396 resultados para PERCUTANEOUS VERTEBROPLASTY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have described 'open' approach techniques for cementation of sheep and goat vertebrae; however, no percutaneous technique has been developed so far for use in non-primates. The aim of this study was to develop an animal model for percutaneous vertebroplasty under clinical conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: A prospective case control study design was conducted. OBJECTIVES: The purpose of the current study was to determine the intraoperative radiation hazard to spine surgeons by occupational radiation exposure during percutaneous vertebroplasty and possible consequences with respect to radiation protection. SUMMARY OF BACKGROUND DATA: The development of minimally invasive surgery techniques has led to an increasing number of fluoroscopically guided procedures being done percutaneously such as vertebroplasty, which is the percutaneous cement augmentation of vertebral bodies. METHODS: Three months of occupational dose data for two spine surgeons was evaluated measuring the radiation doses to the thyroid gland, the upper extremities, and the eyes during vertebroplasty. RESULTS: The annual risk of developing a fatal cancer of the thyroid is 0.0025%, which means a very small to small risk. The annual morbidity (the risk of developing a cancer including nonfatal ones) is 0.025%, which already means a small to medium risk. The dose for the eye lens was about 8% of the threshold dose to develop a radiation induced cataract (150 mSv); therefore, the risk is very low but not negligible. The doses measured for the skin are 10% of the annual effective dose limit (500 mSv) recommended by the ICRP (International Commission on Radiologic Protection); therefore, the annual risk for developing a fatal skin cancer is very low. CONCLUSION: While performing percutaneous vertebroplasty, the surgeon is exposed to a significant amount of radiation. Proper surgical technique and shielding devices to decrease potentially high morbidity are mandatory. Training in radiation protection should be an integral part of the education for all surgeons using minimally invasive radiologic-guided interventional techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Vertebroplasty, kyphoplasty and lordoplasty are minimally invasive procedures mainly performed for refractory pain due to osteoporotic vertebral body fractures. This review summarizes recent findings on outcome, complications and their impact on anesthetic management. RECENT FINDINGS: Despite an increasing number of publications on surgical technique, therapeutic efficacy and side effects of these interventions, anesthetic management per se is hardly investigated. All three treatments provide similar pain relief. Adverse effects include local cement leakage and new fractures adjacent to augmented vertebrae. Asymptomatic pulmonary cement embolism occurs in 4.6-6.8% of patients depending on cement viscosity, injection pressure and number of injected vertebrae. Potentially life-threatening embolism of cement or fat may occur. Kyphoplasty and lordoplasty aim at correcting vertebral deformity and are equally effective; lordoplasty is substantially less expensive, however. The incidence of systemic cement or fat embolism is similar to that in vertebroplasty. Whereas vertebroplasty is mostly performed under local anesthesia and sedation, general anesthesia is required for kyphoplasty and lordoplasty. The anesthetic regimen follows the principles of anesthesia in the elderly population. SUMMARY: Vertebroplasty, kyphoplasty and lordoplasty are effective minimally invasive treatments for stable vertebral compression fractures without compression of the spinal canal. The anesthesiologist must be prepared to manage systemic cement or fat embolism.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Clinically, the displacement of intravertebral fat into the circulation during vertebroplasty is reported to lead to problems in elderly patients and can represent a serious complication, especially when multiple levels have to be treated. An in vitro study has shown the feasibility of removing intravertebral fat by pulsed jet-lavage prior to vertebroplasty, potentially reducing the embolization of bone marrow fat from the vertebral bodies and alleviating the cardiovascular changes elicited by pulmonary fat embolism. In this in vivo study, percutaneous vertebroplasty using polymethylmethacrylate (PMMA) was performed in three lumbar vertebrae of 11 sheep. In six sheep (lavage group), pulsed jet-lavage was performed prior to injection of PMMA compared to the control group of five sheep receiving only PMMA vertebroplasty. Invasive recording of blood pressures was performed continuously until 60 min after the last injection. Cardiac output and arterial blood gas parameters were measured at selected time points. Post mortem, the injected cement volume was measured using CT and lung biopsies were processed for assessment of intravascular fat. Pulsed jet-lavage was feasible in the in vivo setting. In the control group, the injection of PMMA resulted in pulmonary fat embolism and a sudden and significant increase in mean pulmonary arterial pressure. Pulsed jet-lavage prevented any cardiovascular changes and significantly reduced the severity of bone marrow fat embolization. Even though significantly more cement had been injected into the lavaged vertebral bodies, significantly fewer intravascular fat emboli were identified in the lung tissue. Pulsed jet-lavage prevented the cardiovascular complications after PMMA vertebroplasty in sheep and alleviated the severity of pulmonary fat embolism.