16 resultados para PERFORATIONS

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To prove safety and feasibility of an intra-abdominal endoscopic evaluation via an iatrogenic uterine perforation that occurred during operative hysteroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iatrogenic free wall cardiac perforation is a rare but serious complication encountered during percutaneous cardiac procedures, which usually leads to tamponade and death. Septal occluder devices have been developed for sealing intracardiac shunts but may be also used in this emergency setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Distraction of the periosteum results in the formation of new bone in the gap between the periosteum and the original bone. We postulate that the use of a barrier membrane would be beneficial for new bone formation in periosteal distraction. Methods: To selectively influence the contribution of the periosteum, a distraction plate with perforations was used alone or covered by a collagen barrier membrane. All animals were subjected to a 7-day latency period and a 10-day distraction period with a rate of 0.1 mm/day. Four animals per group with or without a barrier membrane were sacrificed at 2, 4, and 6 weeks after the end of the distraction. The height of new bone generated relative to the areas bound by the parent bone and the periosteum was determined by histomorphometric methods. Results: New bone was found in all groups. At the periphery of the distraction plate, significant differences in bone height were found between the hinge and the distraction screw for the group without barrier membrane at 2 weeks (0.39 ± 0.19 mm) compared to 4 weeks (0.84 ± 0.44 mm; P = 0.002) and 6 weeks (1.06 ± 0.39 mm; P = 0.004). Differences in maximum bone height with and without a barrier membrane were observed laterally to the distraction plate at 2 weeks (1.22 ± 0.64 versus 0.55 ± 0.14 mm; P = 0.019) and 6 weeks (1.61 ± 0.56 versus 0.73 ± 0.33 mm; P = 0.003) of the consolidation period. Conclusion: Within the limitations of the present study, the application of a barrier membrane may be considered beneficial for new bone formation induced by periosteal distraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The relative contributions of different, potential factors to new bone formation in periosteal distraction osteogenesis are unknown. Purpose: The aim of the present study was to assess the influence of original bone and periosteum on bone formation during periosteal distraction osteogenesis in a rat calvarial model by means of histology and histomorphometry. Methods: A total of 48 rats were used for the experiment. The contribution of the periosteum was assessed by either intact or incised periosteum or an occlusive versus a perforated distraction plate. The cortical bone was either left intact or perforated. Animals were divided in eight experimental groups considering the three possible treatment modalities. All animals were subjected to a 7-day latency period, a 10-day distraction period and a 7-day consolidation period. The newly formed bone was analyzed histologically and histomorphometrically. Results: New, mainly woven bone was found in all groups. Differences in the maximum height of new bone were observed and depended on location. Under the distraction plate, statistically significant differences in maximum bone height were found between the group with perforations in both cortical bone and distraction plate and the group without such perforations. Conclusions: If the marrow cavities were not opened, the contribution to new bone formation was dominant from the periosteum. If the bone perforations opened the marrow cavities, a significant contribution to new bone formation originated from the native bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Osteoporosis is not only responsible for an increased number of metaphyseal and spinal fractures but it also complicates their treatment. To prevent the initial loosening, we developed a new implant with an enlarged implant/bone interface based on the concept of perforated, hollow cylinders. We evaluated whether osseointegration of a hollow cylinder based implant takes place in normal or osteoporotic bone of sheep under functional loading conditions during anterior stabilization of the lumbar spine. MATERIALS AND METHODS: Osseointegration of the cylinders and status of the fused segments (ventral corpectomy, replacement with iliac strut, and fixation with testing implant) were investigated in six osteoporotic (age 6.9 +/- 0.8 years, mean body weight 61.1 +/- 5.2 kg) and seven control sheep (age 6.1 +/- 0.2 years, mean body