20 resultados para Pain Threshold
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Our aim was to distinguish between spinal and supraspinal mechanisms in the intact nervous system by comparing homosegmental and heterosegmental effects of electroacupuncture (EA) and manual acupuncture (MA) on sensory perception in healthy volunteers by means of quantitative sensory testing. Seventy-two healthy volunteers were randomly assigned to receive either MA or EA at SP 6, SP 9, GB 39, and ST 36 at the left leg or relaxed for 30 minutes (control group [CG]). Blinded examiners assessed 13 sensory modalities (thermal and mechanical detection and pain thresholds) at the upper arms and lower legs before and after intervention by means of a standardized quantitative sensory testing battery. Change scores of all 13 sensory thresholds were compared between groups. The main outcome measure was the change score of the pressure pain threshold (PPT). There were no baseline differences between groups. Pressure pain threshold change scores at the lower left leg, in the same segment as the needling site, differed significantly (P = 0.008) between the EA (median: 103.01 kPa) and CG groups (median: 0.00 kPa) but not between the MA (median: 0.00 kPa) and CG groups. No further significant change score differences were found between one of the acupuncture groups and the CG. The PPT can be changed by EA. The PPT increase was confined to the segment of needling, which indicates that it is mainly mediated by segmental inhibition in the spinal cord. This underscores the importance of segmental needling and electrical stimulation in clinical practice.
Resumo:
OBJECTIVES: Sensory hypersensitivity, central hyperexcitability [lowered nociceptive flexion reflex (NFR) thresholds], and psychologic distress are features of chronic whiplash. However, relationships between these substrates are not clear. This study tested the hypothesis that psychologic distress and catastrophization are correlated with sensory hypersensitivity and NFR responses in chronic whiplash. METHODS: Pressure and thermal pain thresholds (mean values across 3 body sites), NFR threshold, and pain at threshold Visual Analog Scale were measured in 30 participants with chronic whiplash and 30 asymptomatic controls. Pain and disability levels Neck Disability Index, psychologic distress (GHQ-28), and catastrophization (PCS) were also measured in the whiplash group. RESULTS: Whiplash injured participants demonstrated lowered pain thresholds to pressure and cold (P<0.05); lowered NFR thresholds (P=0.003), and demonstrated above threshold levels of psychologic distress (GHQ-28) and levels of catastrophization comparable with other musculoskeletal conditions. There were no group differences for heat pain thresholds or pain at NFR threshold. In the whiplash group, PCS scores correlated moderately with cold pain threshold (r=0.51, P=0.01). In contrast, there were no significant correlations between GHQ-28 scores and pain threshold measures or between psychologic factors and NFR responses in whiplash participants. There were no significant correlations between psychologic factors and pain thresholds or NFR responses in controls. DISCUSSION: We have demonstrated that psychologic factors have some association with sensory hypersensitivity (cold pain threshold measures) in chronic whiplash but do not seem to influence spinal cord excitability. This suggests that psychologic disorders are important, but not the only, determinants of central hypersensitivity in whiplash patients.
Resumo:
Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.
Resumo:
OBJECTIVE: The primary aim of the present study was to investigate whether there is a relationship between central hypersensitivity (assessed by pressure pain thresholds of uninjured tissues) and intradiscal pain threshold during discography. The secondary aim was to test the hypothesis that peripheral noxious stimulation dynamically modulates central hypersensitivity. PATIENTS: Twenty-four patients with positive provocation discography were tested for central hypersensitivity by pressure algometry before and after the intervention with assessments of pressure pain detection and tolerance thresholds. Intradiscal pain threshold was assessed by measuring intradiscal pressure at the moment of pain provocation during discography. Correlation analyses between intradiscal pain threshold and pressure algometry were made. For the secondary aim, pressure algometry data before and after discography were compared. RESULTS: Significant correlation with intradiscal pain threshold was found for pressure pain detection threshold at the toe (regression coefficient: 0.03, P = 0.05) and pressure pain tolerance thresholds at the nonpainful point at the back (0.02, P = 0.024). Tolerance threshold at the toe was a significant predictor for intradiscal pain threshold only in multiple linear regression (0.036, P = 0.027). Detection as well as tolerance thresholds significantly decreased after discography at the painful and the nonpainful point at the back, but not at the toe. CONCLUSIONS: Central hypersensitivity may influence intradiscal pain threshold, but with a modest quantitative impact. The diagnostic value of provocation discography is therefore not substantially impaired. Regional, but not generalized central hypersensitivity is dynamically modulated by ongoing peripheral nociceptive input.
