5 resultados para Peritectic reaction temperature
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Real-time quantitative polymerase chain reaction (qPCR) depends on precise temperature control of the sample during cycling. In the current study, we investigated how temperature variation in plate-based qPCR instruments influences qPCR results. Temperature variation was measured by amplicon melting analysis as a convenient means to assess well-to-well differences. Multiple technical replicates of several SYBR Green I-based qPCR assays allowed correlation of relative well temperature to quantification cycle. We found that inadequate template denaturation results in an inverse correlation and requires increasing the denaturation temperature, adding a DNA destabilizing agent, or pretreating with a restriction enzyme. In contrast, inadequate primer annealing results in a direct correlation and requires lowering the annealing temperature. Significant correlations were found in 18 of 25 assays. The critical nature of temperature-dependent effects was shown in a blinded study of 29 patients for the diagnosis of Prader-Willy and Angelman syndromes, where eight diagnoses were incorrect unless temperature-dependent effects were controlled. A method to detect temperature-dependent effects by pairwise comparisons of replicates in routine experiments is presented and applied. Systematic temperature errors in qPCR instruments can be recognized and their effects eliminated when high precision is required in quantitative genetic diagnostics and critical complementary DNA analyses.
Resumo:
BACKGROUND The treatment of proximal humerus fractures in patients with poor bone quality remains a challenge in trauma surgery. Augmentation with polymethylmethacrylate (PMMA) cement is a possible method to strengthen the implant anchorage in osteoporotic bone and to avoid loss of reduction and reduce the cut-out risk. The polymerisation of PMMA during cement setting leads, however, to an exothermic reaction and the development of supraphysiological temperatures may harm the bone and cartilage. This study addresses the issue of heat development during augmentation of subchondrally placed proximal humerus plate screws with PMMA and the possible risk of bone and cartilage necrosis and apoptosis. METHODS Seven fresh frozen humeri from geriatric female donors were instrumented with the proximal humerus interlocking system (PHILOS) plate and placed in a 37°C water bath. Thereafter, four proximal perforated screws were augmented with 0.5 ml PMMA each. During augmentation, the temperatures in the subchondral bone and on the articular surface were recorded with K-type thermocouples. The measured temperatures were compared to threshold values for necrosis and apoptosis of bone and cartilage reported in the literature. RESULTS The heat development was highest around the augmented tips of the perforated screws and diminished with growing distance from the cement cloud. The highest temperature recorded in the subchondral bone reached 43.5°C and the longest exposure time above 42°C was 86s. The highest temperature measured on the articular surface amounted to 38.6°C and the longest exposure time above 38°C was 5 min and 32s. CONCLUSION The study shows that augmentation of the proximal screws of the PHILOS plate with PMMA leads to a locally limited development of supraphysiological temperatures in the cement cloud and closely around it. The critical threshold values for necrosis and apoptosis of cartilage and subchondral bone reported in the literature, however, are not reached. In order to avoid cement extravasation, special care should be taken in detecting perforations or intra-articular cracks in the humeral head.
Resumo:
Senescent higher plants degrade their chlorophylls (Chls) to polar colorless tetrapyrrolic Chl catabolites, which accumulate in the vacuoles. In extracts from degreened leaves of the tree Cercidiphyllum japonicum an unpolar catabolite of this type was discovered. This tetrapyrrole was named Cj-NCC-2 and was found to be identical with the product of a stereoselective nonenzymatic isomerization of a “fluorescent” Chl catabolite. This (bio-mimetic) formation of the “nonfluorescent” catabolite Cj-NCC-2 took place readily at ambient temperature and at pH 4.9 in aqueous solution. The indicated nonenzymatic process is able to account for a crucial step during Chl breakdown in senescent higher plants. Once delivered to the acidic vacuoles, the fluorescent Chl catabolites are due to undergo a rapid, stereoselective isomerization to the ubiquitous nonfluorescent catabolites. The degradation of the Chl macrocycle is thus indicated to rely on just two known enzymes, one of which is senescence specific and cuts open the chlorin macroring. The two enzymes supply the fluorescent Chl catabolites, which are “programmed” to isomerize further rapidly in an acidic medium, as shown here. Indeed, only small amounts of the latter are temporarily observable during senescence in higher plants.
Resumo:
Three groups of Atlantic salmon were kept at a constant temperature of 4, 10 and 14 °C. The adipose fins were removed; six fish/group were sampled at 11 subsequent time points post-clipping. Samples were prepared for histopathological examination to study the course of re-epithelization. A score sheet was developed to assess the regeneration of epidermal and dermal cell types. Wounds were covered by a thin epidermal layer between 4 and 6 h post-clipping at 10 and 14 °C. In contrast, wound closure was completed between 6 and 12 h in fish held at a constant temperature of 4 °C. By 18 h post-clipping, superficial cells, cuboidal cells, prismatic basal cells and mucous cells were discernible in all temperature groups, rapidly progressing towards normal epidermal structure and thickness. Within the observation period, only minor regeneration was found in the dermal layers. A positive correlation between water temperature and healing rates was established for the epidermis. The rapid wound closure rate, epidermal normalization and the absence of inflammatory reaction signs suggest that adipose fin clipping under anaesthesia constitutes a minimally invasive method that may be used to mark large numbers of salmon presmolts without compromising fish welfare.
Resumo:
The Zr-in-rutile geothermometer is potentially a widely applicable tool to estimate peak metamorphic temperatures in rocks from diverse geological settings. In order to evaluate its usefulness and reliability to record and preserve high temperatures in granulite facies rocks, rutile from UHT rocks was investigated to assess different mechanisms of Zr (re-)distribution following cooling from high temperature. Granulite facies paragneisses from the lowermost part of the Ivrea Zone, Italy, incorporated as thin sheets into the extensive basaltic body of the Mafic Complex were selected for this study. The results show that Zr-in-rutile thermometry, if properly applied, is well suited to identify and study UHT terranes as it preserves a record of temperatures up to 1190 °C, although the thermometer is susceptible to partial post-peak metamorphic resetting by Zr diffusion. Texturally homogeneous rutile grains preserve Zr concentrations corresponding to temperatures of prograde rutile growth. Diverse rutile textures and relationships between some rutile host grains and included or adjacent Zr-bearing phases bear testimony to varying mechanisms of partial redistribution and resetting of Zr in rutile during cooling and link Zr-in-rutile temperatures to different steps of the metamorphic evolution. Rutile grains that equilibrated their Zr concentrations at temperatures above 1070 °C (i.e. 1.1 wt% Zr) could not retain all Zr in the rutile structure during cooling and exsolved baddeleyite (ZrO2). By subsequent reaction of baddeleyite exsolution lamellae with SiO2, zircon needles formed before the system finally closed at 650–700 °C without significant net loss of Zr from the whole host rutile grain. By reintegration of zircon exsolution needles, peak metamorphic temperatures of up to 1190 °C are derived for the studied rocks, which demonstrates the suitability of this solution thermometer to record UHT conditions and also confirms the extraordinary geological setting of the lowermost part of the Ivrea Zone.