weight 64.9 +/- 5.7 kg). Osteoporosis was introduced using a combination protocol of ovariectomy, high-dose prednisone, calcium and phosphor reduced diet and movement restriction. Osseointegration was quantified using fluorescence and conventional histology; fusion status was determined using biomechanical testing of the stabilized segment in a six-degree-of-freedom loading device as well as with radiological and histological staging. RESULTS: Intact bone trabeculae were found in 70% of all perforations without differences between the two groups (P = 0.26). Inside the cylinders, bone volume/total volume was significantly higher than in the control vertebra (50 +/- 16 vs. 28 +/- 13%) of the same animal (P<0.01), but significantly less (P<0.01) than in the near surrounding (60 +/- 21%). After biomechanical testing as described in Sect. "Materials and methods", seven spines (three healthy and four osteoporotic) were classified as completely fused and six (four healthy and two osteoporotic) as not fused after a 4-month observation time. All endplates were bridged with intact trabeculae in the histological slices. CONCLUSIONS: The high number of perforations, filled with intact trabeculae, indicates an adequate fixation; bridging trabeculae between adjacent endplates and tricortical iliac struts in all vertebrae indicates that the anchorage is adequate to promote fusion in this animal model, even in the osteoporotic sheep.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Currently available devices for transcatheter closure of patent foramen ovale (PFO) which rely on a permanent implant have limitations, including late complications. The study objective was to evaluate the safety, feasibility, and effectiveness of the PFx Closure System, the first transcatheter technique for PFO closure without an implantable device. METHODS AND RESULTS: A prospective study of 144 patients was conducted at nine clinical sites from October 2005 through August 2007. All patients had a history of cryptogenic stroke, transient ischemic attack, migraines, or decompression illness. The mean balloon stretched diameter of the PFO was 7.9 +/- 2.5 mm. Technical success (successful application of radiofrequency energy) was achieved in 130 patients. One patient required a transfusion as a result of blood loss during the procedure. There were no other major procedural complications. There were no recurrent strokes, deaths, conduction abnormalities, or perforations following the procedure. At a mean follow-up of 6 months, successful closure was achieved in 79 patients (55%). In PFOs with balloon sized or stretched diameters less than 8 mm, the closure rate was 72% (53/74). CONCLUSION: This study demonstrates that transcatheter closure of a PFO without a permanent implant is technically feasible and safe. Further technique and device modifications are required to achieve higher closure rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Distinct Crohn's disease (CD) phenotypes correlate with antibody reactivity to microbial antigens. We examined the association between antibody response to 2 new flagellins called A4-Fla2 and Fla-X, anti-Saccharomyces cerevisiae antibodies (ASCA), anti-neutrophil cytoplasmic antibodies (p-ANCA), anti-pancreas antibodies (PAB), NOD2 mutations (R702W, G908R, and L1007fsinsC), and clinical CD phenotypes (according to Vienna criteria). METHODS: All the above-mentioned antibodies as well as NOD2 mutations were determined in 252 CD patients, 53 with ulcerative colitis (UC), and 43 healthy controls (HC) and correlated with clinical data. RESULTS: A seroreactivity for A4-Fla2/Fla-X/ASCA/p-ANCA/PAB (in percent) was found in 59/57/62/12/22 of CD patients, 6/6/4/51/0 of UC patients, and 0/2/5/0/0 of healthy controls. CD behavior: 37% B1, 36% B2, and 27% B3. In multivariate logistic regression, antibodies to A4-Fla2, Fla-X, and ASCA were significantly associated with stricturing phenotype (P = 0.027, P = 0.041, P < 0.001), negative associations were found with inflammatory phenotype (P = 0.001, P = 0.005, P < 0.001). Antibodies to A4-Fla2, Fla-X, ASCA, and NOD2 mutations were significantly associated with small bowel disease (P = 0.013, P = 0.01, P < 0.001, P = 0.04), whereas ASCA was correlated with fistulizing disease (P = 0.007), and small bowel surgery (P = 0.009). Multiple antibody responses against microbial antigens were associated with stricturing (P < 0.001), fistulizing disease (P = 0.002), and small bowel surgery (P = 0.002). CONCLUSIONS: Anti-flagellin antibodies and ASCA are strongly associated with complicated CD phenotypes. CD patients with serum reactivity against multiple microbes have the