3 resultados para Reagent Strips

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific gravity of urine (SG) indicates the number and weight of solute particles in urine; its measurement is helpful in interpreting proteinuria detected by dipstick tests and in monitoring adequate hydration in patients with nephrolithiasis. Four methods for measuring SG or osmolality of urine are currently available (depression of the freezing-point, urometry, refractometry, cation exchange on a reagent strip). Using a recently developed reagent strip, we have measured SG in morning urines of 340 non-selected outpatients and compared the results with SG measurements by refractometry of the same urines. In 86.2% of all urines, a good positive correlation between SG measured by reagent strip and refractometry was noted (r = 0.913, p = 0.0001). In 13.8% of the urines, however, the SG measured by reagent strip deviated by more than +/- 5 from the value obtained by refractometry; in 90% of these urines, glucosuria (reagent strip values too low or too high), proteinuria (values too high), or bacteriuria/leukocyturia (values too low or too high) could be found. In alkaline urine (pH > 7.0), SG values obtained by reagent strip have to be corrected by +5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A broad spectrum of synthetic agents is available for the treatment of overactive bladder. Anti-cholinergic drugs show a poor compliance due to side effects. There is an increasing use of plant extracts in medicine. We have therefore investigated the inhibitory effects of leaf press juice from Bryophyllum pinnatum (Lam.) Oken (Kalanchoe pinnata L.) on bladder strips and compared the effects to that of oxybutynin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.