90 resultados para One Up Bond F

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION Fibrinogen storage disease (FSD) is characterized by hypofibrinogenemia and hepatic inclusions due to impaired release of mutant fibrinogen which accumulates and aggregates in the hepatocellular endoplasmic reticulum. Liver disease is variable. AIM We studied a new Swiss family with fibrinogen Aguadilla. In order to understand the molecular peculiarity of FSD mutations, fibrinogen Aguadilla and the three other causative mutations, all located in the γD domain, were modelled. METHOD The proband is a Swiss girl aged 4 investigated because of fatigue and elevated liver enzymes. Protein structure models were prepared using the Swiss-PdbViewer and POV-Ray software. RESULTS The proband was found to be heterozygous for fibrinogen Aguadilla: FGG Arg375Trp. Familial screening revealed that her mother and maternal grandmother were also affected and, in addition, respectively heterozygous and homozygous for the hereditary haemochromatosis mutation HFE C282Y. Models of backbone and side-chain interactions for fibrinogen Aguadilla in a 10-angstrom region revealed the loss of five H-bonds and the gain of one H-bond between structurally important amino acids. The structure predicted for fibrinogen Angers showed a novel helical structure in place of hole 'a' on the outer edge of γD likely to have a negative impact on fibrinogen assembly and secretion. CONCLUSION The mechanism by which FSD mutations generate hepatic intracellular inclusions is still not clearly established although the promotion of aberrant intermolecular strand insertions is emerging as a likely cause. Reporting new cases is essential in the light of novel opportunities of treatment offered by increasing knowledge of the degradation pathway and autophagy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To determine the effect on resin composite-to-dentin bond strength of incorporation of an acidic tin-chloride pretreatment in two adhesive systems. MATERIALS AND METHODS: Human molars were ground to expose mid-coronal dentin. For microtensile bond strength (μTBS) testing, dentin was treated with Optibond FL or Clearfil SE according to one of six protocols (n = 22/group). Group 1: Phosphoric acid etching, Optibond FL Prime, Optibond FL Adhesive (manufacturer's instructions; control); Group 2: Tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 3: Phosphoric acid etching, tin-chloride pretreatment, Optibond FL Prime, Optibond FL Adhesive; Group 4: Clearfil SE Primer, Clearfil SE Bond (manufacturer's instructions; control); Group 5: Phosphoric acid etching, Clearfil SE Primer, Clearfil SE Bond; and Group 6: Tin-chloride pretreatment, Clearfil SE Primer, Clearfil SE Bond. The molars were then built up with resin composite (Clearfil Majesty Esthetic). After storage (1 week, 100  % humidity, 37 °C) the μTBS was measured and failure mode was determined. Additionally, pretreated dentin surfaces were evaluated using SEM and EDX. The μTBS results were analyzed statistically by a Welch Two Sample t-test and a Kruskal-Wallis test followed by exact Wilcoxon rank sum tests with Bonferroni-Holm adjustment for multiple testing (α = 0.05). RESULTS: When Optibond FL was used, partial or total replacement of phosphoric acid with tin-chloride decreased μTBS significantly. In contrast, when Clearfil SE was used, inclusion of a tin-chloride pretreatment in the adhesive procedure increased μTBS significantly. CONCLUSIONS: Tin-chloride pretreatment had a beneficial influence on the bond promoting capacity of the MDP-containing adhesive system Clearfil SE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES The study investigated the modification of composite-to-enamel bond strength by pre-treatment of enamel with a concentrated, acidic SnCl2-solution. METHODS Six groups of flat human enamel specimens (n=44 per group) were treated as follows: OB-H: H3PO4 etching, Optibond FL application (primer+adhesive; manufacturer's instructions); OB-S: SnCl2 pre-treatment, Optibond FL application (primer+adhesive); OB-HS: H3PO4 etching+SnCl2 pre-treatment, Optibond FL application (primer+adhesive); CF-N: Clearfil SE application (primer+bond; manufacturer's instructions); CF-H: H3PO4 etching, Clearfil SE application (primer+bond); CF-S: SnCl2 pre-treatment, Clearfil SE application (primer+bond). Enamel specimens were then built up with resin composite (Clearfil Majesty Esthetic) and stored (100% humidity, 37 °C, 1 week). μTBS-measurement and failure mode analysis of one-half of the specimens were performed immediately after storage, while the other half was analysed after a thermocycling procedure (8500 cycles; 5 °C and 55 °C; dwell time 30s). Additional specimens were prepared for SEM- and EDX-analysis. RESULTS Highest