6 resultados para REFRACTIVE-INDEXES

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Refractive losses in laser-produced plasmas used as gain media are caused by electron density gradients, and limit the energy transport range. The pump pulse is thus deflected from the high-gain region and the short wavelength laser signal also steers away, causing loss of collimation. A Hohlraum used as a target makes the plasma homogeneous and can mitigate refractive losses by means of wave-guiding. A computational study combining a hydrodynamics code and an atomic physics code is presented, which includes a ray-tracing modeling based on the eikonal theory of the trajectory equation. This study presents gain calculations based on population inversion produced by free-electron collisions exciting bound electrons into metastable levels in the 3d94d1(J = 0) → 3d94p1(J = 1) transition of Ni-like Sn. Further, the Hohlraum suggests a dramatic enhancement of the conversion efficiency of collisionally excited x-ray lasing for Ni-like Sn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.