24 resultados para Real property, Exchange of

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this prospective observational study were to assess the incidence of intraconal spread during peribulbar (extraconal) anesthesia by real-time ultrasound imaging of the retro-orbital compartment and to determine whether a complete sensory and motor block (with akinesia) of the eye is directly related to the intraconal spread.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 +/- 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 +/- 0.58 vs. 3.65 +/- 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 +/- 7.27 to 19.83 +/- 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: /st> Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. METHODS: /st> In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. RESULTS: /st> The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. CONCLUSIONS: /st> Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To describe the implementation and use of an electronic patient-referral system as an aid to the efficient referral of patients to a remote and specialized treatment center. METHODS AND MATERIALS: A system for the exchange of radiotherapy data between different commercial planning systems and a specially developed planning system for proton therapy has been developed through the use of the PAPYRUS diagnostic image standard as an intermediate format. To ensure the cooperation of the different TPS manufacturers, the number of data sets defined for transfer has been restricted to the three core data sets of CT, VOIs, and three-dimensional dose distributions. As a complement to the exchange of data, network-wide application-sharing (video-conferencing) technologies have been adopted to provide methods for the interactive discussion and assessment of treatments plans with one or more partner clinics. RESULTS: Through the use of evaluation plans based on the exchanged data, referring clinics can accurately assess the advantages offered by proton therapy on a patient-by-patient basis, while the practicality or otherwise of the proposed treatments can simultaneously be assessed by the proton therapy center. Such a system, along with the interactive capabilities provided by video-conferencing methods, has been found to be an efficient solution to the problem of patient assessment and selection at a specialized treatment center, and is a necessary first step toward the full electronic integration of such centers with their remotely situated referral centers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tissue grafts are implanted in orthopedic surgery every day. In order to minimize infection risk, bone allografts are often delipidated with supercritical CO2 and sterilized prior to implantation. This treatment may, however, impair the mechanical behavior of the bone graft tissue. The goal of this study was to determine clinically relevant mechanical properties of treated/sterilized human trabecular bone grafts, e.g. the apparent modulus, strength, and the ability to absorb energy during compaction. They were compared with results of identical experiments performed previously on untreated/fresh frozen human trabecular bone from the same anatomical site (Charlebois, 2008). We tested the hypothesis that the morphology–mechanical property relationships of treated cancellous allografts are similar to those of fresh untreated bone. The morphology of the allografts was determined by μCT. Subsequently, cylindrical samples were tested in unconfined and confined compression. To account for various morphologies, the experimental data was fitted to phenomenological mechanical models for elasticity, strength, and dissipated energy density based on bone volume fraction (BV/TV) and the fabric tensor determined by MIL. The treatment/sterilization process does not appear to influence bone graft stiffness. However, strength and energy dissipation of the bone grafts were found to be significantly reduced by 36% to 47% and 66% to 81%, respectively, for a broad range of volume fraction (0.14 < BV/TV < 0.39) and degree of anisotropy (1.24 < DA < 2.18). Since the latter properties are strongly dominated by BV/TV, the clinical consequences of this reduction can be compensated by using grafts with lower porosity. The data of this study suggests that an increase of 5–10% in BV/TV is sufficient to compensate for the reduced post-yield mechanical properties of treated/sterilized bone in monotonic compression. In applications where graft stiffness needs to be matched and strength is not a concern, treated allograft with the same BV/TV as an appropriate fresh bone graft may be used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT The Swiss Federal Office of Public Health mandated a nationwide health technology assessment-registry for balloon kyphoplasty (BKP) for decision making on reimbursement of these interventions. The early results of the registry led to a permanent coverage of BKP by basic health insurance. The documentation was continued for further evidence generation. PURPOSE This analysis reports on the 1 year results of patients after BKP treatment. STUDY DESIGN Prospective multicenter observational case series. PATIENT SAMPLE The data on 625 cases with 819 treated vertebrae were documented from March 2005 to May 2012. OUTCOME MEASURES Surgeon-administered outcome instruments were primary intervention form for BKP and the follow-up form; patient self-reported measures were EuroQol-5D questionnaire, North American Spine Society outcome instrument /Core Outcome Measures Index (including visual analog scale), and a comorbidity questionnaire. Outcome measures were back pain, medication, quality of life (QoL), cement extrusions, and new fractures within the first postoperative year. METHODS Data were recorded preoperatively and at 3 to 6-month and 1-year follow-ups. Wilcoxon signed-rank test was used for comparison of pre- with postoperative measurements. Multivariate logistic regression was used to identify factors with a significant influence on the outcome. RESULTS Seventy percent of patients were women with mean age of 71 years (range, 18-91 years); mean age of men was 65 years (range, 15-93 years). Significant and clinically relevant reduction of back pain, improvement of QoL, and reduction of pain killer consumption was