60 resultados para REMOVAL TORQUE

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enhancing osseointegration through surface immobilization of multiple short peptide sequences that mimic extracellular matrix (ECM) proteins, such as arginine-glycine-aspartic acid (RGD) and lysine-arginine-serine-arginine (KRSR), has not yet been extensively explored. Additionally, the effect of biofunctionalizing chemically modified sandblasted and acid-etched surfaces (modSLA) is unknown. The present study evaluated modSLA implant surfaces modified with RGD and KRSR for potentially enhanced effects on bone apposition and interfacial shear strength during early stages of bone regeneration. Two sets of experimental implants were placed in the maxillae of eight miniature pigs, known for their rapid wound healing kinetics: bone chamber implants creating two circular bone defects for histomorphometric analysis on one side and standard thread configuration implants for removal torque testing on the other side. Three different biofunctionalized modSLA surfaces using poly-L-lysine-graft-poly(ethylene glycol) (PLL-g-PEG) as a carrier minimizing nonspecific protein adsorption [(i) 20 pmol cm⁻² KRSR alone (KRSR); or in combination with RGD in two different concentrations; (ii) 0.05 pmol cm⁻² RGD (KRSR/RGD-1); (iii) 1.26 pmol cm⁻² RGD (KRSR/RGD-2)] were compared with (iv) control modSLA. Animals were sacrificed at 2 weeks. Removal torque values (701.48-780.28 N mm), bone-to-implant contact (BIC) (35.22%-41.49%), and new bone fill (28.58%-30.62%) demonstrated no significant differences among treatments. It may be concluded that biofunctionalizing modSLA surfaces with KRSR and RGD derivatives of PLL-g-PEG polymer does not increase BIC, bone fill, or interfacial shear strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. Methods Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. Results Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. Conclusion This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design. Materials and Methods: Dental implants with the same geometry but with 6 different surface treatments were tested in vivo in a sheep model (pelvis). Peri-implant bone density and removal torque were compared at 2, 4, and 8 weeks after implantation. Implant surfaces tested were: sandblasted and acid-etched titanium (Ti), sandblasted and etched zirconia, Ti coated with calcium phosphate (CaP), Ti modified via anodic plasma-chemical treatment (APC), bisphosphonate-coated Ti (Ti + Bisphos), and Ti coated with collagen containing chondroitin sulfate (CS). Results: All dental implants were well integrated at the time of sacrifice. There were no significant differences observed in peri-implant bone density between implant groups. After 8 weeks of healing, removal torque values for Ti, Ti + CaP, Ti + Bisphos, and Ti + collagen + CS were significantly higher than those for zirconia and Ti + APC. Conclusions: Whereas the sandblasted/acid-etched Ti implant can still be considered the reference standard surface for dental implants, functional surface modifications such as bisphosphonate or collagen coating seem to enhance early peri-implant bone formation and should be studied further.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The removal of nonretrievable implant components represents a challenge in implant dentistry. The mechanical approach involves the risk of damaging the implant connection or the bone-to-implant interface. This case report describes a cryo-mechanical approach for the safe removal of a nonretrievable implant component. A patient had an implant surgically placed in a private practice. When the patient returned to the restorative dentist to make a definitive impression, the healing abutment could not be loosened. The patient was referred to the Division of Fixed Prosthodontics (University of Bern, Switzerland), where the stripped screw hole was enlarged with a special drill from a service kit of the implant provider. Although an extraction bolt was screwed into the opening and the torque ratchet was activated, the healing abutment would not loosen. A novel approach was attempted whereby the healing abutment was cooled with dry ice (CO2). The cooling effect seemingly caused shrinkage of the healing abutment and a reduction of the connection forces between the implant and the nonretrievable component. The approach of creating an access hole for the application of reverse torque via the extraction bolt in combination with the thermal effect led to the successful removal of the blocked component. Neither the implant connection nor the bone-to-implant interface was damaged. The combined cryo-mechanical procedure allowed the implant to be successfully restored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Removal of miniplates is a controversial topic in oral and maxillofacial surgery. Originally, miniplates were designed to be removed on completion of bone healing. The introduction of low profile titanium miniplates has led to the routine removal of miniplates becoming comparatively rare in many parts of the world. Few studies have investigated the reasons for non-routine removal of miniplates and the factors that affect osteosynthesis after osteotomy in large numbers of patients. The aim of the present study was to investigate complications related to osteosynthesis after bilateral sagittal split osteotomy (BSSO) in a large number (n=153) of patients. In addition to the rates of removal, emphasis was placed on investigating the reasons and risk factors associated with symptomatic miniplate removal. The rate of plate removal per patient was 18.6%, the corresponding rate per plate being 18.2%. Reasons for plate removal included plate-related complications in 16 patients and subjective discomfort in 13 