2 resultados para REINFORCED POLY(EPSILON-CAPROLACTONE) BIOCOMPOSITES
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Indocyanine green (ICG) is a chemically labile compound which needs to be stabilized in aqueous media to be used in biomedical applications. In the present study, poly(ε-caprolactone) (PCL), a semi-crystalline polyester, was used to encapsulate and stabilize ICG in a hydrophobic environment. A hydrophobic and biocompatible nanocomposite was obtained by the process of encapsulating inorganic silica. ICG was embedded in the hydrophobic polymer coating by starting from a well-defined silica (Si) core of either 80 nm or 120 nm diameter, which served as a template for a ‘grafting from’ approach using ε-caprolactone. The obtained nanocomposite Si grafted PCL/ICG was based on silica nanoparticles grafted with PCL, in which ICG was adsorbed. The nanoparticles were characterized by IR spectroscopy, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The change in the surface charge and the colloidal stability of the nanoparticles was followed by zeta potential measurements. This approach of synthesizing nanocomposite-based ICG demonstrates a new route to stabilize ICG. We synthesized biocompatible nanoparticles containing a high ICG concentration and exhibiting excellent stability to aqueous decomposition.
Resumo:
The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7 ± 12.2; 53.3 ± 9.0 %) and SE-PSD (46.7 ± 4.5; 61.7 ± 4.9 %) as well as AM implants (20.49 ± 5.1; 43.9 ± 9.7 %) and AM-PSD implants (19.7 ± 3.5; 48.3 ± 15.6 %) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.