Resumo:
The activation of 5-hydroxytryptamine-3 (5-HT-3) receptors in spinal cord can enhance intrinsic spinal mechanisms of central hypersensitivity, possibly leading to exaggerated pain responses. Clinical studies suggest that 5-HT-3 receptor antagonists may have an analgesic effect. This randomized, double-blind, placebo-controlled crossover study tested the hypothesis that the 5-HT-3 receptor antagonist tropisetron attenuates pain and central hypersensitivity in patients with chronic low back pain. Thirty patients with chronic low back pain, 15 of whom were women (aged 53 ± 14 years) and 15 men (aged 48 ± 14 years), were studied. A single intravenous injection of 0.9% saline solution, tropisetron 2mg, and tropisetron 5mg was administrated in 3 different sessions, in a double-blind crossover manner. The main outcome was the visual analogue scale (VAS) score of spontaneous low back pain before, and 15, 30, 60, and 90 minutes after drug administration. Secondary outcomes were nociceptive withdrawal reflexes to single and repeated electrical stimulation, area of reflex receptive fields, pressure pain detection and tolerance thresholds, conditioned pain modulation, and area of clinical pain. The data were analyzed by analysis of variance and panel multiple regressions. All 3 treatments reduced VAS scores. However, there was no statistically significant difference between tropisetron and placebo in VAS scores. Compared to placebo, tropisetron produced a statistically significant increase in pain threshold after single electrical stimulation, but no difference in all other secondary outcomes was found. A single-dose intravenous administration of tropisetron in patients with chronic low back pain had no significant specific effect on intensity of pain and most parameters of central hypersensitivity.
Resumo:
Low back pain is associated with plasticity changes and central hypersensitivity in a subset of patients. We performed a case-control study to explore the discriminative ability of different quantitative sensory tests in distinguishing between 40 cases with chronic low back pain and 300 pain-free controls, and to rank these tests according to the extent of their association with chronic pain. Gender, age, height, weight, body mass index, and psychological measures were recorded as potential confounders. We used 26 quantitative sensory tests, including different modalities of pressure, heat, cold, and electrical stimulation. As measures of discrimination, we estimated receiver operating characteristics (ROC) and likelihood ratios. Six tests seemed useful (in order of their discriminative ability): (1) pressure pain detection threshold at the site of most severe pain (fitted area under the ROC, 0.87), (2) single electrical stimulation pain detection threshold (0.87), (3) single electrical stimulation reflex threshold (0.83), (4) pressure pain tolerance threshold at the site of most severe pain (0.81), (5) pressure pain detection threshold at suprascapular region (0.80), and (6) temporal summation pain threshold (0.80). Pressure and electrical pain modalities seemed most promising and may be used for diagnosis of pain hypersensitivity and potentially for identifying individuals at risk of developing chronic low back pain over time.
Resumo:
BACKGROUND Chronic pain is associated with generalized hypersensitivity and impaired endogenous pain modulation (conditioned pain modulation; CPM). Despite extensive research, their prevalence in chronic pain patients is unknown. This study investigated the prevalence and potential determinants of widespread central hypersensitivity and described the distribution of CPM in chronic pain patients. METHODS We examined 464 consecutive chronic pain patients for generalized hypersensitivity and CPM using pressure algometry at the second toe and cold pressor test. Potential determinants of generalized central hypersensitivity were studied using uni- and multivariate regression analyses. Prevalence of generalized central hypersensitivity was calculated for the 5th, 10th and 25th percentile of normative values for pressure algometry obtained by a previous large study on healthy volunteers. CPM was addressed on a descriptive basis, since normative values are not available. RESULTS Depending on the percentile of normative values considered, generalized central hypersensitivity affected 17.5-35.3% of patients. 23.7% of patients showed no increase in pressure pain threshold after cold pressor test. Generalized central hypersensitivity was more frequent and CPM less effective in women than in men. Unclearly classifiable pain syndromes showed higher frequencies of generalized central hypersensitivity than other pain syndromes. CONCLUSIONS Although prevalent in chronic pain, generalized central hypersensitivity is not present in every patient. An individual assessment is therefore required in order to detect altered pain processing. The broad basic knowledge about central hypersensitivity now needs to be translated into concrete clinical consequences, so that patients can be offered an individually tailored mechanism-based treatment.