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising of the injection of polymethylmethacrylate (PMMA) into vertebral bodies, is an efficient procedure to stabilize osteoporotic compression fractures as well as other weakening lesions. Besides fat embolism, cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the PMMA during injection plays a key role in this context. It was shown in vitro that the best way to lower the risk of cement leakage is to inject the cement at higher viscosity, which is requires high injection forces. Injection forces can be reduced by applying a newly developed lavage technique as it was shown in vitro using human cadaver vertebrae. The purpose of this study was to prove the in vitro results in an in vivo model. The investigation was incorporated in an animal study that was performed to evaluate the cardiovascular reaction on cement augmentation using the lavage technique. Injection forces were measured with instrumentation for 1 cc syringes, additionally acquiring plunger displacement. Averaged injection forces measured, ranged from 12 to 130 N and from 28 to 140 N for the lavage group and the control group, respectively. Normalized injection forces (by viscosity and injection speed) showed a trend to be lower for the lavage group in comparison to the control group (P = 0.073). In conclusion, the clinical relevance on the investigated lavage technique concerning lowering injection forces was only shown by trend in the performed animal study. However, it might well be that the effect is more pronounced for osteoporotic vertebral bodies.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising an injection of polymethylmethacrylate (PMMA) into vertebral bodies, is a practical procedure for the stabilization of osteoporotic compression fractures as well as other weakening lesions. Cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the material plays a key role in this context. In order to enhance the safety for the patient, a rheometer system was developed to measure the cement viscosity intraoperatively. For this development, it is of great importance to know the proper viscosity to start the procedure determined by experienced surgeons and the relation between the time period when different injection devices are used and the cement viscosity. The purpose of the study was to investigate the viscosity ranges for different injection systems during conventional vertebroplasty. Clinically observed viscosity values and related time periods showed high scattering. In order to get a better understanding of the clinical observations, cement viscosity during hardening at different ambient temperatures and by simulation of the body temperature was investigated in vitro. It could be concluded, that the direct viscosity assessment with a rheometer during vertebroplasty can help clinicians to define a lower threshold viscosity and thereby decrease the risk of leakage and make adjustments to their injection technique in real time. Secondly, the acceleration in hardening of PMMA-based cements at body temperature can be useful in minimizing leakages by addressing them with a short injection break.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous cement augmentation (vertebroplasty) was used for the first time in the 1980s, primarily for treatment of vertebral hemangioma [Galibert 1987]. It was only in the middle of the 1990s that it was used for treatment of metastases and increasingly for osteoporotic fractures of the spine [Cotten 1996; Weill 1996; Jensen 1997; Cortet 1999; Heini 2000]. In the meantime, this method has become established for treatment of painful osteoporotic fractures and for tumorous osteolysis of the spine. The clinical success rate is very high, with rapid pain relief in 70–90% of treated patients [Legroux-Gerot 2004; Zoarski 2002; Peh 2002; Barr 2000].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteolytic lesions of the spine (metastasis, myeloma) can be treated extremely efficiently by percutaneous cement injection. The treatment should be restricted to osteolytic lesions of the vertebral body, and only if a relevant mechanical deterioration is present. If the pedicles and/or the lamina are involved and if there is compression of the spinal canal, the treatment is no longer appropriate. The surgical technique is similar to the treatment of osteoporotic fractures; however, there is definitely a higher risk for cement leakage and the clinical outcome is not as predictable as in osteoporotic fracture treatment. It is important to realize that cement injection per se has no impact on the tumor itself, but provides stability to the vertebral body. An osteolytic lesion without mechanical compromise does not need a vertebroplasty. Patients with tumorous lesions of the spine should be followed by an interdisciplinary team of spine surgeon, oncologist and radio-oncologist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Leakage is the most common complication of percutaneous cement augmentation of the spine. The viscosity of the polymethylmethacrylate (PMMA) cement is strongly correlated with the likelihood of cement leakage. We hypothesized that cement leakage can be reduced by sequential cement injection in a vertebroplasty model. METHODS A standardized vertebral body substitute model, consisting of aluminum oxide foams coated by