2 resultados para Pressure transducers.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The functional relevance of coronary collaterals in humans has yet to be fully explored. Several studies demonstrated a protective role of collaterals in patients with coronary artery disease. On the other hand, negative aspects of well-developed coronary collaterals have been reported, e.g. a higher rate of restenosis following coronary angioplasty, or a redistribution of blood via collaterals away from the myocardial area in need towards normally perfused areas (coronary steal). In the past, the coronary collateral circulation has been assessed only qualitatively, using visual angiographic or nuclear imaging methods. With the recent advent of intracoronary Doppler and pressure-transducers, quantitative assessment of functional parameters of the coronary circulation has become feasible. This article reviews ongoing research in the field of coronary collaterals in humans, concerning their exact determination, the positive and negative aspects of their structure as well as their functional aspects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the maximum urethral closure pressure (MUCP) measures with two different techniques: water perfused catheter and microtip transducer catheters with respect to reproducibility and comparability for urethral pressure measurements. Eighteen women with stress urinary incontinence had repeat static urethral pressure profilometry on a different day using a dual microtip transducer and water perfused catheter (Brown and Wickham). The investigators were blinded to the results of the other. The microtip measurements were taken in the 45 degrees upright sitting position with the patient at rest at a bladder capacity of 250 ml using an 8 Fr Gaeltec(R) double microtip transducer withdrawn at 1 mm/s, and the transducer was orientated in the three o'clock position. Three different measures were taken for each patient. Three water perfusion measurements were performed with the patient at rest in the 45 degrees upright position at a bladder capacity of 250 ml using an 8 Fr BARD dual lumen catheter withdrawn at 1 mm/s. The mean water perfusion MUCP measure was 26.1 cm H(2)0, significantly lower than the mean microtip measure of 35.7 cm H(2)0. The correlation coefficient comparing each water perfusion measurement with the other water perfusion measures in the same patient was excellent, at 0.95 (p = 0.01). Correlation coefficient comparing each microtip measure with the other microtip measure in the same patient was also good, ranging from 0.70 to 0.80. This study confirms that both water perfusion catheters and microtip transducers have excellent or very good reproducibility with an acceptable intraindividual variation for both methods.