patients. Half of the plates were removed during the first postoperative year. Smoking was the only significant predictor for plate removal. Patients undergoing orthognathic surgery should be screened with regard to smoking and encouraged and assisted to cease smoking, at least perioperatively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the efficiency of air abrasion on enamel caries with selective enamel powder (SEP) or with alumina powder and a negative and positive control group. Ninety-three extracted molars with non-cavitated incipient enamel lesions were selected. After embedding the roots in resin, each lesion was sectioned perpendicular to the surface and photographed. Each lesion was classified microscopically as having or not having dentin involvement. The lesions were distributed into four groups with an equal number of enamel caries with or without dentin involvement. Each group was treated differently: Group 1 had SEP abrasion, Group 2 had alumina abrasion, Group 3 had sodium bicarbonate abrasion (negative control) and Group 4 had bur treatment (positive control). The surface was rephotographed after treatment. Superimposition of the photographs identified areas of "correct-excavation," "under-excavation" and "over-excavation." There were no statistical differences between lesions treated with or without dentin involvement for Groups 2 through 4. However, in the SEP group, all measured areas were significantly influenced by dentin involvement. In pairwise comparisons, no statistical differences were found between the alumina and bur groups. The SEP group, however, showed statistically significant differences for each area compared to the alumina group in enamel caries without dentin involvement. SEP performed as well as alumina and bur in lesions with dentin involvement. SEP is different in its ablative properties toward caries with dentin involvement or no dentin involvement. In terms of dental treatment, SEP seems to have a diagnostic potential for enamel lesions before operative intervention in patients with high caries risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinically, the displacement of intravertebral fat into the circulation during vertebroplasty is reported to lead to problems in elderly patients and can represent a serious complication, especially when multiple levels have to be treated. An in vitro study has shown the feasibility of removing intravertebral fat by pulsed jet-lavage prior to vertebroplasty, potentially reducing the embolization of bone marrow fat from the vertebral bodies and alleviating the cardiovascular changes elicited by pulmonary fat embolism. In this in vivo study, percutaneous vertebroplasty using polymethylmethacrylate (PMMA) was performed in three lumbar vertebrae of 11 sheep. In six sheep (lavage group), pulsed jet-lavage was performed prior to injection of PMMA compared to the control group of five sheep receiving only PMMA vertebroplasty. Invasive recording of blood pressures was performed continuously until 60 min after the last injection. Cardiac output and arterial blood gas parameters were measured at selected time points. Post mortem, the injected cement volume was measured using CT and lung biopsies were processed for assessment of intravascular fat. Pulsed jet-lavage was feasible in the in vivo setting. In the control group, the injection of PMMA resulted in pulmonary fat embolism and a sudden and significant increase in mean pulmonary arterial pressure. Pulsed jet-lavage prevented any cardiovascular changes and significantly reduced the severity of bone marrow fat embolization. Even though significantly more cement had been injected into the lavaged vertebral bodies, significantly fewer intravascular fat emboli were identified in the lung tissue. Pulsed jet-lavage prevented the cardiovascular complications after PMMA vertebroplasty in sheep and alleviated the severity of pulmonary fat embolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical and radiologic outcome analysis after petrous bone cholesteatoma (PBC) removal with simultaneous functional reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic concentrations of interleukin-6 (IL-6) are elevated in patients with liver cirrhosis, and impaired hepatic uptake of IL-6 was suggested to contribute to higher levels in these patients. To test this hypothesis IL-6 was measured in portal venous serum (PVS), hepatic venous serum (HVS) and systemic venous serum (SVS) of 41 patients with liver cirrhosis and four patients with normal liver function. IL-6 was higher in PVS than HVS of all blood donors and about 43% of portal vein derived IL-6 was extracted by the healthy liver, and 6.3% by the cirrhotic liver demonstrating markedly impaired removal of IL-6 by the latter. Whereas in patients with CHILD-PUGH stage A IL-6 in HVS was almost 25% lower than in PVS, in patients with CHILD-PUGH stage C IL-6 was similarly abundant in the two blood compartments. Ascites is a common complication in cirrhotic patients and was associated with higher IL-6 levels in all blood compartments without significant differences in hepatic excretion. Hepatic venous pressure gradient did not correlate with the degree of hepatic IL-6 removal excluding hepatic shunting as the principal cause of impaired IL-6 uptake. Furthermore, patients with alcoholic liver cirrhosis had higher IL-6 in all blood compartments than patients with cryptogenic liver cirrhosis. Aetiology of liver cirrhosis did not affect hepatic removal rate indicating higher IL-6 synthesis in patients with alcoholic liver cirrhosis. In summary, the current data provide evidence that impaired hepatic removal of IL-6 is explained by hepatic shunting and liver dysfunction in patients with liver cirrhosis partly explaining higher systemic levels.