Resumo:
The international orthopaedic community aims to achieve the best possible outcome for patient care by constantly modifying surgical techniques and expanding the surgeon's knowledge. These efforts require proper reflection within a setting that necessitates a higher quality standard for global orthopaedic publication. Furthermore, these techniques demand that surgeons acquire information at a rapid rate while enforcing higher standards in research performance. An international consensus exists on how to perform research and what rules should be considered when publishing a scientific paper. Despite this global agreement, in today's "Cross Check Era", too many authors do not give attention to the current standards of systematic research. Thus, the purpose of this paper is to describe these performance standards, the available choices for orthopaedic surgeons and the current learning curve for seasoned teams of researchers and orthopaedic surgeons with more than three decades of experience. These lead to provide an accessible overview of all important aspects of the topics that will significantly influence the research development as we arrive at an important globalisation era in orthopaedics and trauma-related research.
Resumo:
Introduction To meet the quality standards for high-stakes OSCEs, it is necessary to ensure high quality standardized performance of the SPs involved.[1] One of the ways this can be assured is through the assessment of the quality of SPs` performance in training and during the assessment. There is some literature concerning validated instruments that have been used to assess SP performance in formative contexts but very little related to high stakes contexts.[2], [3], [4]. Content and structure During this workshop different approaches to quality control for SPs` performance, developed in medicine, pharmacy and nursing OSCEs, will be introduced. Participants will have the opportunity to use these approaches in simulated interactions. Advantages and disadvantages of these approaches will be discussed. Anticipated outcomes By the end of this session, participants will be able to discuss the rationale for quality control of SPs` performance in high stakes OSCEs, outline key factors in creating strategies for quality control, identify various strategies for assuring quality control, and reflect on applications to their own practice. Who should attend The workshop is designed for those interested in quality assurance of SP performance in high stakes OSCEs. Level All levels are welcome. References Adamo G. 2003. Simulated and standardized patients in OSCEs: achievements and challenges:1992-2003. Med Teach. 25(3), 262- 270. Wind LA, Van Dalen J, Muijtjens AM, Rethans JJ. Assessing simulated patients in an educational setting: the MaSP (Maastricht Assessment of Simulated Patients). Med Educ 2004, 38(1):39-44. Bouter S, van Weel-Baumgarten E, Bolhuis S. Construction and validation of the Nijmegen Evaluation of the Simulated Patient (NESP): Assessing Simulated Patients' ability to role-play and provide feedback to students. Acad Med: Journal of the Association of American Medical Colleges 2012. May W, Fisher D, Souder D: Development of an instrument to measure the quality of standardized/simulated patient verbal feedback. Med Educ 2012, 2(1).
Resumo:
Allergist/clinical immunologist maintenance of certification and training program reaccreditation are mandatory in some countries. The World Allergy Organization conducted surveys in 2009 and 2011 to assess where such programs were available and to promote the establishment of such programs on a global level. This was done with the presumption that after such an "inventory," World Allergy Organization could offer guidance to its Member Societies on the promotion of such programs to assure the highest standards of practice in the field of allergy and clinical immunology. This review draws on the experience of countries where successful programs are in place and makes recommendations for those wishing to implement such programs for the specialty.
Resumo:
Carnitine is an amino acid derivative that plays a key role in energy metabolism. Endogenous carnitine is found in its free form or esterified with acyl groups of several chain lengths. Quantification of carnitine and acylcarnitines is of particular interest for screening for research and metabolic disorders. We developed a method with online solid-phase extraction coupled to high-performance liquid chromatography and tandem mass spectrometry to quantify carnitine and three acylcarnitines with different polarity (acetylcarnitine, octanoylcarnitine, and palmitoylcarnitine). Plasma samples were deproteinized with methanol, loaded on a cation exchange trapping column and separated on a reversed-phase C8 column using heptafluorobutyric acid as an ion-pairing reagent. Considering the endogenous nature of the analytes, we quantified with the standard addition method and with external deuterated standards. Solid-phase extraction and separation were achieved within 8 min. Recoveries of carnitine and acylcarnitines were between 98 and 105 %. Both quantification methods were equally accurate (all values within 84 to 116 % of target concentrations) and precise (day-to-day variation of less than 18 %) for all carnitine species and concentrations analyzed. The method was used successfully for determination of carnitine and acylcarnitines in different human samples. In conclusion, we present a method for simultaneous quantification of carnitine and acylcarnitines with a rapid sample work-up. This approach requires small sample volumes and a short analysis time, and it can be applied for the determination of other acylcarnitines than the acylcarnitines tested. The method is useful for applications in research and clinical routine.
Resumo:
BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.
Resumo:
BACKGROUND We describe the setup of a neonatal quality improvement tool and list which peer-reviewed requirements it fulfils and which it does not. We report on the so-far observed effects, how the units can identify quality improvement potential, and how they can measure the effect of changes made to improve quality. METHODS Application of a prospective longitudinal national cohort data collection that uses algorithms to ensure high data quality (i.e. checks for completeness, plausibility and reliability), and to perform data imaging (Plsek's p-charts and standardized mortality or morbidity ratio SMR charts). The collected data allows monitoring a study collective of very low birth-weight infants born from 2009 to 2011 by applying a quality cycle following the steps 'guideline - perform - falsify - reform'. RESULTS 2025 VLBW live-births from 2009 to 2011 representing 96.1% of all VLBW live-births in Switzerland display a similar mortality rate but better morbidity rates when compared to other networks. Data quality in general is high but subject to improvement in some units. Seven measurements display quality improvement potential in individual units. The methods used fulfil several international recommendations. CONCLUSIONS The Quality Cycle of the Swiss Neonatal Network is a helpful instrument to monitor and gradually help improve the quality of care in a region with high quality standards and low statistical discrimination capacity.
Resumo:
Sediments can act as long-term sinks for environmental pollutants. Within the past decades, dioxin-like compounds (DLCs) such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs) have attracted significant attention in the scientific community. To investigate the time- and concentration-dependent uptake of DLCs and PAHs in rainbow trout (Oncorhynchus mykiss) and their associated toxicological effects, we conducted exposure experiments using suspensions of three field-collected sediments from the rivers Rhine and Elbe, which were chosen to represent different contamination levels. Five serial dilutions of contaminated sediments were tested; these originated from the Prossen and Zollelbe sampling sites (both in the river Elbe, Germany) and from Ehrenbreitstein (Rhine, Germany), with lower levels of contamination. Fish were exposed to suspensions of these dilutions under semi-static conditions for 90 days. Analysis of muscle tissue by high resolution gas chromatography and mass spectrometry and of bile liquid by high-performance liquid chromatography showed that particle-bound PCDD/Fs, PCBs and PAHs were readily bioavailable from re-suspended sediments. Uptake of these contaminants and the associated toxicological effects in fish were largely proportional to their sediment concentrations. The changes in the investigated biomarkers closely reflected the different sediment contamination levels: cytochrome P450 1A mRNA expression and 7-ethoxyresorufin-O-deethylase activity in fish livers responded immediately and with high sensitivity, while increased frequencies of micronuclei and other nuclear aberrations, as well as histopathological and gross pathological lesions, were strong indicators of the potential long-term effects of re-suspension events. Our study clearly demonstrates that sediment re-suspension can lead to accumulation of PCDD/Fs and PCBs in fish, resulting in potentially adverse toxicological effects. For a sound risk assessment within the implementation of the European Water Framework Directive and related legislation, we propose a strong emphasis on sediment-bound contaminants in the context of integrated river basin management plans.