121 resultados para Proton halo

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Proton therapy is a high precision technique in cancer radiation therapy which allows irradiating the tumor with minimal damage to the surrounding healthy tissues. Pencil beam scanning is the most advanced dose distribution technique and it is based on a variable energy beam of a few millimeters FWHM which is moved to cover the target volume. Due to spurious effects of the accelerator, of dose distribution system and to the unavoidable scattering inside the patient's body, the pencil beam is surrounded by a halo that produces a peripheral dose. To assess this issue, nuclear emulsion films interleaved with tissue equivalent material were used for the first time to characterize the beam in the halo region and to experimentally evaluate the corresponding dose. The high-precision tracking performance of the emulsion films allowed studying the angular distribution of the protons in the halo. Measurements with this technique were performed on the clinical beam of the Gantry1 at the Paul Scherrer Institute. Proton tracks were identified in the emulsion films and the track density was studied at several depths. The corresponding dose was assessed by Monte Carlo simulations and the dose profile was obtained as a function of the distance from the center of the beam spot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Impaired function of the central gamma-aminobutyric acid (GABA) system, which provides the brain’s major inhibitory pathways, is thought to play an important role in the pathophysiology of anxiety disorders. The effect of acute psychological stress on the human GABA-ergic system is still unknown, however. The purpose of this study was to determine the effect of acute stress on prefrontal GABA levels. Method A recently developed noninvasive magnetic resonance spectroscopy method was used to measure changes in the GABA concentration of the prefrontal cortex in 10 healthy human subjects during a threat-of-shock condition and during a safe condition (two sessions on different days). The main outcome measure was the mean GABA concentration within a 3×3×2-cm3 voxel selected from the medial prefrontal cortex. Results Prefrontal GABA decreased by approximately 18% in the threat-of-shock condition relative to the safe condition. This reduction was specific to GABA, since the concentrations of N-acetyl-aspartate, choline-containing compounds, and glutamate/glutamine levels obtained in the same spectra did not change significantly. Conclusions This result appeared compatible with evidence from preclinical studies in rodents, which showed rapid presynaptic down-regulation of GABA-ergic neurotransmission in response to acute psychological stress. The molecular mechanism and functional significance of this reduced inhibitory effect of acute psychological stress in relation to impaired GABA-ergic function in anxiety disorders merit further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although magnetic resonance spectroscopy can be used as a unique tool to study molecular diffusion, it is rarely used to measure the diffusion properties of intramyocellular and extramyocellular lipids. Lipids have very low apparent diffusion coefficients (ADCs), which make these measurements difficult and necessitate strong diffusion gradients and long diffusion times. Consequence is that these measurements have inherently low signal-to-noise ratio and are prone to artifacts. The addition of physiological triggering and individual storage and processing of the spectra is seen to be a possible approach to maximize signal intensity and achieve high reproducibility of the experiments. Thus, the optimized measurement protocol was used to investigate the diffusion properties of lipids in human skeletal muscle in vivo. At a diffusion time of about 110 ms, intramyocellular lipids show a significantly lower ADC (2.0 × 10(-6) mm(2)/s, 95% confidence interval 1.10 × 10(-6) to 2.94 × 10(-6) mm(2)/s) than extramyocellular lipids (1.58 × 10(-5) mm(2)/s, 95% confidence interval 1.41 × 10(-5) to 1.75 × 10(-5) mm(2)/s). Because the chemical properties of both lipid pools can be assumed to be similar, the difference can only be attributed to restricted or severely hindered diffusion in the intramyocellular droplets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate a new isotropic 3D proton-density, turbo-spin-echo sequence with variable flip-angle distribution (PD-SPACE) sequence compared to an isotropic 3D true-fast-imaging with steady-state-precession (True-FISP) sequence and 2D standard MR sequences with regard to the new 3D magnetic resonance observation of cartilage repair tissue (MOCART) score.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance spectroscopy enables insight into the chemical composition of spinal cord tissue. However, spinal cord magnetic resonance spectroscopy has rarely been applied in clinical work due to technical challenges, including strong susceptibility changes in the region and the small cord diameter, which distort the lineshape and limit the attainable signal to noise ratio. Hence, extensive signal averaging is required, which increases the likelihood of static magnetic field changes caused by subject motion (respiration, swallowing), cord motion, and scanner-induced frequency drift. To avoid incoherent signal averaging, it would be ideal to perform frequency alignment of individual free induction decays before averaging. Unfortunately, this is not possible due to the low signal to noise ratio of the metabolite peaks. In this article, frequency alignment of individual free induction decays is demonstrated to improve spectral quality by using the high signal to noise ratio water peak from non-water-suppressed proton magnetic resonance spectroscopy via the metabolite cycling technique. Electrocardiography (ECG)-triggered point resolved spectroscopy (PRESS) localization was used for data acquisition with metabolite cycling or water suppression for comparison. A significant improvement in the signal to noise ratio and decrease of the Cramér Rao lower bounds of all metabolites is attained by using metabolite cycling together with frequency alignment, as compared to water-suppressed spectra, in 13 healthy volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for diphoton events with large missing transverse energy is presented. The data were collected with the ATLAS detector in proton-proton collisions at √s=7 TeV at the CERN Large Hadron Collider and correspond to an integrated luminosity of 3.1 pb⁻¹. No excess of such events is observed above the standard model background prediction. In the context of a specific model with one universal extra dimension with compactification radius R and gravity-induced decays, values of 1/R<729 GeV are excluded at 95% C. L., providing the most sensitive limit on this model to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of sqrt(s) = 7 TeV corresponding to an integrated luminosity of 38 inverse pb. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0.4 or R=0.6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pt > 20 GeV and pseudorapidities eta<4.5. The JES systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams. The JES uncertainty is less than 2.5% in the central calorimeter region (eta<0.8) for jets with 60 < pt < 800 GeV, and is maximally 14% for pt < 30 GeV in the most forward region 3.2proton-proton collisions in the same bunch crossing is less than 1.5% per additional collision for jets with pt > 50 GeV after a dedicated correction for this effect. The JES is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pt, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pt jets recoiling against a high-pt jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, providing an improved jet energy resolution and a reduced flavour dependence of the jet response. The JES systematic uncertainty determined from a combination of in situ techniques are consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pt jets.