139 resultados para Radiological reporting

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radiological depiction of stab wounds in soft-tissues using multislice computed tomography is difficult and the hereby obtained images often lack contrast. To overcome these shortcomings we tried a new method. We gently instilled the contrast medium Lipiodol((R)) Ultra-fluide into five experimentally induced stab wounds on a pork haunch. Subsequent MSCT reconstructions of the wounds delivered clear, for medical laymen easily appreciable images regarding the stab direction and the stab depth. We believe that this easy and rapid technique can be useful in the examination of stab wounds in living and dead victims of sharp trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physicians treating patients with posterior circulation strokes (PCS) tended to debate more on whether or not to introduce anticoagulation rather than performing investigations to identify stroke aetiology, as in patients with anterior circulation strokes (ACS). Recent findings suggest that stroke aetiologies of PCS and ACS are more alike than dissimilar, suggesting that PCS deserve the same investigations as ACS. The characteristics and current diagnostic evaluation between patients with PCS and ACS were compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retrospective case-referent study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Overwhelming evidence shows the quality of reporting of randomised controlled trials (RCTs) is not optimal. Without transparent reporting, readers cannot judge the reliability and validity of trial findings nor extract information for systematic reviews. Recent methodological analyses indicate that inadequate reporting and design are associated with biased estimates of treatment effects. Such systematic error is seriously damaging to RCTs, which are considered the gold standard for evaluating interventions because of their ability to minimise or avoid bias. A group of scientists and editors developed the CONSORT (Consolidated Standards of Reporting Trials) statement to improve the quality of reporting of RCTs. It was first published in 1996 and updated in 2001. The statement consists of a checklist and flow diagram that authors can use for reporting an RCT. Many leading medical journals and major international editorial groups have endorsed the CONSORT statement. The statement facilitates critical appraisal and interpretation of RCTs. During the 2001 CONSORT revision, it became clear that explanation and elaboration of the principles underlying the CONSORT statement would help investigators and others to write or appraise trial reports. A CONSORT explanation and elaboration article was published in 2001 alongside the 2001 version of the CONSORT statement. After an expert meeting in January 2007, the CONSORT statement has been further revised and is published as the CONSORT 2010 Statement. This update improves the wording and clarity of the previous checklist and incorporates recommendations related to topics that have only recently received recognition, such as selective outcome reporting bias. This explanatory and elaboration document-intended to enhance the use, understanding, and dissemination of the CONSORT statement-has also been extensively revised. It presents the meaning and rationale for each new and updated checklist item providing examples of good reporting and, where possible, references to relevant empirical studies. Several examples of flow diagrams are included. The CONSORT 2010 Statement, this revised explanatory and elaboration document, and the associated website (www.consort-statement.org) should be helpful resources to improve reporting of randomised trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Overwhelming evidence shows the quality of reporting of randomised controlled trials (RCTs) is not optimal. Without transparent reporting, readers cannot judge the reliability and validity of trial findings nor extract information for systematic reviews. Recent methodological analyses indicate that inadequate reporting and design are associated with biased estimates of treatment effects. Such systematic error is seriously damaging to RCTs, which are considered the gold standard for evaluating interventions because of their ability to minimise or avoid bias. A group of scientists and editors developed the CONSORT (Consolidated Standards of Reporting Trials) statement to improve the quality of reporting of RCTs. It was first published in 1996 and updated in 2001. The statement consists of a checklist and flow diagram that authors can use for reporting an RCT. Many leading medical journals and major international editorial groups have endorsed the CONSORT statement. The statement facilitates critical appraisal and interpretation of RCTs. During the 2001 CONSORT revision, it became clear that explanation and elaboration of the principles underlying the CONSORT statement would help investigators and others to write or appraise trial reports. A CONSORT explanation and elaboration article was published in 2001 alongside the 2001 version of the CONSORT statement. After an expert meeting in January 2007, the CONSORT statement has been further revised and is published as the CONSORT 2010 Statement. This update improves the wording and clarity of the previous checklist and incorporates recommendations related to topics that have only recently received recognition, such as selective outcome reporting bias. This explanatory and elaboration document-intended to enhance the use, understanding, and dissemination of the CONSORT statement-has also been extensively revised. It presents the meaning and rationale for each new and updated checklist item providing examples of good reporting and, where possible, references to relevant empirical studies. Several examples of flow diagrams are included. The CONSORT 2010 Statement, this revised explanatory and elaboration document, and the associated website (www.consort-statement.org) should be helpful resources to improve reporting of randomised trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, every