The authors tested an autoclavable external ring retractor, fixed to the operation table, for the endoscopic reconstruction of anterior column injuries of the thoracolumbar junction. It served as a retractor for the diaphragm, and offered a stable support for the scope and other instruments, making an assistant superfluous. Moreover, it allowed bimanual manipulation. Of course, the two-dimensional image, provided by the scope, necessitated proper eye-hand coordination. Twenty-eight consecutive patients underwent either a monosegmental (n = 10) or a bisegmental (n = 18) anterior stabilization in the area Th11L1. Three portals were necessary, but an assistant was not needed. The overall (mean +/- SD) operating time was 196 +/- 56 min, the blood loss was 804 +/- 719 mL. Intraoperatively, one epidural bleeding and a single screw cut-out occurred. All complications were managed endoscopically. Postoperatively, evacuation of a haemothorax (n = 1) was necessary. In all patients, wounds and fractures healed uneventfully. The combination of the endoscopic technique and the retractor system was feasible, successful, safe, and time efficient. Moreover, it allowed for anterior instrumentation of thoracolumbar fractures by a single surgeon. It became the standard approach in the authors' department.
Resumo:
Objective To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Study design Prospective experimental cadaver study. Animals Twenty equine cadavers. Methods Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). Results Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. Conclusion and clinical relevance The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.
Resumo:
BACKGROUND Neuronavigation has become an intrinsic part of preoperative surgical planning and surgical procedures. However, many surgeons have the impression that accuracy decreases during surgery. OBJECTIVE To quantify the decrease of neuronavigation accuracy and identify possible origins, we performed a retrospective quality-control study. METHODS Between April and July 2011, a neuronavigation system was used in conjunction with a specially prepared head holder in 55 consecutive patients. Two different neuronavigation systems were investigated separately. Coregistration was performed with laser-surface matching, paired-point matching using skin fiducials, anatomic landmarks, or bone screws. The initial target registration error (TRE1) was measured using the nasion as the anatomic landmark. Then, after draping and during surgery, the accuracy was checked at predefined procedural landmark steps (Mayfield measurement point and bone measurement point), and deviations were recorded. RESULTS After initial coregistration, the mean (SD) TRE1 was 2.9 (3.3) mm. The TRE1 was significantly dependent on patient positioning, lesion localization, type of neuroimaging, and coregistration method. The following procedures decreased neuronavigation accuracy: attachment of surgical drapes (DTRE2 = 2.7 [1.7] mm), skin retractor attachment (DTRE3 = 1.2 [1.0] mm), craniotomy (DTRE3 = 1.0 [1.4] mm), and Halo ring installation (DTRE3 = 0.5 [0.5] mm). Surgery duration was a significant factor also; the overall DTRE was 1.3 [1.5] mm after 30 minutes and increased to 4.4 [1.8] mm after 5.5 hours of surgery. CONCLUSION After registration, there is an ongoing loss of neuronavigation accuracy. The major factors were draping, attachment of skin retractors, and duration of surgery. Surgeons should be aware of this silent loss of accuracy when using neuronavigation.
Resumo:
OBJECTIVES To assess the influence of the use of Gelpi and Grevel retractors on multifidus muscle blood flow during hemilaminectomy, using a dorsolateral approach, for acute disc extrusion in dogs as measured by laser speckle contrast imaging (LSCI). METHODS Blood flow in the multifidus muscles was measured intra-operatively using LSCI prior to insertion of the retractors, immediately after hemilaminectomy and removal of the retractors, and after 10 minutes of lavage of the surgical site. Plasma creatine kinase levels were measured preoperatively and 12-24 hours postoperatively. RESULTS Muscular blood flow was significantly decreased following retraction and remained lower than initial values 10 minutes after lavage in all dogs. The decrease in blood flow was significantly greater with Gelpi retractors (n = 8) than with Grevel retractors (n = 10). No significant relation was found between the duration of retraction and postoperative changes in creatine kinase levels or blood flow. CLINICAL SIGNIFICANCE Findings in this study demonstrate a drop in blood flow within the multifidus muscles using the dorsolateral approach regardless of retractor type used. Gelpi retractors seem to have greater influence on muscular blood flow than Grevel retractors. Further studies are warranted to confirm this second finding.
Resumo:
AIMS To determine efficacy of a minimally invasive (MI) surgical approach using a human MI lumbar retractor for canine lumbosacral dorsal laminectomy and partial discectomy and to compare this technique to the standard open surgical (OS) approach. METHODS Lumbosacral dorsal laminectomy and partial discectomy was performed on 16 large-breed canine cadavers using either a standard OS (n=8) or MI (n=8) approach. Skin and fascial incision length, procedure time, and intraoperative complications were recorded. Postoperatively specimens were evaluated for laminectomy and discectomy dimensions, and visible damage to the cauda equina and exiting nerve roots. RESULTS Median length of skin and fascial incisions in the OS group were longer than in the MI group (p<0.001). Median laminectomy length was similar between both approaches (p=0.234) but width was greater for the MI than OS approach (p=0.002). Both approaches achieved similar partial discectomy width (p=0.279). Overall surgical time was longer for MI approaches compared to OS, with a median of 18.5 (min 15.5, max 21.8) minutes for MI compared to 14.6 (min 13.1, max 16.9) minutes for OS (p=0.001). CONCLUSIONS The MI approach reduced incision lengths while retaining comparable laminectomy and discectomy dimensions. For this in vitro model the MI approach required more time to complete, but this difference may not be relevant in clinical cases. CLINICAL RELEVANCE Dogs undergoing lumbosacral dorsal laminectomy are commonly large-breed dogs. The traditional open approach requires a large skin incision and soft tissue dissection, especially in overweight animals. A MI approach accomplishing the same surgical result while minimising soft tissue trauma could reduce post-operative pain and recovery time, and may lower wound-related complications. Clinical studies are needed to confirm postoperative benefit and assess operating times in vivo.