6 resultados para Radiance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the efficacy and safety of ranibizumab 0.5 mg, guided by visual acuity (VA) stabilization or disease activity criteria, versus verteporfin photodynamic therapy (vPDT) in patients with visual impairment due to myopic choroidal neovascularization (CNV). DESIGN Phase III, 12-month, randomized, double-masked, multicenter, active-controlled study. PARTICIPANTS Patients (N = 277) with visual impairment due to myopic CNV. METHODS Patients were randomized to receive ranibizumab on day 1, month 1, and thereafter as needed guided by VA stabilization criteria (group I, n = 106); ranibizumab on day 1 and thereafter as needed guided by disease activity criteria (group II, n = 116); or vPDT on day 1 and disease activity treated with ranibizumab or vPDT at investigators' discretion from month 3 (group III, n = 55). MAIN OUTCOME MEASURES Mean average best-corrected visual acuity (BCVA) change from baseline to month 1 through months 3 (primary) and 6, mean BCVA change and safety over 12 months. RESULTS Ranibizumab treatment in groups I and II was superior to vPDT based on mean average BCVA change from baseline to month 1 through month 3 (group I: +10.5, group II: +10.6 vs. group III: +2.2 Early Treatment Diabetic Retinopathy Study [ETDRS] letters; both P< 0.0001). Ranibizumab treatment guided by disease activity was noninferior to VA stabilization-guided retreatment based on mean average BCVA change from baseline to month 1 through month 6 (group II: +11.7 vs. group I: +11.9 ETDRS letters; P< 0.00001). Mean BCVA change from baseline to month 12 was +13.8 (group I), +14.4 (group II), and +9.3 ETDRS letters (group III). At month 12, 63.8% to 65.7% of patients showed resolution of myopic CNV leakage. Patients received a median of 4.0 (group I) and 2.0 (groups II and III) ranibizumab injections over 12 months. No deaths or cases of endophthalmitis and myocardial infarction occurred. CONCLUSIONS Ranibizumab treatment, irrespective of retreatment criteria, provided superior BCVA gains versus vPDT up to month 3. Ranibizumab treatment guided by disease activity criteria was noninferior to VA stabilization criteria up to month 6. Over 12 months, individualized ranibizumab treatment was effective in improving and sustaining BCVA and was generally well tolerated in patients with myopic CNV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofísica de Andalucía (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infra-red (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context. The Rosetta mission of the European Space Agency has been orbiting the comet 67P/Churyumov-Gerasimenko (67P) since August 2014 and is now in its escort phase. A large complement of scientific experiments designed to complete the most detailed study of a comet ever attempted are onboard Rosetta. Aims. We present results for the photometric and spectrophotometric properties of the nucleus of 67P derived from the OSIRIS imaging system, which consists of a Wide Angle Camera (WAC) and a Narrow Angle Camera (NAC). The observations presented here were performed during July and the beginning of August 2014, during the approach phase, when OSIRIS was mapping the surface of the comet with several filters at different phase angles (1.3 degrees-54 degrees). The resolution reached up to 2.1 m/px. Methods. The OSIRIS images were processed with the OSIRIS standard pipeline, then converted into I/F. radiance factors and corrected for the illumination conditions at each pixel using the Lommel-Seeliger disk law. Color cubes of the surface were produced by stacking registered and illumination-corrected images. Furthermore, photometric analysis was performed both on disk-averaged photometry in several filters and on disk-resolved images acquired with the NAC orange filter, centered at 649 ran, using Hapke modeling. Results. The disk-averaged phase function of the nucleus of 67P shows a strong opposition surge with a G parameter value of -0.13 +/- 0.01 in the HG system formalism and an absolute magnitude H-v(1, 1, 0) = 15.74 +/- 0.02 mag. The integrated spectrophotometry in 20 filters covering the 250-1000 nm wavelength range shows a red spectral behavior, without clear absorption bands except for a potential absorption centered at similar to 290 rim that is possibly due to SO2 ice. The nucleus shows strong phase reddening, with disk-averaged spectral slopes increasing from 11%/( 100 nm) to 16%/(100 nm) in the 1.3 degrees-54 degrees phase angle range. The geometric albedo of the comet is 6.5 +/- 0.2% at 649 nm, with local variations of up to similar to 16% in the Hapi region. From the disk-resolved images we computed the spectral slope together with local spectrophotometry and identified three distinct groups of regions (blue, moderately red, and red). The Hapi region is the brightest, the bluest in term of spectral slope, and the most active surface on the comet. Local spectrophotometry shows an enhancement of the flux in the 700-750 nm that is associated with coma emissions.