16 resultados para Ratio Test Integer Aperture (RTIA)

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reliable quantification of gene copy number variations is a precondition for future investigations regarding their functional relevance. To date, there is no generally accepted gold standard method for copy number quantification, and methods in current use have given inconsistent results in selected cohorts. In this study, we compare two methods for copy number quantification. beta-defensin gene copy numbers were determined in parallel in 80 genomic DNA samples by real-time PCR and multiplex ligation-dependent probe amplification (MLPA). The pyrosequencing-based paralog ratio test (PPRT) was used as a standard of comparison in 79 out of 80 samples. Realtime PCR and MPLA results confirmed concordant DEFB4, DEFB103A, and DEFB104A copy numbers within samples. These two methods showed identical results in 32 out of 80 samples; 29 of these 32 samples comprised four or fewer copies. The coefficient of variation of MLPA is lower compared with PCR. In addition, the consistency between MLPA and PPRT is higher than either PCR/MLPA or PCR/PPRT consistency. In summary, these results suggest that MLPA is superior to real-time PCR in beta-defensin copy number quantification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phylogenies of housekeeping gene and 16S rRNA gene sequences were compared to improve the classification of the bacterial family Pasteurellaceae and knowledge of the evolutionary relationships of its members. Deduced partial protein sequences of the housekeeping genes atpD, infB and rpoB were compared in 28, 36 and 28 representative taxa of the Pasteurellaceae, respectively. The monophyly of representatives of the genus Gallibacterium was recognized by analysis of all housekeeping genes, while members of Mannheimia, Actinobacillus sensu stricto and the core group of Pasteurella sensu stricto formed monophyletic groups with two out of three housekeeping genes. Representatives of Mannheimia, Actinobacillus sensu stricto, [Haemophilus] ducreyi and [Pasteurella] trehalosi formed a monophyletic unit by analysis of all three housekeeping genes, which was in contrast to the 16S rRNA gene-derived phylogeny, where these taxa occurred at separate positions in the phylogenetic tree. Representatives of the Rodent, Avian and Aphrophilus-Haemophilus 16S rRNA gene groups were weakly supported by phylogenetic analysis of housekeeping genes. Phylogenies derived by comparison of the housekeeping genes diverged significantly from the 16S rRNA gene-derived phylogeny as evaluated by the likelihood ratio test. A low degree of congruence was also observed between the individual housekeeping gene-derived phylogenies. Estimates on speciation derived from 16S rRNA and housekeeping gene sequence comparisons resulted in quite different evolutionary scenarios for members of the Pasteurellaceae. The phylogeny based on the housekeeping genes supported observed host associations between Mannheimia, Actinobacillus sensu stricto and [Pasteurella] trehalosi and animals with paired hooves.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lung function measures are heritable, predict mortality and are relevant in diagnosis of chronic obstructive pulmonary disease (COPD). COPD and asthma are diseases of the airways with major public health impacts and each have a heritable component. Genome-wide association studies of SNPs have revealed novel genetic associations with both diseases but only account for a small proportion of the heritability. Complex copy number variation may account for some of the missing heritability. A well-characterised genomic region of complex copy number variation contains beta-defensin genes (DEFB103, DEFB104 and DEFB4), which have a role in the innate immune response. Previous studies have implicated these and related genes as being associated with asthma or COPD. We hypothesised that copy number variation of these genes may play a role in lung function in the general population and in COPD and asthma risk. We undertook copy number typing of this locus in 1149 adult and 689 children using a paralogue ratio test and investigated association with COPD, asthma and lung function. Replication of findings was assessed in a larger independent sample of COPD cases and smoking controls. We found evidence for an association of beta-defensin copy number with COPD in the adult cohort (OR = 1.4, 95%CI:1.02-1.92, P = 0.039) but this finding, and findings from a previous study, were not replicated in a larger follow-up sample(OR = 0.89, 95%CI:0.72-1.07, P = 0.217). No robust evidence of association with asthma in children was observed. We found no evidence for association between beta-defensin copy number and lung function in the general populations. Our findings suggest that previous reports of association of beta-defensin copy number with COPD should be viewed with caution. Suboptimal measurement of copy number can lead to spurious associations. Further beta-defensin copy number measurement in larger sample sizes of COPD cases and children with asthma are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cichlid fish inhabit a diverse range of environments that vary in the spectral content of light available for vision. These differences should result in adaptive selective pressure on the genes involved in visual sensitivity, the opsin genes. This study examines the evidence for differential adaptive molecular evolution in East African cichlid opsin genes due to