6 resultados para Peak professional body
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
George Gaylord Simpson famously postulated that much of life's diversity originated as adaptive radiations-more or less simultaneous divergences of numerous lines from a single ancestral adaptive type. However, identifying adaptive radiations has proven difficult due to a lack of broad-scale comparative datasets. Here, we use phylogenetic comparative data on body size and shape in a diversity of animal clades to test a key model of adaptive radiation, in which initially rapid morphological evolution is followed by relative stasis. We compared the fit of this model to both single selective peak and random walk models. We found little support for the early-burst model of adaptive radiation, whereas both other models, particularly that of selective peaks, were commonly supported. In addition, we found that the net rate of morphological evolution varied inversely with clade age. The youngest clades appear to evolve most rapidly because long-term change typically does not attain the amount of divergence predicted from rates measured over short time scales. Across our entire analysis, the dominant pattern was one of constraints shaping evolution continually through time rather than rapid evolution followed by stasis. We suggest that the classical model of adaptive radiation, where morphological evolution is initially rapid and slows through time, may be rare in comparative data.
Resumo:
The effect of whole-body vibration dosage on leg blood flow was investigated. Nine healthy young adult males completed a set of 14 random vibration and non-vibration exercise bouts whilst squatting on a Galileo 900 plate. Six vibration frequencies ranging from 5 to 30 Hz (5 Hz increments) were used in combination with a 2.5 mm and 4.5 mm amplitude to produce twelve 1-min vibration bouts. Subjects also completed two 1-min bouts where no vibration was applied. Systolic and diastolic diameters of the common femoral artery and blood cell velocity were measured by an echo Doppler ultrasound in a standing or rest condition prior to the bouts and during and after each bout. Repeated measures MANOVAs were used in the statistical analysis. Compared with the standing condition, the exercise bouts produced a four-fold increase in mean blood cell velocity (P<0.001) and a two-fold increase in peak blood cell velocity (P<0.001). Compared to the non-vibration bouts, frequencies of 10-30 Hz increased mean blood cell velocity by approximately 33% (P<0.01) whereas 20-30 Hz increased peak blood cell velocity by approximately 27% (P<0.01). Amplitude was additive to frequency but only achieved significance at 30 Hz (P<0.05). Compared with the standing condition, squatting alone produced significant increases in mean and peak blood cell velocity (P<0.001). The results show leg blood flow increased during the squat or non-vibration bouts and systematically increased with frequency in the vibration bouts.
Resumo:
Gender-fair language, including women and men, such as word pairs has a substantial impact on the mental representation, as a large body of studies have shown. When using exclusively the masculine form as a generic, women are mentally significantly less represented than men. Word pairs, however, lead to a higher cognitive inclusion of women. Surprisingly little research has been conducted to understand how the perception of professional groups is affected by gender-fair language. Providing evidence from an Italian-Austrian cross-cultural study with over 400 participants, we argue that gender-fair language impacts the perception of professional groups, in terms of perceived gender-typicality, number of women and men assumed for a profession, social status and average income. Results hint at a pervasive pay-off: on the one hand, gender-fair language seems to boost the mental representations in favor of women and professions are perceived as being rather gender-neutral. On the other hand professional groups are assigned lower salary and social status with word pairs. Implications of results are discussed.
Resumo:
BACKGROUND Rising levels of overweight and obesity are important public-health concerns worldwide. The purpose of this study is to elucidate their prevalence and trends in Switzerland by analyzing variations in Body Mass Index (BMI) of Swiss conscripts. METHODS The conscription records were provided by the Swiss Army. This study focussed on conscripts 18.5-20.5 years of age from the seven one-year birth cohorts spanning the period 1986-1992. BMI across professional status, area-based socioeconomic position (abSEP), urbanicity and regions was analyzed. Two piecewise quantile regression models with linear splines for three birth-cohort groups were used to examine the association of median BMI with explanatory variables and to determine the extent to which BMI has varied over time. RESULTS The study population consisted of 188,537 individuals. Median BMI was 22.51 kg/m2 (22.45-22.57 95% confidence interval (CI)). BMI was lower among conscripts of high professional status (-0.46 kg/m2; 95% CI: -0.50, -0.42, compared with low), living in areas of high abSEP (-0.11 kg/m2; 95% CI: -0.16, -0.07 compared to medium) and from urban communities (-0.07 kg/m2; 95% CI: -0.11, -0.03, compared with peri-urban). Comparing with Midland, median BMI was highest in the North-West (0.25 kg/m2; 95% CI: 0.19-0.30) and Central regions (0.11 kg/m2; 95% CI: 0.05-0.16) and lowest in the East (-0.19 kg/m2; 95% CI: -0.24, -0.14) and Lake Geneva regions (-0.15 kg/m2; 95% CI: -0.20, -0.09). Trajectories of regional BMI growth varied across birth cohorts, with median BMI remaining high in the Central and North-West regions, whereas stabilization and in some cases a decline were observed elsewhere. CONCLUSIONS BMI of Swiss conscripts is associated with individual and abSEP and urbanicity. Results show regional variation in the levels and temporal trajectories of BMI growth and signal their possible slowdown among recent birth cohorts.
Resumo:
The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.
Resumo:
Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.