seen within the first postoperative year. Preoperative back pain decreased from 69.3 to 29.0 at 3 to 6-month and remained unchanged at 1-year follow-ups. Consequently, QoL improved from 0.23 to 0.71 and 0.75 at the same follow-up intervals. The overall vertebra-based cement extrusion rates with and without extrusions into intervertebral discs were 22.1% and 15.3%, respectively. Symptomatic cement extrusions with radiculopathy were five (0.8%). A new vertebral fracture within a year from the BKP surgery was observed in 18.4% of the patients. CONCLUSIONS The results of the largest observational study for BKP so far are consistent with published randomized trials and systematic reviews. In this routine health care setting, BKP is safe and effective in reducing pain, improving QoL, and lowering pain_killer consumption and has an acceptable rate of cement extrusions. Postoperative outcome results show clear and significant clinical improvement at early follow-up that remain stable during the first postoperative year.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intermolecular electron-transfer reactions have a crucial role in biology, solution chemistry and electrochemistry. The first step of such reactions is the expulsion of the electron to the solvent, whose mechanism is determined by the structure and dynamical response of the latter. Here we visualize the electron transfer to water using ultrafast fluorescence spectroscopy with polychromatic detection from the ultraviolet to the visible region, upon photo-excitation of the so-called charge transfer to solvent states of aqueous iodide. The initial emission is short lived (~60 fs) and it relaxes to a broad distribution of lower-energy charge transfer to solvent states upon rearrangement of the solvent cage. This distribution reflects the inhomogeneous character of the solvent cage around iodide. Electron ejection occurs from the relaxed charge transfer to solvent states with lifetimes of 100–400 fs that increase with decreasing emission energy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy is of primary concern in wireless sensor networks (WSNs). Low power transmission makes the wireless links unreliable, which leads to frequent topology changes. Resulting packet retransmissions aggravate the energy consumption. Beaconless routing approaches, such as opportunistic routing (OR) choose packet forwarders after data transmissions, and are promising to support dynamic features of WSNs. This paper proposes SCAD - Sensor Context-aware Adaptive Duty-cycled beaconless OR for WSNs. SCAD is a cross-layer routing solution and it brings the concept of beaconless OR into WSNs. SCAD selects packet forwarders based on multiple types of network contexts. To achieve a balance between performance and energy efficiency, SCAD adapts duty-cycles of sensors based on real-time traffic loads and energy drain rates. We implemented SCAD in TinyOS running on top of Tmote Sky sensor motes. Real-world evaluations show that SCAD outperforms other protocols in terms of both throughput and network lifetime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider a large quantum system with spins 12 whose dynamics is driven entirely by measurements of the total spin of spin pairs. This gives rise to a dissipative coupling to the environment. When one averages over the measurement results, the corresponding real-time path integral does not suffer from a sign problem. Using an efficient cluster algorithm, we study the real-time evolution from an initial antiferromagnetic state of the two-dimensional Heisenberg model, which is driven to a disordered phase, not by a Hamiltonian, but by sporadic measurements or by continuous Lindblad evolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the real-time evolution of large open quantum spin systems in two spatial dimensions, whose dynamics is entirely driven by a dissipative coupling to the environment. We consider different dissipative processes and investigate the real-time evolution from an ordered phase of the Heisenberg or XY model towards a disordered phase at late times, disregarding unitary Hamiltonian dynamics. The corresponding Kossakowski-Lindblad equation is solved via an efficient cluster algorithm. We find that the symmetry of the dissipative process determines the time scales, which govern the approach towards a new equilibrium phase at late times. Most notably, we find a slow equilibration if the dissipative process conserves any of the magnetization Fourier modes. In these cases, the dynamics can be interpreted as a diffusion process of the conserved quantity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Selective retina therapy (SRT) is a novel treatment for retinal pathologies, solely targeting the retinal pigment epithelium (RPE). During SRT, the detection of an immediate tissue reaction is challenging as tissue effects remain limited to intracellular RPE photodisruption. Time-resolved ultra-high axial resolution optical coherence tomography (OCT) is thus evaluated for the monitoring of dynamic optical changes at and around the RPE during SRT. Methods: An experimental OCT system with an ultra-high axial resolution of 1.78 µm was combined with an SRT system and time-resolved OCT M-scans of the target area were recorded from four patients undergoing SRT. OCT scans were analyzed and OCT morphology was correlated with findings in fluorescein angiography, fundus photography and cross-sectional OCT. Results: In cases where the irradiation caused RPE damage proven by fluorescein angiography, the lesions were well discernible in time-resolved OCT images but remained invisible in fundus photography and cross-sectional OCT acquired after treatment. If RPE damage was introduced, all applied SRT pulses led to detectable signal changes in the time-resolved OCT images. The extent of optical signal variation seen in the OCT data appeared to scale with the applied SRT pulse energy. Conclusion: The first clinical results proved that successful SRT irradiation induces detectable changes in the OCT M-scan signal while it remains invisible in conventional ophthalmoscopic imaging. Thus, real-time high-resolution OCT is a promising modality to monitor and analyze tissue effects introduced by selective retina therapy and may be used to guide SRT in an automatic feedback mode.