painful swelling, followed by a typical appearance on the skin surface. Histological finding confirmed the diagnosis. However, magnetic resonance imaging showed changes in the subcutaneous tissue extending into the ribs. A radical debridement was performed including removal of a partially necrotic 4th rib. The defect was closed with a latissimus dorsi transposition flap. Our findings are compared with the literature reports.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FGFRL1 is a novel member of the fibroblast growth factor receptor (FGFR) family. To investigate its expression during mammalian embryonic development, we have used the mouse system. Expression of Fgfrl1 is very low in mouse embryos of day 6 but steadily increases until birth. As demonstrated by in situ hybridization of 16-day-old embryos, the Fgfrl1 mRNA occurs in cartilaginous structures such as the primordia of bones and the permanent cartilage of the trachea, the ribs and the nose. In addition, some muscle types, including the muscles of the tongue and the diaphragm, express Fgfrl1 at relatively high level. In contrast, the heart and the skeletal muscles of the limbs, as well as many other organs (brain, lung, liver, kidney, gut) express Fgfrl1 only at basal level. It is conceivable that Fgfrl1 interacts with other Fgfrs, which are expressed in cartilage and muscle, to modulate FGF signaling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 19-year-old man speeding recklessly along a highway caused a left-frontal crash with another car. After his vehicle came to a standstill, he climbed out of the wreck and crawled across the tarmac to the other side of the road, where he died several minutes after the accident and before the arrival of an ambulance. Postmortem multislice computed tomography (MSCT) demonstrated fractures of the first, second, and third ribs and scapula on the left, an extrapleural hemorrhage in the apical region of the left thorax, as well as a large amount of blood in the left thoracic cavity. These radiologic findings were indicative of a delayed rupture of a traumatic extrapleural hematoma into the pleural space. A traditional autopsy confirmed the very rare diagnosis of a traumatic extrapleural hemorrhage with a delayed rupture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study investigates by means of a new bone-prosthesis interface motion detector whether conceptual design differences of femoral stems are reflected in their primary stability pattern. DESIGN: An in vitro experiment using a biaxial materials testing machine in combination with three-dimensional motion measurement devices was performed. BACKGROUND: Primary stability of uncemented total hip replacements is considered to be a prerequisite for the quality of bony ongrowth to the femoral stem. Dynamic motion as a response to loading as well as total motion of the prosthesis have to be considered under quasi-physiological cyclic loading conditions. METHODS: Seven paired fresh cadaveric femora were used for the testing of two types of uncemented femoral stems with different anchoring concepts: CLS stem (Spotorno) and Cone Prosthesis (Wagner). Under sinusoidal cyclic loading mimicking in vivo hip joint forces a new measurement technique was applied allowing for the analysis of the three-dimensional interface motion. RESULTS: Considerable differences between the two prostheses could be detected both in their dynamic motion and total motion behaviour. Whereas the CLS stem, due to the wedge-shaped concept, provides smaller total motions, the longitudinal ribs of the Cone prostheses result in a substantially smaller dynamic motion. CONCLUSIONS: The measuring technique provided reliable and accurate data illustrating the three-dimensional interface motion of uncemented femoral stems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The implementation of complementary and alternative therapies into conventional treatment schemes is gaining popularity. However, their use is widely depending on patients’ drive. This case-report focuses on a patient’s experience of the integration of WATSU (WaterShiatsu) in rehabilitative care. Methods: Patient: A 52 year old woman survived a severe motorcycle-accident in which she sustained several fractures on the right side of her body, including ribs, pelvis, and femur. After discharge from stationary care, she independently added WATSU to her rehabilitative regimen. Treatment approach: WATSU is a passive form of hydrotherapy in warm water that aims at relaxation, pain relief, and a sense of secureness. In the reported case, an experienced WATSU-therapist who is also trained in physiotherapy and psychosomatics delivered weekly sessions of one hour duration. Measures used: Qualitative data were collected by patient’s diary. Also the therapist’s notes including The Patient Specific Functional Scale (PSFS) were considered. Results: The patient associated WATSU with trunk mobilization (followed by ameliorated breath), reconciliation with her body, and emotional discharge. She