Resumo:
BACKGROUND AND OBJECTIVES Quantitative sensory testing (QST) is widely used to investigate peripheral and central sensitization. However, the comparative performance of different QST for diagnostic or prognostic purposes is unclear. We explored the discriminative ability of different quantitative sensory tests in distinguishing between patients with chronic neck pain and pain-free control subjects and ranked these tests according to the extent of their association with pain hypersensitivity. METHODS We performed a case-control study in 40 patients and 300 control subjects. Twenty-six tests, including different modalities of pressure, heat, cold, and electrical stimulation, were used. As measures of discrimination, we estimated receiver operating characteristic curves and likelihood ratios. RESULTS The following quantitative sensory tests displayed the best discriminative value: (1) pressure pain threshold at the site of the most severe neck pain (fitted area under the receiver operating characteristic curve, 0.92), (2) reflex threshold to single electrical stimulation (0.90), (3) pain threshold to single electrical stimulation (0.89), (4) pain threshold to repeated electrical stimulation (0.87), and (5) pressure pain tolerance threshold at the site of the most severe neck pain (0.86). Only the first 3 could be used for both ruling in and out pain hypersensitivity. CONCLUSIONS Pressure stimulation at the site of the most severe pain and parameters of electrical stimulation were the most appropriate QST to distinguish between patients with chronic neck pain and asymptomatic control subjects. These findings may be used to select the tests in future diagnostic and longitudinal prognostic studies on patients with neck pain and to optimize the assessment of localized and spreading sensitization in chronic pain patients.
Resumo:
The aim was to investigate the effect of mechanical pain stimulation at the lower back on hemodynamic and oxygenation changes in the prefrontal cortex (PFC) assessed by functional near-infrared spectroscopy (fNIRS) and on the partial pressure of end-tidal carbon dioxide ( PetCO 2) measured by capnography. 13 healthy subjects underwent three measurements (M) during pain stimulation using pressure pain threshold (PPT) at three locations, i.e., the processus spinosus at the level of L4 (M1) and the lumbar paravertebral muscles at the level of L1 on the left (M2) and the right (M3) side. Results showed that only in the M2 condition the pain stimulation elicited characteristic patterns consisting of (1) a fNIRS-derived decrease in oxy- and total hemoglobin concentration and tissue oxygen saturation, an increase in deoxy-hemoglobin concentration, (2) a decrease in the PetCO 2 response and (3) a decrease in coherence between fNIRS parameters and PetCO 2 responses in the respiratory frequency band (0.2-0.5 Hz). We discuss the comparison between M2 vs. M1 and M3, suggesting that the non-significant findings in the two latter measurements were most likely subject to effects of the different stimulated tissues, the stimulated locations and the stimulation order. We highlight that PetCO 2 is a crucial parameter for proper interpretation of fNIRS data in experimental protocols involving pain stimulation. Together, our data suggest that the combined fNIRS-capnography approach has potential for further development as pain monitoring method, such as for evaluating clinical pain treatment.
