26 resultados para Reading Time Workshop
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Hemianopic reading impairment is a consequence of a visual field defect to either the right or the left side and is characterized by an increased reading time and reduced reading performance. Depending on the side of the visual field defect, reading will be affected differently: Patients suffering from a visual field defect to the right side have noticeable difficulties in reading fluently with slowing. Patients suffering from a visual field defect to the left usually struggle to find the beginning of a line and read more fluently. It was suggested in the literature that changing the reading direction from horizontal to vertical may be a training strategy to reduce reading problems in patients with hemianopia. The aim of the study was to investigate the influence of reading direction on reading speed in patients with left- or right-sided visual field defects and in healthy controls. METHOD In 13 patients with hemianopia and in 13 age-matched controls, reading speed was calculated for texts in standard as well as in clockwise rotated orientation of 90, 180, and 270°. RESULTS In both groups, text rotation reduced reading speed compared to standard reading. Patients with left-sided hemianopia had the greatest reduction after text rotation. Patients with right-sided hemianopia had the smallest speed reduction in 90° vertically rotated texts. CONCLUSIONS Text rotation has different effects in left- or right-sided hemianopia patients. For patients with left-sided heminanopia, rotation of the text may not be a helpful training strategy, for right-sided hemianopia vertical rotation of the text of 90° may be a beneficial training strategy to reduce reading deficits.
Resumo:
A word-length effect is often described in pure alexia, with reading time proportional to the number of letters in a word. Given the frequent association of right hemianopia with pure alexia, it is uncertain whether and how much of the word-length effect may be attributable to the hemifield loss. To isolate the contribution of the visual field defect, we simulated hemianopia in healthy subjects with a gaze-contingent paradigm during an eye-tracking experiment. We found a minimal word-length effect of 14 ms/letter for full-field viewing, which increased to 38 ms/letter in right hemianopia and to 31 ms/letter in left hemianopia. We found a correlation between mean reading time and the slope of the word-length effect in hemianopic conditions. The 95% upper prediction limits for the word-length effect were 51 ms/letter in subjects with full visual fields and 161 ms/letter with simulated right hemianopia. These limits, which can be considered diagnostic criteria for an alexic word-length effect, were consistent with the reading performance of six patients with diagnoses based independently on perimetric and imaging data: two patients with probable hemianopic dyslexia, and four with alexia and lesions of the left fusiform gyrus, two with and two without hemianopia. Two of these patients also showed reduction of the word-length effect over months, one with and one without a reading rehabilitation program. Our findings clarify the magnitude of the word-length effect that originates from hemianopia alone, and show that the criteria for a word-length effect indicative of alexia differ according to the degree of associated hemifield loss.
Resumo:
Pure alexia is an acquired reading disorder characterized by a disproportionate prolongation of reading time as a function of word length. Although the vast majority of cases reported in the literature show a right-sided visual defect, little is known about the contribution of this low-level visual impairment to their reading difficulties. The present study was aimed at investigating this issue by comparing eye movement patterns during text reading in six patients with pure alexia with those of six patients with hemianopic dyslexia showing similar right-sided visual field defects. We found that the role of the field defect in the reading difficulties of pure alexics was highly deficit-specific. While the amplitude of rightward saccades during text reading seems largely determined by the restricted visual field, other visuo-motor impairments-particularly the pronounced increases in fixation frequency and viewing time as a function of word length-may have little to do with their visual field defect. In addition, subtracting the lesions of the hemianopic dyslexics from those found in pure alexics revealed the largest group differences in posterior parts of the left fusiform gyrus, occipito-temporal sulcus and inferior temporal gyrus. These regions included the coordinate assigned to the centre of the visual word form area in healthy adults, which provides further evidence for a relation between pure alexia and a damaged visual word form area. Finally, we propose a list of three criteria that may improve the differential diagnosis of pure alexia and allow appropriate therapy recommendations.
Resumo:
Background Conventional cross-sectional imaging with computed tomography and magnetic resonance imaging (MRI) has limited accuracy for lymph node (LN) staging in bladder and prostate cancer patients. Objective To prospectively assess the diagnostic accuracy of combined ultrasmall superparamagnetic particles of iron oxide (USPIO) MRI and diffusion-weighted (DW) MRI in staging of normal-sized pelvic LNs in bladder and/or prostate cancer patients. Design, setting, and participants Examinations with 3-Tesla MRI 24–36 h after administration of USPIO using conventional MRI sequences combined with DW-MRI (USPIO-DW-MRI) were performed in 75 patients with clinically localised bladder and/or prostate cancer staged previously as N0 by conventional cross-sectional imaging. Combined USPIO-DW-MRI findings were analysed by three independent readers and correlated with histopathologic LN findings after extended pelvic LN dissection (PLND) and resection of primary tumours. Outcome measurements and statistical analysis Sensitivity and specificity for LN status of combined USPIO-DW-MRI versus histopathologic findings were evaluated per patient (primary end point) and per pelvic side (secondary end point). Time required for combined USPIO-DW-MRI reading was assessed. Results and limitations At histopathologic analysis, 2993 LNs (median: 39 LNs; range: 17–68 LNs per patient) with 54 LN metastases (1.8%) were found in 20 of 75 (27%) patients. Per-patient sensitivity and specificity for detection of LN metastases by the three readers ranged from 65% to 75% and 93% to 96%, respectively; sensitivity and specificity per pelvic side ranged from 58% to 67% and 94% to 97%, respectively. Median reading time for the combined USPIO-DW-MRI images was 9 min (range: 3–26 min). A potential limitation is the absence of a node-to-node correlation of combined USPIO-DW-MRI and histopathologic analysis. Conclusions Combined USPIO-DW-MRI improves detection of metastases in normal-sized pelvic LNs of bladder and/or prostate cancer patients in a short reading time.