ascribed WATSU lasting effects on her body-image. The therapist employed WATSU for careful mobilization and to equalize awareness throughout the body. The PSFS displayed continuous improvement in all categories except usage of public transportation. Due to complications (elevated inflammation markers) only 6 of 8 scheduled sessions were administered. Conclusions: WATSU was experienced helpful in approaching conditions that are difficult to address by conventional physiotherapy. In early rehabilitation, additional medical/physiotherapeutic skills of contributing complementary therapists are advocated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Distraction-based spinal growth modulation by growing rods or vertical expandable prosthetic titanium ribs (VEPTRs) is the mainstay of instrumented operative strategies to correct early onset spinal deformities. In order to objectify the benefits, it has become common sense to measure the gain in spine height by assessing T1-S1 distance on anteroposterior (AP) radiographs. However, by ignoring growth changes on vertebral levels and by limiting measurement to one plane, valuable data is missed regarding the three-dimensional (3D) effects of growth modulation. This information might be interesting when it comes to final fusion or, even more so, when the protective growing implants are removed and the spine re-exposed to physiologic forces at the end of growth. METHODS The goal of this retrospective radiographic study was to assess the growth modulating impact of year-long, distraction-based VEPTR treatment on the morphology of single vertebral bodies. We digitally measured lumbar vertebral body height (VBH) and upper endplate depth (VBD) at the time of the index procedure and at follow-up in nine patients with rib-to-ileum constructs (G1) spanning an anatomically normal lumbar spine. Nine patients with congenital thoracic scoliosis and VEPTR rib-to-rib constructs, but uninstrumented lumbar spines, served as controls (G2). All had undergone more than eight half-yearly VEPTR expansions. A Wilcoxon signed-rank test was used for statistical comparison of initial and follow-up VBH, VBD and height/depth (H/D) ratio (significance level 0.05). RESULTS The average age was 7.1 years (G1) and 5.2 year (G2, p > 0.05) at initial surgery; the average overall follow-up time was 5.5 years (p = 1). In both groups, VBH increased significantly without a significant intergroup difference. Group 1 did not show significant growth in depth, whereas VBD increased significantly in the control group. As a consequence, the H/D ratio increased significantly in group 1 whereas it remained unchanged in group 2. The growth rate for height in mm/year was 1.4 (group 1) and 1.1 (group 2, p = 0.45), and for depth, it was -0.3 and 1.1 (p < 0.05), respectively. CONCLUSIONS VEPTR growth modulating treatment alters the geometry of vertebral bodies by increasing the H/D ratio. We hypothesize that the implant-related deprivation from axial loads (stress-shielding) impairs anteroposterior growth. The biomechanical consequence of such slender vertebrae when exposed to unprotected loads in case of definitive VEPTR removal at the end of growth is uncertain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION For ultrasonographic diagnosis of a fetal trisomy so-called "soft markers" (=ultrasonographically detectable morphological variants) are used. Detection of a certain number of them increases the diagnostic certainty of a fetal trisomy. Up to now there are very few diagnostically accepted osseous soft markers for trisomy. Hence potential osseous soft markers applicable for first and second trimester ultrasound screening for trisomy 21, 18 or 13 were studied. METHODS Postmortal fetal X-rays (ap, lateral) of 358 fetuses (trisomy 21: n = 109, trisomy 18: n = 46; trisomy 13: n = 38, control group: n = 165). RESULTS Not yet described but with trisomy 21 statistically associated soft markers were un-timely os sternale ossification, delayed os sacrum ossification, shortened os maxillare, reduced os maxillare-jaw-corner distance, augmented orbita height, premature os calcaneus ossification, bell-shaped thorax, coronal clefts, trend to wider binocular as well as wider intraocular distances; for trisomy 18: elevated clavicula slope, reduced number of ribs, bell-shaped thorax, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, shortened os metacarpale IV and V, augmented ratio between biparietal diameter and (osseus and soft-tissue) shoulder width; for trisomy 13: longer os nasale, elevated clavicula slope, premature sternum, delayed os sacrum ossification, delayed/premature cranium ossification, reduced number of ribs, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, augmented orbita height, shortened os metacarpale V and a tendency for a shortened os metacarpale IV. CONCLUSION We found several not yet published osseous soft markers statistically associated with trisomy 21, 18 and 13, which can help to ensure sonographically these aneuploidy diagnoses.