physician has the right to report a patient that is potentially unfit to drive to the licensing authority without violating medical confidentiality. Verified information regarding physicians' attitudes concerning this discretionary reporting and the frequency of such reports are not available. In order to answer these questions, 635 resident physicians were sent a questionnaire. The response rate was 52%. On average, the responding physicians--for all specialties--reported 0.31 patients (SD 0.64, 95% CI 0.24-0.38) in the year before the survey and 1.00 patient (SD 1.74, 95% CI 0.81-1.20) in the past 5 years. Seventy-nine percent of the responding physicians indicated knowing the current legal requirements for driving in Switzerland. In applied logistic regression analysis, only two factors correlate significantly with reporting: male sex (odds ratio 5.4) and the specialty "general medicine" (odds ratio 3.4). Ninety-seven percent of the physicians were against abolishing medical discretionary reporting and 29% were in favor of introducing mandatory reporting. The great majority of the questioned physicians supported the discretionary reporting of drivers that are potentially unfit to drive as currently practiced in Switzerland. The importance and the necessity of a regular traffic medicine-related continuing education for medical professionals are shown by the low number of reports per physician.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Critical incident reporting alone does not necessarily improve patient safety or even patient outcomes. Substantial improvement has been made by focusing on the further two steps of critical incident monitoring, that is, the analysis of critical incidents and implementation of system changes. The system approach to patient safety had an impact on the view about the patient's role in safety. This review aims to analyse recent advances in the technique of reporting, the analysis of reported incidents, and the implementation of actual system improvements. It also explores how families should be approached about safety issues. RECENT FINDINGS: It is essential to make as many critical incidents as possible known to the intensive care team. Several factors have been shown to increase the reporting rate: anonymity, regular feedback about the errors reported, and the existence of a safety climate. Risk scoring of critical incident reports and root cause analysis may help in the analysis of incidents. Research suggests that patients can be successfully involved in safety. SUMMARY: A persisting high number of reported incidents is anticipated and regarded as continuing good safety culture. However, only the implementation of system changes, based on incident reports, and also involving the expertise of patients and their families, has the potential to improve patient outcome. Hard outcome criteria, such as standardized mortality ratio, have not yet been shown to improve as a result of critical incident monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To establish an education and training programme for the reduction of CT radiation doses and to assess this programme's efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this article was to record reporting characteristics related to study quality of research published in major specialty dental journals with the highest impact factor (Journal of Endodontics, Journal of Oral and Maxillofacial Surgery, American Journal of Orthodontics and Dentofacial Orthopedics; Pediatric Dentistry, Journal of Clinical Periodontology, and International Journal of Prosthetic Dentistry). The included articles were classified into the following 3 broad subject categories: (1) cross-sectional (snap-shot), (2) observational, and (3) interventional. Multinomial logistic regression was conducted for effect estimation using the journal as the response and randomization, sample calculation, confounding discussed, multivariate analysis, effect measurement, and confidence intervals as the explanatory variables. The results showed that cross-sectional studies were the dominant design (55%), whereas observational investigations accounted for 13%, and interventions/clinical trials for 32%. Reporting on quality characteristics was low for all variables: random allocation (15%), sample size calculation (7%), confounding issues/possible confounders (38%), effect measurements (16%), and multivariate analysis (21%). Eighty-four percent of the published articles reported a statistically significant main finding and only 13% presented confidence intervals. The Journal of Clinical Periodontology showed the highest probability of including quality characteristics in reporting results among all dental journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to search the orthodontic literature and determine the frequency of reporting of confidence intervals (CIs) in orthodontic journals with an impact factor. The six latest issues of the American Journal of Orthodontics and Dentofacial Orthopedics, the European Journal of Orthodontics, and the Angle Orthodontist were hand searched and the reporting of CIs, P values, and implementation of univariate or multivariate statistical analyses were recorded. Additionally, studies were classified according to the type/design as cross-sectional, case-control, cohort, and clinical trials, and according to the subject of the study as growth/genetics, behaviour/psychology, diagnosis/treatment, and biomaterials/biomechanics. The data were analyzed using descriptive statistics followed by univariate examination of statistical associations, logistic regression, and multivariate modelling. CI reporting was very limited and was recorded in only 6 per cent of the included published studies. CI reporting was independent of journal, study area, and design. Studies that used multivariate statistical analyses had a higher probability of reporting CIs compared with those using univariate statistical analyses. Misunderstanding of the use of P values and CIs may have important implications in implementation of research findings in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.