greatest frequency of strictures, perforations, and small bowel surgery. Further prospective longitudinal studies are needed to show that antibody-based risk stratification improves the clinical outcome of CD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Little is known about the clinical importance of concomitant injuries in polytraumatized patients with high-grade blunt liver injury. A retrospective single-centre study was performed to investigate the safety of non-operative management of liver injury and the impact of concomitant intra- and extra-abdominal injuries on clinical outcome. METHODS: Some 183 patients with blunt liver injury were admitted to Berne University Hospital, Switzerland, between January 2000 and December 2006. Grade 3-5 injuries were considered to be high grade. RESULTS: Immediate laparotomy was required by 35 patients (19.1 per cent), owing to extrahepatic intra-abdominal injury (splenic and vascular injuries, perforations) in 21 cases. The mortality rate was 16.9 per cent; 22 of the 31 deaths were due to concomitant lesions. Of 81 patients with high-grade liver injury, 63 (78 per cent) were managed without surgery; liver-related and extra-abdominal complication rates in these patients were 11 and 17 per cent respectively. Grades 4 and 5 liver injury were associated with hepatic-related and extra-abdominal complications. CONCLUSION: Concomitant injuries are a major determinant of outcome in patients with blunt hepatic injury and should be given high priority by trauma surgeons. An algorithm for the management of blunt liver injury is proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The treatment of proximal humerus fractures in patients with poor bone quality remains a challenge in trauma surgery. Augmentation with polymethylmethacrylate (PMMA) cement is a possible method to strengthen the implant anchorage in osteoporotic bone and to avoid loss of reduction and reduce the cut-out risk. The polymerisation of PMMA during cement setting leads, however, to an exothermic reaction and the development of supraphysiological temperatures may harm the bone and cartilage. This study addresses the issue of heat development during augmentation of subchondrally placed proximal humerus plate screws with PMMA and the possible risk of bone and cartilage necrosis and apoptosis. METHODS Seven fresh frozen humeri from geriatric female donors were instrumented with the proximal humerus interlocking system (PHILOS) plate and placed in a 37°C water bath. Thereafter, four proximal perforated screws were augmented with 0.5 ml PMMA each. During augmentation, the temperatures in the subchondral bone and on the articular surface were recorded with K-type thermocouples. The measured temperatures were compared to threshold values for necrosis and apoptosis of bone and cartilage reported in the literature. RESULTS The heat development was highest around the augmented tips of the perforated screws and diminished with growing distance from the cement cloud. The highest temperature recorded in the subchondral bone reached 43.5°C and the longest exposure time above 42°C was 86s. The highest temperature measured on the articular surface amounted to 38.6°C and the longest exposure time above 38°C was 5 min and 32s. CONCLUSION The study shows that augmentation of the proximal screws of the PHILOS plate with PMMA leads to a locally limited development of supraphysiological temperatures in the cement cloud and closely around it. The critical threshold values for necrosis and apoptosis of cartilage and subchondral bone reported in the literature, however, are not reached. In order to avoid cement extravasation, special care should be taken in detecting perforations or intra-articular cracks in the humeral head.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Working hour limitations and tight health care budgets have posed significant challenges to emergency surgical services. Since 1 January 2010, surgical interventions at Berne University Hospital between 23:00 and 08:00 h have been restricted to patients with an expected serious adverse outcome if not operated on within 6 h. This study was designed to assess the safety of this new policy that restricts nighttime appendectomies (AEs). Methods The patients that underwent AE from 1 January 2010 to 31 December 2011 (“2010-2011 group”) were compared retrospectively with patients that underwent AE before introduction of the new policy (1 January 2006–31 December 2009; “2006-2009 group”). Results Overall, 390 patients were analyzed. There were 255 patients in the 2006–2009 group and 135 patients in the 2010–2011 group. Patients’ demographics did