acrylic cement with a preformed leakage path, simulating a ventral vein, was developed. Three injection techniques of 6 ml PMMA were assessed: injection in one single step (all-in-one), injection of 1 ml at the first and 5 ml at the second step with 1 min latency in-between (two-step), and sequential injection of 0.5 ml with 1-min latency between the sequences (sequential). Standard PMMA vertebroplasty cement was used; each injection type was tested on ten vertebral body substitute models with two possible leakage paths per model. Leakage was assessed by radiographs using a zonal graduation: intraspongious = no leakage and extracortical = leakage. RESULTS The leakage rate was significantly lower in the "sequential" technique (2/20 leakages) followed by "two-step" (15/20) and "all-in-one" (20/20) techniques (p < 0.001). The RR for a cement leakage was 10.0 times higher in the "all-in-one" compared to the "sequential" group (95 % confidence intervals 2.7-37.2; p < 0.001). CONCLUSIONS The sequential cement injection is a simple approach to minimize the risk for leakage. Taking advantage of the temperature gradient between body and room temperature, it is possible to increase the cement viscosity inside the vertebra while keeping it low in the syringe. Using sequential injection of small cement volumes, further leakage paths are blocked before further injection of the low-viscosity cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence and independent predictors of significant atherosclerotic renal artery stenosis (RAS) in unselected hypertensive patients undergoing coronary angiography and to assess the 6-month outcome of those patients with a significant RAS. METHODS: One thousand, four hundred and three consecutive hypertensive patients undergoing drive-by renal arteriography were analyzed retrospectively. Univariate and multivariate logistic regression analyses were performed to identify independent predictors of RAS. In patients with significant RAS (>or=50% luminal narrowing), 6-month follow-up was assessed and outcome was compared between patients with or without renal revascularization. RESULTS: The prevalence of significant RAS was 8%. After multivariate analysis, coronary [odds ratio 5.3; 95% confidence interval (CI) 2.7-10.3; P < 0.0001], peripheral (odds ratio 3.3; 95% CI 2.0-5.5; P < 0.0001), and cerebral artery (odds ratio 2.8; 95% CI 1.5-5.3; P = 0.001) diseases, and impaired renal function (odds ratio 2.9; 95% CI 1.8-4.5; P < 0.0001) were found as independent predictors. At least one of these predictors was present in 96% of patients with RAS. In 74 patients (66%) with significant RAS, an ad hoc revascularization was performed. At follow-up, creatinine clearance was significantly higher in revascularized than in nonrevascularized patients (69.2 vs. 55.5 ml/min per 1.73 m, P = 0.029). By contrast, blood pressure was comparable between both groups, but nonrevascularized patients were taking significantly more antihypertensive drugs as compared with baseline (2.7 vs. 2.1, follow-up vs. baseline; P = 0.0066). CONCLUSION: The prevalence of atherosclerotic RAS in unselected hypertensive patients undergoing coronary angiography was low. Coronary, peripheral, and cerebral artery diseases, and impaired renal function were independent predictors of RAS. Ad hoc renal revascularization was associated with better renal function and fewer intake of antihypertensive drugs at follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a paucity of data on the success rates of achieving percutaneous epicardial access in different groups of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patent foramen ovale (PFO) has been linked to migraine, and an improvement in migraine prevalence or frequency has been reported after PFO closure for other reasons. We sought to identify whether there is a specific patient population of migraineurs which may be more susceptible to benefiting from PFO closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The management of insufficiency fractures of the tibial plateau in osteoporotic patients can be very challenging, since it is difficult to achieve a stable fixation, an essential condition for the patients' early mobilization. We present a minimally invasive technique for the treatment of proximal tibial plateau fractures, "tibiaplasty", using percutaneous polymethylmethacrylate augmentation. Five osteoporotic patients (7 fractures) with a non-traumatic insufficiency tibial plateau fracture were treated with this technique at the authors' institution from 2006 to 2008. The patients' median age was 79 (range 62-88) years. The intervention was performed percutaneously under general or spinal anesthesia; after the intervention, immediate full weight bearing was allowed. The technique was feasible in all patients and no complications related to the intervention were observed. All patients reported a relevant reduction in pain, were able to mobilize with full weight bearing and would undergo the operation again. No secondary loss of reduction or progression of arthrosis was observed in radiological controls; no revision surgery was required. Our initial results indicate that tibiaplasty is a good treatment option for the management of insufficiency in tibial plateau fractures in osteoporotic patients. The technique is minimally invasive, safe and allows immediate mobilization without restrictions. In our group of patients, we found excellent early to mid-term results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.