73 resultados para Radiofrequency signals

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a geospatial model to predict the radiofrequency electromagnetic field from fixed site transmitters for use in epidemiological exposure assessment. The proposed model extends an existing model toward the prediction of indoor exposure, that is, at the homes of potential study participants. The model is based on accurate operation parameters of all stationary transmitters of mobile communication base stations, and radio broadcast and television transmitters for an extended urban and suburban region in the Basel area (Switzerland). The model was evaluated by calculating Spearman rank correlations and weighted Cohen's kappa (kappa) statistics between the model predictions and measurements obtained at street level, in the homes of volunteers, and in front of the windows of these homes. The correlation coefficients of the numerical predictions with street level measurements were 0.64, with indoor measurements 0.66, and with window measurements 0.67. The kappa coefficients were 0.48 (95%-confidence interval: 0.35-0.61) for street level measurements, 0.44 (95%-CI: 0.32-0.57) for indoor measurements, and 0.53 (95%-CI: 0.42-0.65) for window measurements. Although the modeling of shielding effects by walls and roofs requires considerable simplifications of a complex environment, we found a comparable accuracy of the model for indoor and outdoor points.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiofrequency neurotomy is a recognized treatment for cervical zygapophysial joint pain. In several studies, the method has provided complete pain relief in 60-70% of the patients for approximately 9 months. The validated technique has the disadvantage of procedural times of 2-4 hours because several lesions are performed to take into account the variable nerve course. We tested the hypothesis that ultrasound localization of the nerves would enable us to reduce the number of lesions performed, while reaching the benchmark of at least 80% pain relief in 80% of patients with a median duration of 35 weeks, as achieved by a previous investigation using the standard method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims Radiofrequency denervation (RF) of the lumbar facet joints has been shown to be effective in well-selected patients. However, long-term success varies between studies. We evaluated the influence of selected psychosocial and constitutional factors on the outcome of RF, expressed as the duration of pain relief. Methods This prospective observational study included 44 patients who received RF denervations at the University Hospital of Berne. Success was defined as at least 50% pain reduction 7–21 days, 6 months and 1 year after RF therapy. The Cox-regression analysis was performed to evaluate the influence of the following factors on the duration of success: age, sex, depression, work inability and previous surgery. Results Complete follow-up was available for 41 patients. The success rate 7–21 days after the denervation was 76%. It decreased to 32% at 6 months and to 22% at 1 year. The median success duration was 17 weeks (95% CI 10–26). The Cox-regression analysis showed a significant shorter duration of success for patients with depression (hazard ratio [HR] 2.97, 95% CI 1.32–6.65), previous surgery (HR 2.39, 95% CI 1.10–5.21) and number of treated joints (HR 1.95 for each increase in the number of joints, 95% CI 1.14–3.33). In bivariate analyses, only depression was kept to be significant. Conclusions Depression seems to be related with a short duration of success. Based on these findings, a comprehensive study is warranted to evaluate whether psychosocial factors have to be considered when recruiting patients for radiofrequency denervation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What's known on the subject? And what does the study add? We have previously shown that percutaneous radiofrequency ablation guided by image-fusion technology allows for precise needle placement with real time ultrasound superimposed with pre-loaded imaging, removing the need for real-time CT or MR guidance. Emerging technology also allows real-time tracking of a treatment needle within an organ in a virtually created 3D format. To our knowledge, this is the first study utilising a sophisticated ultrasound-based navigation system that uses both image-fusion and real-time probe-tracking technologies for in-vivo renal ablative intervention.