Resumo:
PURPOSE We prospectively assessed the diagnostic accuracy of diffusion-weighted magnetic resonance imaging for detecting significant prostate cancer. MATERIALS AND METHODS We performed a prospective study of 111 consecutive men with prostate and/or bladder cancer who underwent 3 Tesla diffusion-weighted magnetic resonance imaging of the pelvis without an endorectal coil before radical prostatectomy (78) or cystoprostatectomy (33). Three independent readers blinded to clinical and pathological data assigned a prostate cancer suspicion grade based on qualitative imaging analysis. Final pathology results of prostates with and without cancer served as the reference standard. Primary outcomes were the sensitivity and specificity of diffusion-weighted magnetic resonance imaging for detecting significant prostate cancer with significance defined as a largest diameter of the index lesion of 1 cm or greater, extraprostatic extension, or Gleason score 7 or greater on final pathology assessment. Secondary outcomes were interreader agreement assessed by the Fleiss κ coefficient and image reading time. RESULTS Of the 111 patients 93 had prostate cancer, which was significant in 80 and insignificant in 13, and 18 had no prostate cancer on final pathology results. The sensitivity and specificity of diffusion-weighted magnetic resonance imaging for detecting significant PCa was 89% to 91% and 77% to 81%, respectively, for the 3 readers. Interreader agreement was good (Fleiss κ 0.65 to 0.74). Median reading time was between 13 and 18 minutes. CONCLUSIONS Diffusion-weighted magnetic resonance imaging (3 Tesla) is a noninvasive technique that allows for the detection of significant prostate cancer with high probability without contrast medium or an endorectal coil, and with good interreader agreement and a short reading time. This technique should be further evaluated as a tool to stratify patients with prostate cancer for individualized treatment options.
Resumo:
Software must be constantly adapted due to evolving domain knowledge and unanticipated requirements changes. To adapt a system at run-time we need to reflect on its structure and its behavior. Object-oriented languages introduced reflection to deal with this issue, however, no reflective approach up to now has tried to provide a unified solution to both structural and behavioral reflection. This paper describes Albedo, a unified approach to structural and behavioral reflection. Albedo is a model of fined-grained unanticipated dynamic structural and behavioral adaptation. Instead of providing reflective capabilities as an external mechanism we integrate them deeply in the environment. We show how explicit meta-objects allow us to provide a range of reflective features and thereby evolve both application models and environments at run-time.
Resumo:
Diagnostics imaging is an essential component of patient selection and treatment planning in oral rehabilitation by means of osseointegrated implants. In 2002, the EAO produced and published guidelines on the use of diagnostic imaging in implant dentistry. Since that time, there have been significant developments in both the application of cone beam computed tomography as well as in the range of surgical and prosthetic applications that can potentially benefit from its use. However, medical exposure to ionizing radiation must always be justified and result in a net benefit to the patient. The as low a dose as is reasonably achievable principle must also be applied taking into account any alternative techniques that might achieve the same objectives. This paper reports on current EAO recommendations arising from a consensus meeting held at the Medical University of Warsaw (2011) to update these guidelines. Radiological considerations are detailed, including justification and optimization, with a special emphasis on the obligations that arise for those who prescribe or undertake such investigations. The paper pays special attention to clinical indications and radiographic diagnostic considerations as well as to future developments and trends.
Resumo:
When sight-reading a piece of music the eyes constantly scan the score slightly ahead of music execution. This separation between reading and acting is commonly termed eye-hand span and can be expressed in two ways: as anticipation in notes or in time. Previous research, predominantly in piano players, found skill-dependent differences of eye-hand span. To date no study has explored visual anticipation in violinists. The present study investigated how structural properties of a piece of music affect the eye-hand span in a group of violinists. To this end eye movements and bow reversals were recorded synchronously while musicians sight-read a piece of music. The results suggest that structural differences of the score are reflected in the eye-hand span in a way similar to skill level. Specifically, the piece with higher complexity was associated with lower anticipation in notes, longer fixation duration and a tendency for more regressive fixations. Anticipation in time, however, remained the same (approximately 1 s) independently of the score played but was correlated with playing tempo. We conclude that the eye-hand span is not only influenced by the experience of the musician, but also by the structure of the score to be played.