31 resultados para RATE-CONSTANT METHOD

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The pharmacokinetics of ketamine and norketamine enantiomers after administration of intravenous (IV) racemic ketamine (R-/S-ketamine; 2.2mg/kg) or S-ketamine (1.1mg/kg) to five ponies sedated with IV xylazine (1.1mg/kg) were compared. The time intervals to assume sternal and standing positions were recorded. Arterial blood samples were collected before and 1, 2, 4, 6, 8 and 13min after ketamine administration. Arterial blood gases were evaluated 5min after ketamine injection. Plasma concentrations of ketamine and norketamine enantiomers were determined by capillary electrophoresis and were evaluated by non-linear least square regression analysis applying a monocompartmental model. The first-order elimination rate constant was significantly higher and elimination half-life and mean residence time were lower for S-ketamine after S-ketamine compared to R-/S-ketamine administration. The maximum concentration of S-norketamine was higher after S-ketamine administration. Time to standing position was significantly diminished after S-ketamine compared to R-/S-ketamine. Blood gases showed low-degree hypoxaemia and hypercarbia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate pharmacokinetics of ketamine and norketamine enantiomers after constant rate infusion (CRI) of a subanesthetic dose of racemic ketamine or S-ketamine in ponies. ANIMALS: Five 6-year-old Shetland pony geldings that weighed between 101 and 152 kg. PROCEDURES: In a crossover study, each pony received a CRI of racemic ketamine (loading dose, 0.6 mg/kg; CRI, 0.02 mg/kg/min) and S-ketamine (loading dose, 0.3 mg/kg; CRI, 0.01 mg/kg/min), with a 1-month interval between treatments. Arterial blood samples were collected before and at 5, 15, 30, 45, and 60 minutes during drug administration and at 5, 10, 30, and 60 minutes after discontinuing the CRI. Plasma ketamine and norketamine enantiomers were quantified by use of capillary electrophoresis. Individual R-ketamine and S-ketamine concentration-versus-time curves were analyzed by use of a monocompartmental model. Plasma disposition curves for R-norketamine and S-norketamine were described by estimating the area under the concentration-versus-time curve (AUC), maximum concentration (Cmax), and time until Cmax. RESULTS: Plasma concentrations of S-ketamine decreased and biodegradation products increased more rapidly after S-ketamine CRI, compared with results after racemic ketamine CRI. The R-norketamine was eliminated faster than was the S-norketamine. Significant differences between treatments were found for the AUC of S-ketamine and within the racemic ketamine CRI for the AUC and Cmax of norketamine isomers. CONCLUSIONS AND CLINICAL RELEVANCE: CRI of S-ketamine may be preferable over CRI of racemic ketamine in standing equids because the S-enantiomer was eliminated faster when infused alone instead of as part of a racemic mixture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study quantitatively investigated the analgesic action of a low-dose constant-rate-infusion (CRI) of racemic ketamine (as a 0.5 mg kg(-1) bolus and at a dose rate of 10 microg kg(-1) min(-1)) in conscious dogs using a nociceptive withdrawal reflex (NWR) and with enantioselective measurement of plasma levels of ketamine and norketamine. Withdrawal reflexes evoked by transcutaneous single and repeated electrical stimulation (10 pulses, 5 Hz) of the digital plantar nerve were recorded from the biceps femoris muscle using surface electromyography. Ketamine did not affect NWR thresholds or the recruitment curves after a single nociceptive stimulation. Temporal summation (as evaluated by repeated stimuli) and the evoked behavioural response scores were however reduced compared to baseline demonstrating the antinociceptive activity of ketamine correlated with the peak plasma concentrations. Thereafter the plasma levels at pseudo-steady-state did not modulate temporal summation. Based on these experimental findings low-dose ketamine CRI cannot be recommended for use as a sole analgesic in the dog.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dexmedetomidine and lignocaine IV are used clinically to provide analgesia in horses. The aims of this study were to investigate the antinociceptive effects, plasma concentrations and sedative effects of 2, 4 and 6 µg/kg/h dexmedetomidine IV, with a bolus of 0.96 µg/kg preceding each continuous rate infusion (CRI), and 20, 40 and 60 µg/kg/min lignocaine IV, with a bolus of 550 µg/kg preceding each CRI, in 10 Swiss Warmblood horses. Electrically elicited nociceptive withdrawal reflexes were evaluated by deltoid muscle electromyography. Nociceptive threshold and tolerance were determined by electromyography and behaviour following single and repeated stimulation. Plasma concentrations of drugs were determined by liquid chromatography and mass spectrometry. Sedation was scored on a visual analogue scale. Dexmedetomidine increased nociceptive threshold to single and repeated stimulation for all CRIs, except at 2 µg/kg/h, where no increase in single stimulation nociceptive threshold was observed. Dexmedetomidine increased nociceptive tolerance to single and repeated stimulation at all CRIs. There was large individual variability in dexmedetomidine plasma concentrations and levels of sedation; the median plasma concentration providing antinociceptive effects to all recorded parameters was 0.15 ng/mL, with a range from <0.02 ng/mL (below the lower