Resumo:
Hypersensitivity of pain pathways is considered a relevant determinant of symptoms in chronic pain patients, but data on its prevalence are very limited. To our knowledge, no data on the prevalence of spinal nociceptive hypersensitivity are available. We studied the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity in 961 consecutive patients with various chronic pain conditions. Pain threshold and nociceptive withdrawal reflex threshold to electrical stimulation were used to assess pain hypersensitivity and spinal nociceptive hypersensitivity, respectively. Using 10th percentile cutoff of previously determined reference values, the prevalence of pain hypersensitivity and spinal nociceptive hypersensitivity (95% confidence interval) was 71.2 (68.3-74.0) and 80.0 (77.0-82.6), respectively. As a secondary aim, we analyzed demographic, psychosocial, and clinical characteristics as factors potentially associated with pain hypersensitivity and spinal nociceptive hypersensitivity using logistic regression models. Both hypersensitivity parameters were unaffected by most factors analyzed. Depression, catastrophizing, pain-related sleep interference, and average pain intensity were significantly associated with hypersensitivity. However, none of them was significant for both unadjusted and adjusted analyses. Furthermore, the odds ratios were very low, indicating modest quantitative impact. To our knowledge, this is the largest prevalence study on central hypersensitivity and the first one on the prevalence of spinal nociceptive hypersensitivity in chronic pain patients. The results revealed an impressively high prevalence, supporting a high clinical relevance of this phenomenon. Electrical pain thresholds and nociceptive withdrawal reflex explore aspects of pain processing that are mostly independent of sociodemographic, psychological, and clinical pain-related characteristics.
Resumo:
Assessments of spinal nociceptive withdrawal reflexes can be used in human research both to evaluate the effect of analgesics and explore pain mechanisms related to sensitization. Before the reflex can be used as a clinical tool, normative values need to be determined in large scale studies. The aim of this study was to determine the reference values of spinal nociceptive reflexes and subjective pain thresholds (to single and repeated stimulation), and of the area of the reflex receptive fields (RRF) in 300 pain-free volunteers. The influences of gender, age, height, weight, body-mass index (BMI), body side of testing, depression, anxiety, catastrophizing and parameters of Short-Form 36 (SF-36) were analyzed by multiple regressions. The 95% confidence intervals were determined for all the tests as normative values. Age had a statistically and quantitatively significant impact on the subjective pain threshold to single stimuli. The reflex threshold to single stimulus was lower on the dominant compared to the non-dominant side. Depression had a negative impact on the subjective pain threshold to single stimuli. All the other analyses either did not reveal statistical significance or displayed quantitatively insignificant correlations. In conclusion, normative values of parameters related to the spinal nociceptive reflex were determined. This allows their clinical application for assessing central hyperexcitability in individual patients. The parameters investigated explore different aspects of sensitization processes that are largely independent of demographic characteristics, cognitive and affective factors.
Resumo:
BACKGROUND: Constipation is a significant side effect of opioid therapy. We have previously demonstrated that naloxone-3-glucuronide (NX3G) antagonizes the motility-lowering-effect of morphine in the rat colon. AIM: To find out whether oral NX3G is able to reduce the morphine-induced delay in colonic transit time (CTT) without being absorbed and influencing the analgesic effect. METHODS: Fifteen male volunteers were included. Pharmacokinetics: after oral administration of 0.16 mg/kg NX3G, blood samples were collected over a 6-h period. Pharmacodynamics: NX3G or placebo was then given at the start time and every 4 h thereafter. Morphine (0.05 mg/kg) or placebo was injected s.c. 2 h after starting and thereafter every 6 h for 24 h. CTT was measured over a 48-h period by scintigraphy. Pressure pain threshold tests were performed. RESULTS: Neither NX3G nor naloxone was detected in the venous blood. The slowest transit time was observed during the morphine phase, which was significantly different from morphine with NX3G and placebo. The pain perception was not significantly influenced by NX3G. CONCLUSIONS: Orally administered NX3G is able to reverse the morphine-induced delay of CTT in humans without being detected in peripheral blood samples. Therefore, NX3G may improve symptoms of constipation in-patients using opioid medication without affecting opioid-analgesic effects.
