12 resultados para PowerPlex (R) 16 System
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Group B Streptococcus (GBS) causes invasive infections in neonates, older adults and patients with comorbidities. β-hemolysin/cytolysin is an important GBS virulence factor. It is encoded by the cyl operon and confers GBS hemolytic activity. Isolates displaying hyperpigmentation are typically hyperhemolytic. Comparison of clonally identical isolates displaying different levels of pigmentation has shown transcriptional dysregulation due to mutations in components of the control of the virulence S/R (CovS/R) regulatory system. In addition, hyperpigmented isolates show decreased CAMP factor and decreased capsule thickness. In analogy to findings in group A Streptococcus, a pivotal role of CovS/R has been proposed in the host-pathogen interaction of invasive GBS infection. However, corresponding investigations on multiple clinical GBS isolates have not been performed. We prospectively collected hyperpigmented isolates found in a diagnostic laboratory and performed phenotypic, molecular and transcriptional analyses. In the period from 2008 to 2012, we found 10 isolates obtained from 10 patients. The isolates reflected both invasive pathogens and colonizers. In three cases, clonally identical but phenotypically different variants were also found. Hence, the analyses included 13 isolates. No capsular serotype was found to be significantly more frequent. Bacterial pigments were analyzed via spectrophotometry and for their hemolytic activity. Data obtained for typical absorbance spectra peaks correlated significantly with hemolytic activity. Molecular analysis of the cyl operon showed that it was conserved in all isolates. The covR sequence displayed mutations in five isolates; in one isolate, the CovR binding site to cylX was abrogated. Our results on clinical isolates support previous findings on CovR-deficient isogenic mutants, but suggest that - at least in some clinical isolates - for β-hemolysin/cytolysin and CAMP factor production, other molecular pathways may be involved.
Resumo:
Low rates of nest acceptance by laying hens are a major problem in commercial poultry farming operations with aviary systems, leading to costly manual collection and cleaning of mislaid eggs. To gain knowledge about factors affecting nest use, laying hens' preferences for different nest locations were tested. Nests are normally installed at one of two sites: against a wall of the hen house or integrated into one tier of the aviary rack The preferences of laying hens for different nest sites have never been examined under commercial conditions. The aim of this study is to investigate whether behavioural differences can be detected between the different nest sites. The study consists of two consecutive trials involving 5027 Lohmann Selected Leghorn hens (LSL) and 601 layer hybrids selected for extensive housing conditions (EXT). The hens were randomly assigned to eight compartments per trial in groups of 355-360 LSL or 300 EXT in a laying hen house. Four compartments were equipped with a Volito Voletage (R) aviary system (VV), and four were equipped with a Rihs Bolegell (R) aviary system (RB), both of which contained either integrated or wall-placed nests when the experiments started. A strongly balanced crossover design with four periods was used. At 36, 44 and 52 weeks of age, the nest site in four out of the eight compartments was switched. Before each change, the fronts of half of the nests were videotaped during the light period, and the behaviour throughout the main laying period was analysed. Furthermore, the numbers of nest eggs and mislaid eggs in each compartment were recorded every day. No differences in the number of mislaid eggs between the two nest sites could be detected, except at the age of 20/21 weeks when hens in VV aviaries mislaid more eggs when nests were integrated (P = 0.0012). More hens stood simultaneously in front of the integrated nests than in front of wall-placed nests (P = 0.015). Activity of the laying hens increased (P = 0.0073), and stationary behavioural patterns declined (P = 0.0093), when the nests were placed by the wall. Hens inspected integrated nests for a longer duration than wall-placed nests, but wall-placed nests were visited more frequently. In addition to the nest site, the width of the platform in front of the nest influenced laying hen behaviour. Compared with narrower platforms, balance movements decreased on wider ones. Additionally, the platform design had to be taken into account as well, given that hens could not stand or walk as securely on wooden slats as on a grid floor. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND Current guidelines give recommendations for preferred combination antiretroviral therapy (cART). We investigated factors influencing the choice of initial cART in clinical practice and its outcome. METHODS We analyzed treatment-naive adults with human immunodeficiency virus (HIV) infection participating in the Swiss HIV Cohort Study and starting cART from January 1, 2005, through December 31, 2009. The primary end point was the choice of the initial antiretroviral regimen. Secondary end points were virologic suppression, the increase in CD4 cell counts from baseline, and treatment modification within 12 months after starting treatment. RESULTS A total of 1957 patients were analyzed. Tenofovir-emtricitabine (TDF-FTC)-efavirenz was the most frequently prescribed cART (29.9%), followed by TDF-FTC-lopinavir/r (16.9%), TDF-FTC-atazanavir/r (12.9%), zidovudine-lamivudine (ZDV-3TC)-lopinavir/r (12.8%), and abacavir/lamivudine (ABC-3TC)-efavirenz (5.7%). Differences in prescription were noted among different Swiss HIV Cohort Study sites (P < .001). In multivariate analysis, compared with TDF-FTC-efavirenz, starting TDF-FTC-lopinavir/r was associated with prior AIDS (relative risk ratio, 2.78; 95% CI, 1.78-4.35), HIV-RNA greater than 100 000 copies/mL (1.53; 1.07-2.18), and CD4 greater than 350 cells/μL (1.67; 1.04-2.70); TDF-FTC-atazanavir/r with a depressive disorder (1.77; 1.04-3.01), HIV-RNA greater than 100 000 copies/mL (1.54; 1.05-2.25), and an opiate substitution program (2.76; 1.09-7.00); and ZDV-3TC-lopinavir/r with female sex (3.89; 2.39-6.31) and CD4 cell counts greater than 350 cells/μL (4.50; 2.58-7.86). At 12 months, 1715 patients (87.6%) achieved viral load less than 50 copies/mL and CD4 cell counts increased by a median (interquartile range) of 173 (89-269) cells/μL. Virologic suppression was more likely with TDF-FTC-efavirenz, and CD4 increase was higher with ZDV-3TC-lopinavir/r. No differences in outcome were observed among Swiss HIV Cohort Study sites. CONCLUSIONS Large differences in prescription but not in outcome were observed among study sites. A trend toward individualized cART was noted suggesting that initial cART is significantly influenced by physician's preference and patient characteristics. Our study highlights the need for evidence-based data for determining the best initial regimen for different HIV-infected persons.
Resumo:
OBJECTIVES:: This study was designed to apply the rapid Elecsys(R) S100 immunoassay for real-time measurement of S100 protein serum levels indicating acute brain damage in patients undergoing carotid artery stenting (CAS) or endarterectomy (CEA). DESIGN AND METHODS:: Data of 14 CAS patients were compared to those of 43 CEA and 14 control patients undergoing coronary angiography (CA). S100 serum levels were measured by the full-automatic Elecsys(R) S100 immunoassay and compared to those obtained by the well-established LIA-mat(R) S100 system. RESULTS:: In contrast to CAS and CA patients, median S100 serum levels of CEA patients significantly increased to 0.24 ng/mL before declamping, but subsequently returned to baseline. Three CEA patients with neurological deficits showed sustained elevated S100 levels 6 h after extubation. Absolute S100 values were not significantly different between the two methods. Bland-Altman plot analyses displayed a good agreement, mostly indicating slightly smaller values applying the Elecsys(R) S100 system. CONCLUSIONS:: The Elecsys(R) S100 system appears to be suitable for rapid real-time detection of neurological deficits in patients undergoing CAS and CEA. Persistent elevations of Elecsys(R) S100 levels during CEA were associated with prolonged neurological disorders, whereas transient increases seem to represent impaired blood-brain barrier integrity without neurological deficits.
Resumo:
Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.
Resumo:
Objective. The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Methods. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. Results. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7mmHgand-0.9+/- 0.5mmHg, respectively), withameanpulsepressureof3.4mmHg.ThedifferencebetweenthemeanCVPandCVPatend-diastoleduringexpirationwas0.58+/- 0.81 mmHg. Conclusions. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Resumo:
OBJECTIVES: To assess perioperative outcomes and blood pressure (BP) responses to an implantable carotid sinus baroreflex activating system being investigated for the treatment of resistant hypertension. METHODS: We report on the first seventeen patients enrolled in a multicenter study. Bilateral perivascular carotid sinus electrodes (CSL) and a pulse generator (IPG) are permanently implanted. Optimal placement of the CSL is determined by intraoperative BP responses to test activations. Acute BP responses were tested postoperatively and during the first four months of follow-up. RESULTS: Prior to implant, BP was 189.6+/-27.5/110.7+/-15.3 mmHg despite stable therapy (5.2+/-1.8 antihypertensive drugs). The mean procedure time was 202+/-43 minutes. No perioperative strokes or deaths occurred. System tests performed 1 or up to 3 days postoperatively resulted in significant (all p < or = 0.0001) mean maximum reduction, with standard deviations and 95% confidence limits for systolic BP, diastolic BP and heart rate of 28+/-22 (17, 39) mmHg, 16+/-11 (10, 22) mmHg and 8+/-4 (6, 11) BPM, respectively. Repeated testing during 3 months of therapeutic electrical activation demonstrated a durable response. CONCLUSIONS: These preliminary data suggest an acceptable safety of the procedure with a low rate of adverse events and support further clinical development of baroreflex activation as a new concept to treat resistant hypertension.