not differ statistically between the two study groups; however, 45.9 % of the 2006–2009 group and 18.5 % of the 2010–2011 group were operated between 23:00 and 08:00 h (p < 0.001). The rates of appendiceal perforations and surgical site infections did not differ statistically between the 2006–2009 group and the 2010–2011 group (20 vs. 18.5 %, p = 0.725 and 2 vs. 0 %, p = 0.102). Additionally, no difference was found for the hospital length of stay (3.9 ± 7.4 vs. 3.4 ± 6.0 days, p = 0.586). However, the proportion of patients with an in-hospital delay of >12 h was significantly greater in the 2010–2011 group than in the 2006–2009 group [55.6 vs. 43.5 %, p = 0.024, odds ratio (95 % confidence interval 1.62 (1.1–2.47)]. Conclusions Restricting AEs from 23:00 to 08:00 h does not increase the perforation rates and occurrence of clinical outcomes. Therefore, these results suggest that appendicitis may be managed safely in a semielective manner.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical and radiographic variables potentially influencing the risk of sinus membrane perforation were evaluated and divided into patient-related factors (age, sex, smoking habit); surgery-related factors (type of surgical approach, side, units, sites, and technique of osteotomy); and maxillary sinus-related factors (presence and height of septum, height of residual ridge, thickness of lateral sinus wall, width of antrum, and thickness and status of sinus membrane). RESULTS The following factors presented with at least a 10% difference in rates of perforations: smokers (46.2%) versus nonsmokers (23.4%), simultaneous (32%) versus staged (18.5%) approach, mixed premolar-molar sites (41.2%) versus premolar-only sites (16.7%) versus molar-only sites (26.2%), presence of septa (42.9%) versus no septa (23.8%), and minimum height of residual ridge ≤4 mm (34.2%) versus > 4 mm (20.5%). These same parameters, except minimum height of residual ridge, also showed an odds ratio above 2. However, none of the comparisons reached statistical significance. CONCLUSION The present study failed to demonstrate any factor that statistically significantly increased the risk of sinus membrane perforation during SFE using the lateral window approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION To present the accuracy of reduction, complications and results two years after open reduction and internal fixation of displaced acetabular fractures involving the anterior column (AC) through the Pararectus approach. Frequencies for conversion to total hip replacement in the early follow up, the clinical outcome in preserved hips, and the need for an extension of the approach (1st window of the ilioinguinal approach) are compared to the literature about the modified Stoppa approach. METHODS Forty-eight patients (mean age 62 years, range: 16–98; 41 male) with displaced acetabular fractures involving the AC (AC: n = 9; transverse fracture: n = 2; AC and hemitransverse: n = 24; both column: n = 13) were treated between 12/2009 and 12/2011 using the Pararectus approach. Surgical data and accuracy of reduction (using computed tomography) were assessed. Patients were routinely followed up at eight weeks, 6, 12 and 24 months postoperatively. Failure was defined as the need for total hip arthroplasty. Twenty-four months postoperatively the outcome was rated according to Matta. RESULTS In four patients there were four intraoperative complications (minor vascular damage in two, small perforations of the peritoneum in two) which were managed intraoperatively. Fracture reduction showed statistically significant decreases (mean ± SD, pre- vs. postoperative, in mm) in “step-offs”: 2.6 ± 1.9 vs. 0.1 ± 0.3, p < 0.001 and “gaps”: 11.2 ± 6.8 vs. 0.7 ± 0.9, p < 0.001. Accuracy of reduction was “anatomical” in 45, “imperfect” in three. Five (13%) from 38 available patients required a total hip arthroplasty. Of 33 patients with a preserved hip the clinical outcome was graded as “excellent” in 13 or “good” in 20; radiographically, 27 were graded as “excellent”, four as “good” and two as “fair”. An extension of the approach was infrequently used (1st window ilioinguinal approach in 2%, mini-incision at the iliac crest in 21%). CONCLUSION In the treatment of acetabular fractures involving the anterior column the Pararectus approach allowed for anatomic restoration with minimal access morbidity. Results obtained by means of the Pararectus approach after two years at least parallel those reported after utilisation of the modified Stoppa approach. In contrast to the modified Stoppa approach, a relevant extension of the Pararectus approach was almost not necessary.