30 resultados para Quadrotor. Variable reference control. Position and orientation control. UAV s

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We analyzed more than 200 OSIRIS NAC images with a pixel scale of 0.9-2.4 m/pixel of comet 67P/Churyumov-Gerasimenko (67P) that have been acquired from onboard the Rosetta spacecraft in August and September 2014 using stereo-photogrammetric methods (SPG). We derived improved spacecraft position and pointing data for the OSIRIS images and a high-resolution shape model that consists of about 16 million facets (2 m horizontal sampling) and a typical vertical accuracy at the decimeter scale. From this model, we derive a volume for the northern hemisphere of 9.35 km(3) +/- 0.1 km(3). With the assumption of a homogeneous density distribution and taking into account the current uncertainty of the position of the comet's center-of-mass, we extrapolated this value to an overall volume of 18.7 km(3) +/- 1.2 km(3), and, with a current best estimate of 1.0 X 10(13) kg for the mass, we derive a bulk density of 535 kg/m(3) +/- 35 kg/m(3). Furthermore, we used SPG methods to analyze the rotational elements of 67P. The rotational period for August and September 2014 was determined to be 12.4041 +/- 0.0004 h. For the orientation of the rotational axis (z-axis of the body-fixed reference frame) we derived a precession model with a half-cone angle of 0.14 degrees, a cone center position at 69.54 degrees/64.11 degrees (RA/Dec J2000 equatorial coordinates), and a precession period of 10.7 days. For the definition of zero longitude (x-axis orientation), we finally selected the boulder-like Cheops feature on the big lobe of 67P and fixed its spherical coordinates to 142.35 degrees right-hand-rule eastern longitude and -0.28 degrees latitude. This completes the definition of the new Cheops reference frame for 67P. Finally, we defined cartographic mapping standards for common use and combined analyses of scientific results that have been obtained not only within the OSIRIS team, but also within other groups of the Rosetta mission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The taxonomic and phylogenetic status of Echinococcus granulosus strains are still controversial and under discussion. In the present study, we investigated the genetic polymorphism of E. granulosus isolates originating from three countries of Africa, including a region of Algeria, where the common G1 sheep and the camel G6 strains coexist sympatrically. Seventy-one hydatid cysts were collected from sheep, cattle, camels, and humans. Two mitochondrial markers (cox1 and nad1) were used for strain identification. Two nuclear markers (actII and hbx2) were used to study the possible occurrence of cross-fertilization. Despite the heterogeneity observed among the G1 isolates, they were all localized within one robust cluster. A second strong cluster was also observed containing all of the G6 isolates. Both strains appeared as two distinct groups, and no cases of interbreeding were found. Thus, the attribution of a species rank can be suggested. We also found the Tasmanian sheep G2 strain for the first time in Africa. Because of the slight variations observed between the common sheep and the Tasmanian sheep strains, further studies should be carried out to elucidate the epidemiological relevance of this genetic discrimination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In spinal muscular atrophy, the SMN1 gene is deleted or destroyed by mutation, while the neigbouring, nearly identical SMN2 gene acts as a partial functional substitute. However, due to a single nucleotide exchange, the seventh exon of SMN2 is mostly excluded from the mature mRNA, and the resulting shorter protein is non-functional. Here, we map the previously uncharacterised intron 6 branch point by RT-PCR. Moreover we show that exon 7 inclusion can be either abolished or improved by mutations in this branch site region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: We compared motor and movement thresholds to transcranial magnetic stimulation (TMS) in healthy subjects and investigated the effect of different coil positions on thresholds and MEP (motor-evoked potential) amplitudes. METHODS: The abductor pollicis brevis (APB) 'hot spot' and a standard scalp position were stimulated. APB resting motor threshold (APB MEP-MT) defined by the '5/10' electrophysiological method was compared with movement threshold (MOV-MT), defined by visualization of movements. Additionally, APB MEP-MTs were evaluated with the '3/6 method,' and MEPs were recorded at a stimulation intensity of 120% APB MEP-MT at each position. RESULTS: APB MEP-MTs were significantly lower by stimulation of the 'hot spot' than of the standard position, and significantly lower than MOV-MTs (n=15). There were no significant differences between the '3/6' and the '5/10' methods, or between APB MEP amplitudes by stimulating each position at 120% APB MEP-MT. CONCLUSIONS: Coil position and electrophysiological monitoring influenced motor threshold determinations. Performing 6 instead of 10 trials did not produce different threshold measurements. Adjustment of intensity according to APB MEP-MT at the stimulated position did not influence APB MEP amplitudes. SIGNIFICANCE: Standardization of stimulation positions, nomenclature and criteria for threshold measurements should be considered in design and comparison of TMS protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We develop statistical procedures for estimating shape and orientation of arbitrary three-dimensional particles. We focus on the case where particles cannot be observed directly, but only via sections. Volume tensors are used for describing particle shape and orientation, and we derive stereological estimators of the tensors. These estimators are combined to provide consistent estimators of the moments of the so-called particle cover density. The covariance structure associated with the particle cover density depends on the orientation and shape of the particles. For instance, if the distribution of the typical particle is invariant under rotations, then the covariance matrix is proportional to the identity matrix. We develop a non-parametric test for such isotropy. A flexible Lévy-based particle model is proposed, which may be analysed using a generalized method of moments in which the volume tensors enter. The developed methods are used to study the cell organization in the human brain cortex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present paper, we describe new robust methods of estimating cell shape and orientation in 3D from sections. The descriptors of 3D cell shape and orientation are based on volume tensors which are used to construct an ellipsoid, the Miles ellipsoid, approximating the average cell shape and orientation in 3D. The estimators of volume tensors are based on observations in several optical planes through sampled cells. This type of geometric sampling design is known as the optical rotator. The statistical behaviour of the estimator of the Miles ellipsoid is studied under a flexible model for 3D cell shape and orientation. In a simulation study, the lengths of the axes of the Miles ellipsoid can be estimated with CVs of about 2% if 100 cells are sampled. Finally, we illustrate the use of the developed methods in an example, involving neurons in the medial prefrontal cortex of rat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using navigation systems in general orthopaedic surgery and, in particular, knee replacement is becoming more and more accepted. This paper describes the basic technological concepts of modern computer assisted surgical systems. It explains the variation in currently available systems and outlines research activities that will potentially influence future products. In general, each navigation system is defined by three components: (1) the therapeutic object is the anatomical structure that is operated on using the navigation system, (2) the virtual object represents an image of the therapeutic object, with radiological images or computer generated models potentially being used, and (3) last but not least, the navigator acquires the spatial position and orientation of instruments and anatomy thus providing the necessary data to replay surgical action in real-time on the navigation system's screen.