16 resultados para Piezoelectric coefficient

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two recent scanning probe techniques were applied to investigate the bipolar twin state of 4-iodo-4′-nitrobiphenyl (INBP) crystals. Solution grown crystals of INBP show typically a morphology which does not express that of a mono-domain polar structure (Fdd2, mm2). From previous X-ray diffraction a twinning volume ratio of [similar]70 : 30 is now explained by two unipolar domains (Flack parameter: 0.075(29)) of opposite orientation of the molecular dipoles, joined by a transition zone showing a width of [similar]140 μm. Scanning pyroelectric microscopy (SPEM) demonstrates a continuous transition of the polarization P from +P into −P across the zone. Application of piezoelectric force microscopy (PFM) confirms unipolar alignment of INBP molecules down to a resolution of [similar]20 nm. A previously proposed real structure for INBP crystals built from lamellae with antiparallel alignment is thus rejected. Anomalous X-ray scattering was used to determine the absolute molecular orientation in the two domains. End faces of the polar axis 2 are thus made up by NO2 groups. Using a previously determined negative pyroelectric coefficient pc leads to a confirmation also by a SPEM analysis. Calculated values for functional group interactions (DA), (AA), (DD) and the stochastic theory of polarity formation allow us to predict that NO2 groups should terminate corresponding faces. Following the present analysis, INBP may represent a first example undergoing dipole reversal upon growth to end up in a bipolar state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel magnetic resonance imaging sequences have and still continue to play an increasing role in neuroimaging and neuroscience. Among these techniques, diffusion-weighted imaging (DWI) has revolutionized the diagnosis and management of diseases such as stroke, neoplastic disease and inflammation. However, the effects of aging on diffusion are yet to be determined. To establish reference values for future experimental mouse studies we tested the hypothesis that absolute apparent diffusion coefficients (ADC) of the normal brain change with age. A total of 41 healthy mice were examined by T2-weighted imaging and DWI. For each animal ADC frequency histograms (i) of the whole brain were calculated on a voxel-by-voxel basis and region-of-interest (ROI) measurements (ii) performed and related to the animals' age. The mean entire brain ADC of mice <3 months was 0.715(+/-0.016) x 10(-3) mm2/s, no significant difference to mice aged 4 to 5 months (0.736(+/-0.040) x 10(-3) mm2/s) or animals older than 9 months 0.736(+/-0.020) x 10(-3) mm2/s. Mean whole brain ADCs showed a trend towards lower values with aging but both methods (i + ii) did not reveal a significant correlation with age. ROI measurements in predefined areas: 0.723(+/-0.057) x 10(-3) mm2/s in the parietal lobe, 0.659(+/-0.037) x 10(-3) mm2/s in the striatum and 0.679(+/-0.056) x 10(-3) mm2/s in the temporal lobe. With advancing age, we observed minimal diffusion changes in the whole mouse brain as well as in three ROIs by determination of ADCs. According to our data ADCs remain nearly constant during the aging process of the brain with a small but statistically non-significant trend towards a decreased diffusion in older animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Diffusion-weighted MRI is sensitive to molecular motion and has been applied to the diagnosis of stroke. Our intention was to investigate its usefulness in patients with brain tumor and, in particular, in the perilesional edema. METHODS: We performed MRI of the brain, including diffusion-weighted imaging and mapping of the apparent diffusion coefficient (ADC), in 16 patients with brain tumors (glioblastomas, low-grade gliomas and metastases). ADC values were determined by the use of regions of interest positioned in areas of high signal intensities as seen on T2-weighted images and ADC maps. Measurements were taken in the tumor itself, in the area of perilesional edema and in the healthy contralateral brain. RESULTS: ADC mapping showed higher values of peritumoral edema in patients with glioblastoma (1.75 x 10(-3)mm(2)/s) and metastatic lesions (1.61 x 10(-3)mm(2)/s) compared with those who had low-grade glioma (1.40 x10(-3)mm(2)/s). The higher ADC values in the peritumoral zone were associated with lower ADC values in the tumor itself. CONCLUSIONS: The higher ADC values in the more malignant tumors probably reflect vasogenic edema, thereby allowing their differentiation from other lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine how the ADC value of parotid glands is influenced by the choice of b-values. MATERIALS AND METHODS: In eight healthy volunteers, diffusion-weighted echo-planar imaging (DW-EPI) was performed on a 1.5 T system, with b-values (in seconds/mm2) of 0, 50, 100, 150, 200, 250, 300, 500, 750, and 1000. ADC values were calculated by two alternative methods (exponential vs. logarithmic fit) from five different sets of b-values: (A) all b-values; (B) b=0, 50, and 100; (C) b=0 and 750; (D) b=0, 500, and 1000; and (E) b=500, 750, and 1000. RESULTS: The mean ADC values for the different settings were (in 10(-3) mm2/second, exponential fit): (A) 0.732+/-0.019, (B) 2.074+/-0.084, (C) 0.947+/-0.020, (D) 0.890+/-0.023, and (E) 0.581+/-0.021. ADC values were significantly (P <0.001) different for all pairwise comparisons of settings (A-E) of b-values, except for A vs. D (P=0.172) and C vs. D (P=0.380). The ADC(B) was significantly higher than ADC(C) or ADC(D), which was significantly higher than ADC(E). ADC values from exponential vs. logarithmic fit (P=0.542), as well as left vs. right parotid gland (P=0.962), were indistinguishable. CONCLUSION: The ADC values calculated from low b-value settings were significantly higher than those calculated from high b-value settings. These results suggest that not only true diffusion but also perfusion and saliva flow may contribute to the ADC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Software metrics offer us the promise of distilling useful information from vast amounts of software in order to track development progress, to gain insights into the nature of the software, and to identify potential problems. Unfortunately, however, many software metrics exhibit highly skewed, non-Gaussian distributions. As a consequence, usual ways of interpreting these metrics --- for example, in terms of "average" values --- can be highly misleading. Many metrics, it turns out, are distributed like wealth --- with high concentrations of values in selected locations. We propose to analyze software metrics using the Gini coefficient, a higher-order statistic widely used in economics to study the distribution of wealth. Our approach allows us not only to observe changes in software systems efficiently, but also to assess project risks and monitor the development process itself. We apply the Gini coefficient to numerous metrics over a range of software projects, and we show that many metrics not only display remarkably high Gini values, but that these values are remarkably consistent as a project evolves over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Extended grafting procedures in atrophic ridges are invasive and time-consuming and increase cost and patient morbidity. Therefore, ridge-splitting techniques have been suggested to enlarge alveolar crests. The aim of this cohort study was to report techniques and radiographic outcomes of implants placed simultaneously with a piezoelectric alveolar ridge-splitting technique (RST). Peri-implant bone-level changes (ΔIBL) of implants placed with (study group, SG) or without RST (control group, CG) were compared. MATERIALS AND METHODS Two cohorts (seven patients in each) were matched regarding implant type, position, and number; superstructure type; age; and gender and received 17 implants each. Crestal implant bone level (IBL) was measured at surgery (T0), loading (T1), and 1 year (T2) and 2 years after loading (T3). For all implants, ΔIBL values were determined from radiographs. Differences in ΔIBL between SG and CG were analyzed statistically (Mann-Whitney U test). Bone width was assessed intraoperatively, and vertical bone mapping was performed at T0, T1, and T3. RESULTS After a mean observation period of 27.4 months after surgery, the implant survival rate was 100%. Mean ΔIBL was -1.68 ± 0.90 mm for SG and -1.04 ± 0.78 mm for CG (P = .022). Increased ΔIBL in SG versus CG occurred mainly until T2. Between T2 and T3, ΔIBL was limited (-0.11 ± 1.20 mm for SG and -0.05 ± 0.16 mm for CG; P = .546). Median bone width increased intraoperatively by 4.7 mm. CONCLUSIONS Within the limitations of this study, it can be suggested that RST is a well-functioning one-stage alternative to extended grafting procedures if the ridge shows adequate height. ΔIBL values indicated that implants with RST may fulfill accepted implant success criteria. However, during healing and the first year of loading, increased IBL alterations must be anticipated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We calculate the momentum diffusion coefficient for heavy quarks in SU(3) gluon plasma at temperatures 1-2 times the deconfinement temperature. The momentum diffusion coefficient is extracted from a Monte Carlo calculation of the correlation function of color electric fields, in the leading order of expansion in heavy quark mass. Systematics of the calculation are examined, and compared with perturbtion theory and other estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analytic continuation needed for the extraction of transport coefficients necessitates in principle a continuous function of the Euclidean time variable. We report on progress towards achieving the continuum limit for 2-point correlator measurements in thermal SU(3) gauge theory, with specific attention paid to scale setting. In particular, we improve upon the determination of the critical lattice coupling and the critical temperature of pure SU(3) gauge theory, estimating r0Tc ≃ 0.7470(7) after a continuum extrapolation. As an application the determination of the heavy quark momentum diffusion coefficient from a correlator of colour-electric fields attached to a Polyakov loop is discussed.