Resumo:
BACKGROUND The effect of acupuncture on sensory perception has never been systematically reviewed; although, studies on acupuncture mechanisms are frequently based on the idea that changes in sensory thresholds reflect its effect on the nervous system. METHODS Pubmed, EMBASE and Scopus were screened for studies investigating the effect of acupuncture on thermal or mechanical detection or pain thresholds in humans published in English or German. A meta-analysis of high quality studies was performed. RESULTS Out of 3007 identified articles 85 were included. Sixty five studies showed that acupuncture affects at least one sensory threshold. Most studies assessed the pressure pain threshold of which 80% reported an increase after acupuncture. Significant short- and long-term effects on the pressure pain threshold in pain patients were revealed by two meta-analyses including four and two high quality studies, respectively. In over 60% of studies, acupuncture reduced sensitivity to noxious thermal stimuli, but measuring methods might influence results. Few but consistent data indicate that acupuncture reduces pin-prick like pain but not mechanical detection. Results on thermal detection are heterogeneous. Sensory threshold changes were equally frequent reported after manual acupuncture as after electroacupuncture. Among 48 sham-controlled studies, 25 showed stronger effects on sensory thresholds through verum than through sham acupuncture, but in 9 studies significant threshold changes were also observed after sham acupuncture. Overall, there is a lack of high quality acupuncture studies applying comprehensive assessments of sensory perception. CONCLUSIONS Our findings indicate that acupuncture affects sensory perception. Results are most compelling for the pressure pain threshold, especially in pain conditions associated with tenderness. Sham acupuncture can also cause such effects. Future studies should incorporate comprehensive, standardized assessments of sensory profiles in order to fully characterize its effect on sensory perception and to explore the predictive value of sensory profiles for the effectiveness of acupuncture.
Resumo:
BACKGROUND Delayed-onset muscle soreness (DOMS) is a common symptom in people participating in exercise, sport, or recreational physical activities. Several remedies have been proposed to prevent and alleviate DOMS. DESIGN AND METHODS A five-arm randomized controlled study was conducted to examine the effects of acupuncture on eccentric exercise-induced DOMS of the biceps brachii muscle. Participants were recruited through convenience sampling of students and general public. Participants were randomly allocated to needle, laser, sham needle, sham laser acupuncture, and no intervention. Outcome measures included pressure pain threshold (PPT), pain intensity (visual analog scale), and maximum isometric voluntary force. RESULTS Delayed-onset muscle soreness was induced in 60 participants (22 females, age 23.6 ± 2.8 years, weight 66.1 ± 9.6 kg, and height 171.6 ± 7.9 cm). Neither verum nor sham interventions significantly improved outcomes within 72 hours when compared with no treatment control (P > 0.05). CONCLUSIONS Acupuncture was not effective in the treatment of DOMS. From a mechanistic point of view, these results have implications for further studies: (1) considering the high-threshold mechanosensitive nociceptors of the muscle, the cutoff for PPT (5 kg/cm) chosen to avoid bruising might have led to ceiling effects; (2) the traditional acupuncture regimen, targeting muscle pain, might have been inappropriate as the DOMS mechanisms seem limited to the muscular unit and its innervation. Therefore, a regionally based regimen including an intensified intramuscular needling (dry needling) should be tested in future studies, using a higher cutoff for PPT to avoid ceiling effects.
Resumo:
OBJECTIVES:: Widespread central hypersensitivity and altered conditioned pain modulation (CPM) have been documented in chronic pain conditions. Information on their prognostic values is limited. This study tested the hypothesis that widespread central hypersensitivity (WCH) and altered CPM, assessed during the chronic phase of low back and neck pain, predict poor outcome. METHODS:: A total of 169 consecutive patients with chronic low back or neck pain, referred to the pain clinic during 1 year, were analyzed. Pressure pain tolerance threshold at the second toe and tolerance time during cold pressor test at the hand assessed WCH. CPM was measured by the change in pressure pain tolerance threshold (test stimulus) after cold pressor test (conditioning stimulus). A structured telephone interview was performed 12 to 15 months after testing to record outcome parameters. Linear regression models were used, with average and maximum pain intensity of the last 24 hours at follow-up as endpoints. Multivariable analyses included sex, age, catastrophizing scale, Beck Depression Inventory, pain duration, intake of opioids, and type of pain syndrome. RESULTS:: Statistically significant reductions from baseline to follow-up were observed in pain intensity (P<0.001). No evidence for an association between the measures of WCH or CPM and intensity of chronic pain at follow-up was found. DISCUSSION:: A major predictive value of the measures that we used is unlikely. Future studies adopting other assessment modalities and possibly standardized treatments are needed to further elucidate the prognostic value of WCH and altered CPM in chronic pain.