gross differences in environmental light conditions. First, we characterize the selective regime experienced by cichlid opsin genes using a likelihood ratio test format, comparing likelihood models with different constraints on the relative rates of amino acid substitution, across sites. Second, we compare turbid and clear lineages to determine if there is evidence of differences in relative rates of substitution. Third, we present evidence of functional diversification and its relationship to the photic environment among cichlid opsin genes. We report statistical evidence of positive selection in all cichlid opsin genes, except short wavelength–sensitive 1 and short wavelength–sensitive 2b. In all genes predicted to be under positive selection, except short wavelength–sensitive 2a, we find differences in selective pressure between turbid and clear lineages. Potential spectral tuning sites are variable among all cichlid opsin genes; however, patterns of substitution consistent with photic environment–driven evolution of opsin genes are observed only for short wavelength–sensitive 1 opsin genes. This study identifies a number of promising candidate-tuning sites for future study by site-directed mutagenesis. This work also begins to demonstrate the molecular evolutionary dynamics of cichlid visual sensitivity and its relationship to the photic environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Sepsis continues to be a major cause of death, disability, and health-care expenditure worldwide. Despite evidence suggesting that host genetics can influence sepsis outcomes, no specific loci have yet been convincingly replicated. The aim of this study was to identify genetic variants that influence sepsis survival. METHODS We did a genome-wide association study in three independent cohorts of white adult patients admitted to intensive care units with sepsis, severe sepsis, or septic shock (as defined by the International Consensus Criteria) due to pneumonia or intra-abdominal infection (cohorts 1-3, n=2534 patients). The primary outcome was 28 day survival. Results for the cohort of patients with sepsis due to pneumonia were combined in a meta-analysis of 1553 patients from all three cohorts, of whom 359 died within 28 days of admission to the intensive-care unit. The most significantly associated single nucleotide polymorphisms (SNPs) were genotyped in a further 538 white patients with sepsis due to pneumonia (cohort 4), of whom 106 died. FINDINGS In the genome-wide meta-analysis of three independent pneumonia cohorts (cohorts 1-3), common variants in the FER gene were strongly associated with survival (p=9·7 × 10(-8)). Further genotyping of the top associated SNP (rs4957796) in the additional cohort (cohort 4) resulted in a combined p value of 5·6 × 10(-8) (odds ratio 0·56, 95% CI 0·45-0·69). In a time-to-event analysis, each allele reduced the mortality over 28 days by 44% (hazard ratio for death 0·56, 95% CI 0·45-0·69; likelihood ratio test p=3·4 × 10(-9), after adjustment for age and stratification by cohort). Mortality was 9·5% in patients carrying the CC genotype, 15·2% in those carrying the TC genotype, and 25·3% in those carrying the TT genotype. No significant genetic associations were identified when patients with sepsis due to pneumonia and intra-abdominal infection were combined. INTERPRETATION We have identified common variants in the FER gene that associate with a reduced risk of death from sepsis due to pneumonia. The FER gene and associated molecular pathways are potential novel targets for therapy or prevention and candidates for the development of biomarkers for risk stratification. FUNDING European Commission and the Wellcome Trust.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Chronic haemodialysis patients are a high-risk population for meticillin-resistant Staphylococcus aureus (MRSA) colonization, which is a precursor of infection. AIM To summarize the effect of nasal (± whole-body wash) MRSA decolonization in haemodialysis patients by means of a systematic review and meta-analysis. METHODS We identified eligible studies using Medline, Embase, the Cochrane database, clinicaltrials.org, and conference abstracts investigating the success of MRSA decolonization in haemodialysis patients. For the statistical analysis, we used Stata 13 to express study-specific proportions with 95% confidence intervals. A likelihood ratio test was used to assess inter-study heterogeneity. FINDINGS Six published prospective cohort studies and one study described in a conference abstract met our inclusion criteria. From 1150 haemodialysis patients enrolled in these studies, MRSA was isolated from nasal swabs of 147 (12.8%) patients. Six of the trials used mupirocin nasal ointment and combined it with chlorhexidine body washes for decolonization. The most widely used protocol was a five-day course of mupirocin nasal ointment application three times a day, and chlorhexidine body wash once daily. The pooled success rate of decolonization was 0.88 (95% confidence interval: 0.75-0.95). A likelihood ratio test of the fixed versus the random-effects model showed significant inter-study heterogeneity (P = 0.047). Four of seven studies determined subsequent MRSA infections in 94 carriers overall, two (2%) of which experienced infection. CONCLUSION The use of mupirocin together with whole-body decolonization is highly effective in eradicating MRSA carriage in haemodialysis patients. The current literature, however, is characterized by a lack of comparative