Resumo:
This work addresses the evolution of an artificial neural network (ANN) to assist in the problem of indoor robotic localization. We investigate the design and building of an autonomous localization system based on information gathered from wireless networks (WN). The article focuses on the evolved ANN, which provides the position of a robot in a space, as in a Cartesian coordinate system, corroborating with the evolutionary robotic research area and showing its practical viability. The proposed system was tested in several experiments, evaluating not only the impact of different evolutionary computation parameters but also the role of the transfer functions on the evolution of the ANN. Results show that slight variations in the parameters lead to significant differences on the evolution process and, therefore, in the accuracy of the robot position.
Resumo:
We analyzed more than 200 OSIRIS NAC images with a pixel scale of 0.9-2.4 m/pixel of comet 67P/Churyumov-Gerasimenko (67P) that have been acquired from onboard the Rosetta spacecraft in August and September 2014 using stereo-photogrammetric methods (SPG). We derived improved spacecraft position and pointing data for the OSIRIS images and a high-resolution shape model that consists of about 16 million facets (2 m horizontal sampling) and a typical vertical accuracy at the decimeter scale. From this model, we derive a volume for the northern hemisphere of 9.35 km(3) +/- 0.1 km(3). With the assumption of a homogeneous density distribution and taking into account the current uncertainty of the position of the comet's center-of-mass, we extrapolated this value to an overall volume of 18.7 km(3) +/- 1.2 km(3), and, with a current best estimate of 1.0 X 10(13) kg for the mass, we derive a bulk density of 535 kg/m(3) +/- 35 kg/m(3). Furthermore, we used SPG methods to analyze the rotational elements of 67P. The rotational period for August and September 2014 was determined to be 12.4041 +/- 0.0004 h. For the orientation of the rotational axis (z-axis of the body-fixed reference frame) we derived a precession model with a half-cone angle of 0.14 degrees, a cone center position at 69.54 degrees/64.11 degrees (RA/Dec J2000 equatorial coordinates), and a precession period of 10.7 days. For the definition of zero longitude (x-axis orientation), we finally selected the boulder-like Cheops feature on the big lobe of 67P and fixed its spherical coordinates to 142.35 degrees right-hand-rule eastern longitude and -0.28 degrees latitude. This completes the definition of the new Cheops reference frame for 67P. Finally, we defined cartographic mapping standards for common use and combined analyses of scientific results that have been obtained not only within the OSIRIS team, but also within other groups of the Rosetta mission.
Resumo:
There have been many studies pertaining to the management of herpetic meningoencephalitis (HME), but the majority of them have focussed on virologically unconfirmed cases or included only small sample sizes. We have conducted a multicentre study aimed at providing management strategies for HME. Overall, 501 adult patients with PCR-proven HME were included retrospectively from 35 referral centres in 10 countries; 496 patients were found to be eligible for the analysis. Cerebrospinal fluid (CSF) analysis using a PCR assay yielded herpes simplex virus (HSV)-1 DNA in 351 patients (70.8%), HSV-2 DNA in 83 patients (16.7%) and undefined HSV DNA type in 62 patients (12.5%). A total of 379 patients (76.4%) had at least one of the specified characteristics of encephalitis, and we placed these patients into the encephalitis presentation group. The remaining 117 patients (23.6%) had none of these findings, and these patients were placed in the nonencephalitis presentation group. Abnormalities suggestive of encephalitis were detected in magnetic resonance imaging (MRI) in 83.9% of the patients and in electroencephalography (EEG) in 91.0% of patients in the encephalitis presentation group. In the nonencephalitis presentation group, MRI and EEG data were suggestive of encephalitis in 33.3 and 61.9% of patients, respectively. However, the concomitant use of MRI and EEG indicated encephalitis in 96.3 and 87.5% of the cases with and without encephalitic clinical presentation, respectively. Considering the subtle nature of HME, CSF HSV PCR, EEG and MRI data should be collected for all patients with a central nervous system infection.