limit of quantification) to 0.25 ng/mL. Lignocaine increased nociceptive threshold and tolerance to single and repeated stimulation at CRIs of 40 and 60 µg/kg/min, corresponding to plasma lignocaine concentrations >600 ng/mL. Only nociceptive tolerance to repeated stimulation increased at 20 µg/kg/min lignocaine. Lignocaine at 40 µg/kg/min and dexmedetomidine at 4 µg/kg/h were the lowest CRIs resulting in consistent antinociception. Lignocaine did not induce significant sedation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dexmedetomidine, the most selective α2 -adrenoceptor agonist in clinical use, is increasingly being used in both conscious and anaesthetized horses; however, the pharmacokinetics and sedative effects of this drug administered alone as an infusion are not previously described in horses. Seven horses received an infusion of 8 μg dexmedetomidine/kg/h for 150 min, venous blood samples were collected, and dexmedetomidine concentrations were assayed using liquid chromatography-mass spectrometry (LC/MS) and analyzed using noncompartmental pharmacokinetic analysis. Sedation was scored as the distance from the lower lip of the horse to the ground measured in centimetre. The harmonic mean (SD) plasma elimination half-life (Lambda z half-life) for dexmedetomidine was 20.9 (5.1) min, clearance (Cl) was 0.3 (0.20) L/min/kg, and volume of distribution at steady-state (Vdss ) was 13.7 (7.9) L/kg. There was a considerable individual variation in the concentration of dexmedetomidine vs. time profile. The level of sedation covaried with the plasma concentration of dexmedetomidine. This implies that for clinical use of dexmedetomidine constant rate infusion in conscious horses, infusion rates can be easily adjusted to effect, and this is preferable to an infusion at a predetermined value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. METHOD: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene's test, one and three-way ANOVA, and Tukey HSD test (alpha = 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Pelvic inflammatory disease (PID) results from the ascending spread of microorganisms from the vagina and endocervix to the upper genital tract. PID can lead to infertility, ectopic pregnancy and chronic pelvic pain. The timing of development of PID after the sexually transmitted bacterial infection Chlamydia trachomatis (chlamydia) might affect the impact of screening interventions, but is currently unknown. This study investigates three hypothetical processes for the timing of progression: at the start, at the end, or throughout the duration of chlamydia infection. Methods We develop a compartmental model that describes the trial structure of a published randomised controlled trial (RCT) and allows each of the three processes to be examined using the same model structure. The RCT estimated the effect of a single chlamydia screening test on the cumulative incidence of PID up to one year later. The fraction of chlamydia infected women who progress to PID is obtained for each hypothetical process by the maximum likelihood method using the results of the RCT. Results The predicted cumulative incidence of PID cases from all causes after one year depends on the fraction of chlamydia infected women that progresses to PID and on the type of progression. Progression at a constant rate from a chlamydia infection to PID or at the end of the infection was compatible with the findings of the RCT. The corresponding estimated fraction of chlamydia infected women that develops PID is 10% (95% confidence interval 7-13%) in both processes. Conclusions The findings of this study suggest that clinical PID can occur throughout the course of a chlamydia infection, which will leave a window of opportunity for screening to prevent PID.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was (1) to determine frequency and type of medication errors (MEs), (2) to assess the number of MEs prevented by registered nurses, (3) to assess the consequences of ME for patients, and (4) to compare the number of MEs reported by a newly developed medication error self-reporting tool to the number reported by the traditional incident reporting system. We conducted a cross-sectional study on ME in the Cardiovascular Surgery Department of Bern University Hospital in Switzerland. Eligible registered nurses (n = 119) involving in the medication process were included. Data on ME were collected using an investigator-developed medication error self reporting tool (MESRT) that asked about the occurrence and characteristics of ME. Registered nurses were instructed to complete a MESRT at the end of each shift even if there was no ME. All MESRTs were completed anonymously. During the one-month study period, a total of 987 MESRTs were returned. Of the 987 completed MESRTs, 288 (29%) indicated that there had been an ME. Registered nurses reported preventing 49 (5%) MEs. Overall, eight (2.8%) MEs had patient consequences. The high response rate suggests that this new method may be a very effective approach to detect, report, and describe ME in hospitals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetic nephropathy and end-stage renal failure are still a major cause of mortality amongst patients with diabetes mellitus (DM). In this study, we evaluated the Clinitek-Microalbumin (CM) screening test strip for the detection of microalbuminuria (MA) in a random morning spot urine in comparison with the quantitative assessment of albuminuria in the timed overnight urine collection ("gold