effectiveness studies for this intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Congestive heart failure (CHF) is a major public health problem. The use of B-type natriuretic peptide (BNP) tests shows promising diagnostic accuracy. Herein, we summarize the evidence on the accuracy of BNP tests in the diagnosis of CHF and compare the performance of rapid enzyme-linked immunosorbent assay (ELISA) and standard radioimmunosorbent assay (RIA) tests. METHODS: We searched electronic databases and the reference lists of included studies, and we contacted experts. Data were extracted on the study population, the type of test used, and methods. Receiver operating characteristic (ROC) plots and summary ROC curves were produced and negative likelihood ratios pooled. Random-effect meta-analysis and metaregression were used to combine data and explore sources of between-study heterogeneity. RESULTS: Nineteen studies describing 22 patient populations (9 ELISA and 13 RIA) and 9093 patients were included. The diagnosis of CHF was verified by echocardiography, radionuclide scan, or echocardiography combined with clinical criteria. The pooled negative likelihood ratio overall from random-effect meta-analysis was 0.18 (95% confidence interval [CI], 0.13-0.23). It was lower for the ELISA test (0.12; 95% CI, 0.09-0.16) than for the RIA test (0.23; 95% CI, 0.16-0.32). For a pretest probability of 20%, which is typical for patients with suspected CHF in primary care, a negative result of the ELISA test would produce a posttest probability of 2.9%; a negative RIA test, a posttest probability of 5.4%. CONCLUSIONS: The use of BNP tests to rule out CHF in primary care settings could reduce demand for echocardiography. The advantages of rapid ELISA tests need to be balanced against their higher cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To test a system with milk flow-controlled pulsation, milk flow was recorded in 29 Holstein cows during machine milking. The three different treatments were routine milking (including a pre-stimulation of 50-70 s), milking with a minimum of teat preparation and milking with milk flow-controlled b-phase, i.e. with a gradually elongated b-phase of the pulsation cycle with increasing milk flow rate and shortening again during decreasing milk flow. For data evaluation the herd was divided into three groups based on the peak flow rate at routine milking (group 1: <3.2 kg/min; group 2: 3.2-4.5 kg/min; group 3: >4.5 kg/min). Compared with routine milking, milking with milk flow-controlled b-phase caused a significant elevation of the peak flow rate and the duration of incline lasted longer especially in cows with a peak flow rate of >3.2 kg/min in routine milking. In milking with a minimum of teat preparation the duration of incline lasted longer compared with the two other treatments. Bimodality of milk flow, i.e. delayed milk ejection at the start of milking, was most frequent at milking with a minimum of teat preparation. No significant differences between routine milking and milking with milk flow-controlled b-phase were detected for all other milking characteristics. In summary, milking with milk flow-controlled b-phase changes the course of milk removal, however mainly in cows with high peak flow rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The value of cerebrospinal fluid (CSF) lactate level and CSF/blood glucose ratio for the identification of bacterial meningitis following neurosurgery was assessed in a retrospective study. During a 3-year period, 73 patients fulfilled the inclusion criteria and could be grouped by preset criteria in one of three categories: proven bacterial meningitis (n = 12), presumed bacterial meningitis (n = 14), and nonbacterial meningeal syndrome (n = 47). Of 73 patients analyzed, 45% were treated with antibiotics and 33% with steroids at the time of first lumbar puncture. CSF lactate values (cutoff, 4 mmol/L), in comparison with CSF/blood glucose ratios (cutoff, 0.4), were associated with higher sensitivity (0.88 vs. 0.77), specificity (0.98 vs. 0.87), and positive (0.96 vs. 0.77) and negative (0.94 vs. 0.87) predictive values. In conclusion, determination of the CSF lactate value is a quick, sensitive, and specific test to identify patients with bacterial meningitis after neurosurgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND AIMS We investigated the association between significant liver fibrosis, determined by AST-to-platelet ratio index (APRI), and all-cause mortality among HIV-infected patients prescribed antiretroviral therapy (ART) in Zambia METHODS: Among HIV-infected adults who initiated ART, we categorized baseline APRI scores according to established thresholds for significant hepatic fibrosis (APRI ≥1.5) and cirrhosis (APRI ≥2.0). Using multivariable logistic regression we identified risk factors for elevated APRI including demographic characteristics, body mass index (BMI), HIV clinical and immunologic status, and tuberculosis. In the subset tested for hepatitis B surface antigen (HBsAg), we investigated the association of hepatitis B virus co-infection with APRI score. Using Kaplan-Meier analysis and Cox proportional hazards regression we determined the association of elevated APRI with death during ART. RESULTS Among 20,308 adults in the analysis cohort, 1,027 (5.1%) had significant liver fibrosis at ART initiation including 616 (3.0%) with cirrhosis. Risk factors for significant fibrosis or cirrhosis included male sex, BMI <18, WHO clinical stage 3 or 4, CD4+ count <200 cells/mm(3) , and tuberculosis. Among the 237 (1.2%) who were tested, HBsAg-positive patients had four times the odds (adjusted odds ratio, 4.15; 95% CI, 1.71-10.04) of significant fibrosis compared HBsAg-negatives. Both significant fibrosis (adjusted hazard ratio 1.41, 95% CI, 1.21-1.64) and cirrhosis (adjusted hazard ratio 1.57, 95% CI, 1.31-1.89) were associated with increased all-cause mortality. CONCLUSION Liver fibrosis may be a risk factor for mortality during ART among HIV-infected individuals in Africa. APRI is an inexpensive and potentially useful test for liver fibrosis in resource-constrained settings. This article is protected by copyright. