7 resultados para Prosthetic knee unit

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of substitution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiography diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of our study was to correlate global T2 values of microfracture repair tissue (RT) with clinical outcome in the knee joint. METHODS: We assessed 24 patients treated with microfracture in the knee joint. Magnetic resonance (MR) examinations were performed on a 3T MR unit, T2 relaxation times were obtained with a multi-echo spin-echo technique. T2 maps were obtained using a pixel wise, mono-exponential non-negative least squares fit analysis. Slices covering the cartilage RT were selected and region of interest analysis was done. An individual T2 index was calculated with global mean T2 of the RT and global mean T2 of normal, hyaline cartilage. The Lysholm score and the International Knee Documentation Committee (IKDC) knee evaluation forms were used for the assessment of clinical outcome. Bivariate correlation analysis and a paired, two tailed t test were used for statistics. RESULTS: Global T2 values of the RT [mean 49.8ms, standards deviation (SD) 7.5] differed significantly (P<0.001) from global T2 values of normal, hyaline cartilage (mean 58.5ms, SD 7.0). The T2 index ranged from 61.3 to 101.5. We found the T2 index to correlate with outcome of the Lysholm score (r(s)=0.641, P<0.001) and the IKDC subjective knee evaluation form (r(s)=0.549, P=0.005), whereas there was no correlation with the IKDC knee form (r(s)=-0.284, P=0.179). CONCLUSION: These findings indicate that T2 mapping is sensitive to assess RT function and provides additional information to morphologic MRI in the monitoring of microfracture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Understanding of articular cartilage physiology, remodelling mechanisms, and evaluation of tissue engineering repair methods requires reference information regarding normal structural organization. Our goals were to examine the variation of cartilage cell and matrix morphology in different topographical areas of the adult human knee joint. METHODS: Osteochondral explants were acquired from seven distinct anatomical locations of the knee joints of deceased persons aged 20-40 years and prepared for analysis of cell, matrix and tissue morphology using confocal microscopy and unbiased stereological methods. Differences between locations were identified by statistical analysis. RESULTS: Medial femoral condyle cartilage had relatively high cell surface area per unit tissue volume in the superficial zone. In the transitional zone, meniscus-covered lateral tibia cartilage showed elevated chondrocyte densities compared to the rest of the knee while lateral femoral condyle cartilage exhibited particularly large chondrocytes. Statistical analyses indicated highly uniform morphology throughout the radial zone (lower 80% of cartilage thickness) in the knee, and strong similarities in cell and matrix morphologies among cartilage from the femoral condyles and also in the mediocentral tibial plateau. Throughout the adult human knee, the mean matrix volume per chondron was remarkably constant at approximately 224,000 microm(3), corresponding to approximately 4.6 x 10(6) chondrons per cm(3). CONCLUSIONS: The uniformity of matrix volume per chondron throughout the adult human knee suggests that cell-scale biophysical and metabolic constraints may place limitations on cartilage thickness, mechanical properties, and remodelling mechanisms. Data may also aid the evaluation of cartilage tissue engineering treatments in a site-specific manner. Results indicate that joint locations which perform similar biomechanical functions have similar cell and matrix morphologies; findings may therefore also provide clues to understanding conditions under which focal lesions leading to osteoarthritis may occur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of peri-prosthetic joint infection (PJI) of the ankle is not standardised. It is not clear whether an algorithm developed for hip and knee PJI can be used in the management of PJI of the ankle. We evaluated the outcome, at two or more years post-operatively, in 34 patients with PJI of the ankle, identified from a cohort of 511 patients who had undergone total ankle replacement. Their median age was 62.1 years (53.3 to 68.2), and 20 patients were women. Infection was exogenous in 28 (82.4%) and haematogenous in six (17.6%); 19 (55.9%) were acute infections and 15 (44.1%) chronic. Staphylococci were the cause of 24 infections (70.6%). Surgery with retention of one or both components was undertaken in 21 patients (61.8%), both components were replaced in ten (29.4%), and arthrodesis was undertaken in three (8.8%). An infection-free outcome with satisfactory function of the ankle was obtained in 23 patients (67.6%). The best rate of cure followed the exchange of both components (9/10, 90%). In the 21 patients in whom one or both components were retained, four had a relapse of the same infecting organism and three had an infection with another organism. Hence the rate of cure was 66.7% (14 of 21). In these 21 patients, we compared the treatment given to an algorithm developed for the treatment of PJI of the knee and hip. In 17 (80.9%) patients, treatment was not according to the algorithm. Most (11 of 17) had only one criterion against retention of one or both components. In all, ten of 11 patients with severe soft-tissue compromise as a single criterion had a relapse-free survival. We propose that the treatment concept for PJI of the ankle requires adaptation of the grading of quality of the soft tissues. Cite this article: Bone Joint J 2014;96-B:772-7.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteoarthritis of the knee is a major clinical burden. Recent decades have witnessed an improved understanding of knee physiology and kinematics, which has led to the introduction of a wide range of enhanced prosthetic implant designs for a variety of indications. However, the increase in the number of procedures performed annually has led to complications being encountered at higher rates than ever before, requiring the development of optimised therapeutic strategies. The future holds several promising options, primarily in the treatment of early osteoarthritis, biological therapy, surgical navigation and patient-specific implants. This review provides an insight into the current options of knee arthroplasty, with emphasis on available designs, and examines the complications that may be encountered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.