standard"). One hundred thirty-four children, adolescents, and young adults with insulin-dependent DM Type 1 were studied at 222 outpatient visits. Because of urinary tract infection and/or haematuria, the data of 13 visits were excluded. Finally, 165 timed overnight urine were collected in the remaining 209 visits (79% sample per visit rate). Ten (6.1%) patients presented MA of > or =15 microg/min. In comparison however, 200 spot urine could be screened (96% sample/visit rate) yielding a significant increase in compliance and screening rate (P<.001, McNemar test). Furthermore, at 156 occasions, the gold standard and CM could be directly compared. The sensitivity and the specificity for CM in the spot urine (cut-off > or =30 mg albumin/l) were 0.89 [95% confidence interval (CI) 0.56-0.99] and 0.73 (CI 0.66-0.80), respectively. The positive and negative predictive value were 0.17 (CI 0.08-0.30) and 0.99 (CI 0.95-1.00), respectively. Considering CM albumin-to-creatinine ratio, the results were poorer than with the albumin concentration alone. Using CM instead of quantitative assessment of albuminuria is not cost-effective (35 US dollars versus 60 US dollars/patient/year). In conclusion, to exclude MA, the CM used in the random spot urine is reliable and easy to handle, but positive screening results of > or =30 mg albumin/l must be confirmed by analyses in the timed overnight collected urine. Although the screening compliance is improved, in terms of analysing random morning spot urine for MA, we cannot recommend CM in a paediatric diabetic outpatient setting because the specificity is far too low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI]=0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into account.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies on the effect of glycosylation on the elimination rate of antibodies have produced conflicting results. Here, we performed pharmacokinetic studies in mice with two preparations of a monoclonal IgG1 antibody enriched for complex type or high mannose type oligosaccharides at the Fc glycosylation site. No significant difference in the serum half-life was found between the two antibody glycoforms, nor was any difference observed in the serum half-lives of different complex type glycoforms. To evaluate the influence of glycosylation within the variable domain, a second monoclonal antibody, glycosylated in both the Fc and Fv domains, was separated into fractions containing different amounts of Fv-associated sialic acid and administered to mice. Again, no significant difference was found in the clearance rates of variants carrying different amounts of Fv-associated sialic acid or lacking Fv-glycosylation. These results suggest that glycosylation has little or no impact on the pharmacokinetic behavior of these two monoclonal antibodies in mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-resolution and highly precise age models for recent lake sediments (last 100–150 years) are essential for quantitative paleoclimate research. These are particularly important for sedimentological and geochemical proxies, where transfer functions cannot be established and calibration must be based upon the relation of sedimentary records to instrumental data. High-precision dating for the calibration period is most critical as it determines directly the quality of the calibration statistics. Here, as an example, we compare radionuclide age models obtained on two high-elevation glacial lakes in the Central Chilean Andes (Laguna Negra: 33°38′S/70°08′W, 2,680 m a.s.l. and Laguna El Ocho: 34°02′S/70°19′W, 3,250 m a.s.l.). We show the different numerical models that produce accurate age-depth chronologies based on 210Pb profiles, and we explain how to obtain reduced age-error bars at the bottom part of the profiles, i.e., typically around the end of the 19th century. In order to constrain the age models, we propose a method with five steps: (i) sampling at irregularly-spaced intervals for 226Ra, 210Pb and 137Cs depending on the stratigraphy and microfacies, (ii) a systematic comparison of numerical models for the calculation of 210Pb-based age models: constant flux constant sedimentation (CFCS), constant initial concentration (CIC), constant rate of supply (CRS) and sediment isotope tomography (SIT), (iii) numerical constraining of the CRS and SIT models with the 137Cs chronomarker of AD 1964 and, (iv) step-wise cross-validation with independent diagnostic environmental stratigraphic markers of known age (e.g., volcanic ash layer, historical flood and earthquakes). In both examples, we also use airborne pollutants such as spheroidal carbonaceous particles (reflecting the history of fossil fuel emissions), excess atmospheric Cu deposition (reflecting the production history of a large local Cu mine), and turbidites related to historical earthquakes. Our results show that the SIT model constrained with the 137Cs AD 1964 peak performs best over the entire chronological profile (last 100–150 years) and yields the smallest standard deviations for the sediment ages. Such precision is critical for the calibration statistics, and ultimately, for the quality of the quantitative paleoclimate reconstruction. The systematic comparison of CRS and SIT models also helps to validate the robustness of the chronologies in different sections of the profile. Although surprisingly poorly known and under-explored in paleolimnological research, the SIT model has a great potential in paleoclimatological reconstructions based on lake sediments