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The finite depth of field of a real camera can be used to estimate the depth structure of a scene. The distance of an object from the plane in focus determines the defocus blur size. The shape of the blur depends on the shape of the aperture. The blur shape can be designed by masking the main lens aperture. In fact, aperture shapes different from the standard circular aperture give improved accuracy of depth estimation from defocus blur. We introduce an intuitive criterion to design aperture patterns for depth from defocus. The criterion is independent of a specific depth estimation algorithm. We formulate our design criterion by imposing constraints directly in the data domain and optimize the amount of depth information carried by blurred images. Our criterion is a quadratic function of the aperture transmission values. As such, it can be numerically evaluated to estimate optimized aperture patterns quickly. The proposed mask optimization procedure is applicable to different depth estimation scenarios. We use it for depth estimation from two images with different focus settings, for depth estimation from two images with different aperture shapes as well as for depth estimation from a single coded aperture image. In this work we show masks obtained with this new evaluation criterion and test their depth discrimination capability using a state-of-the-art depth estimation algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The copy number variation (CNV) in beta-defensin genes (DEFB) on human chromosome 8p23 has been proposed to contribute to the phenotypic differences in inflammatory diseases. However, determination of exact DEFB CN is a major challenge in association studies. Quantitative real-time PCR (qPCR), paralog ratio tests (PRT) and multiplex ligation-dependent probe amplification (MLPA) have been extensively used to determine DEFB CN in different laboratories, but inter-method inconsistencies were observed frequently. In this study we asked which one is superior among the three methods for DEFB CN determination. RESULTS We developed a clustering approach for MLPA and PRT to statistically correlate data from a single experiment. Then we compared qPCR, a newly designed PRT and MLPA for DEFB CN determination in 285 DNA samples. We found MLPA had the best convergence and clustering results of the raw data and the highest call rate. In addition, the concordance rates between MLPA or PRT and qPCR (32.12% and 37.99%, respectively) were unacceptably low with underestimated CN by qPCR. Concordance rate between MLPA and PRT (90.52%) was high but PRT systematically underestimated CN by one in a subset of samples. In these samples a sequence variant which caused complete PCR dropout of the respective DEFB cluster copies was found in one primer binding site of one of the targeted paralogous pseudogenes. CONCLUSION MLPA is superior to PRT and even more to qPCR for DEFB CN determination. Although the applied PRT provides in most cases reliable results, such a test is particularly sensitive to low-frequency sequence variations preferably accumulating in loci like pseudogenes which are most likely not under selective pressure. In the light of the superior performance of multiplex assays, the drawbacks of such single PRTs could be overcome by combining more test markers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the developments of a neutron tomography setup at the instrument for prompt gamma-ray activation analysis (PGAA) at the Maier-Leibnitz Zentrum(MLZ). The recent developments are driven by the idea of combining the spatial information obtained with neutron tomography with the elemental information determined with PGAA, i.e. to further combine both techniques to an investigative technique called prompt gamma activation imaging (PGAI).At the PGAA instrument, a cold neutron flux of up to 6 x 1010 cm-2 s-1 (thermal equivalent) is available in the focus of an elliptically tapered neutron guide. In the reported experiments, the divergence of the neutron beam was investigated, the resolution of the installed detector system tested, and a proof-of-principle tomography experiment performed. In our study a formerly used camera box was upgraded with a better camera and an optical resolution of 8 line pairs/mm was achieved. The divergence of the neutron beam was measured by a systematic scan along the beam axis. Based on the acquired data, a neutron imaging setup with a L/D ratio of 200 was installed. The resolution of the setup was testedin combination with a gadolinium test target and different scintillator screens. The test target was irradiated at two positions to determine the maximum resolution and the resolution at the actual sample position. The performance of the installed tomography setup was demonstrated bya tomography experiment of an electric amplifier tube.