values were measured for OB-H before and after thermocycling, lowest values for CF-N. Compared to OB-H treatment, OB-S treatment reduced μTBS before/after thermocycling by 23%/28% and OB-HS treatment by 8%/24% (except for OB-SH before (n.s.), all p≤0.001 compared to OB-H). In the Clearfil SE treated groups pre-treatment increased μTBS significantly compared to CF-N (before/after: CF-H: +46%/+70%; CF-S: +51%/42%; all p≤0.001). CONCLUSION Pre-treatment with H3PO4 or SnCl2 markedly increased the μTBS of Clearfil SE to enamel. However, thermocycling partly reduced the gain in μTBS obtained by SnCl2 pre-treatment. CLINICAL SIGNIFICANCE The application of an acidic and highly concentrated SnCl2 solution is a good option to increase the μTBS between enamel and a resin composite mediated by an adhesive system containing the multifunctional monomer MDP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin. Materials and Methods: Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests. Results: Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. Conclusion: Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence and independent predictors of significant atherosclerotic renal artery stenosis (RAS) in unselected hypertensive patients undergoing coronary angiography and to assess the 6-month outcome of those patients with a significant RAS. METHODS: One thousand, four hundred and three consecutive hypertensive patients undergoing drive-by renal arteriography were analyzed retrospectively. Univariate and multivariate logistic regression analyses were performed to identify independent predictors of RAS. In patients with significant RAS (>or=50% luminal narrowing), 6-month follow-up was assessed and outcome was compared between patients with or without renal revascularization. RESULTS: The prevalence of significant RAS was 8%. After multivariate analysis, coronary [odds ratio 5.3; 95% confidence interval (CI) 2.7-10.3; P < 0.0001], peripheral (odds ratio 3.3; 95% CI 2.0-5.5; P < 0.0001), and cerebral artery (odds ratio 2.8; 95% CI 1.5-5.3; P = 0.001) diseases, and impaired renal function (odds ratio 2.9; 95% CI 1.8-4.5; P < 0.0001) were found as independent predictors. At least one of these predictors was present in 96% of patients with RAS. In 74 patients (66%) with significant RAS, an ad hoc revascularization was performed. At follow-up, creatinine clearance was significantly higher in revascularized than in nonrevascularized patients (69.2 vs. 55.5 ml/min per 1.73 m, P = 0.029). By contrast, blood pressure was comparable between both groups, but nonrevascularized patients were taking significantly more antihypertensive drugs as compared with baseline (2.7 vs. 2.1, follow-up vs. baseline; P = 0.0066). CONCLUSION: The prevalence of atherosclerotic RAS in unselected hypertensive patients undergoing coronary angiography was low. Coronary, peripheral, and cerebral artery diseases, and impaired renal function were independent predictors of RAS. Ad hoc renal revascularization was associated with better renal function and fewer intake of antihypertensive drugs at follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Little information is available on a long-term follow-up in Bartter syndrome type I and II. METHODS: Clinical presentation, treatment and long-term follow-up (5.0-21, median 11 years) were evaluated in 15 Italian patients with homozygous (n = 7) or compound heterozygous (n = 8) mutations in the SLC12A1 (n = 10) or KCNJ1 (n = 5) genes. RESULTS: Thirteen new mutations were identified. The 15 children were born pre-term with a normal for gestational age body weight. Medical treatment at the last follow-up control included supplementation with potassium in 13, non-steroidal anti-inflammatory agents in 12 and gastroprotective drugs in five patients. At last follow-up, body weight and height were within normal ranges in the patients. Glomerular filtration rate was <90 mL/min/1.73 m(2) in four patients (one of them with a pathologically increased urinary protein excretion). In three patients, abdominal ultrasound detected gallstones. The group of patients with antenatal Bartter syndrome had a lower renin ratio (P < 0.05) and a higher standard deviation score (SDS) for height (P < 0.05) than a previously studied group of patients with classical Bartter syndrome. CONCLUSIONS: Patients with Bartter syndrome type I and II tend to present a satisfactory prognosis after a median follow-up of more than 10 years. Gallstones might represent a new complication of antenatal Bartter syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study evaluated the initial and the artificially aged push-out bond strength between ceramic and dentin produced by one of five resin cements. METHODS: Two-hundred direct ceramic restorations (IPS Empress CAD) were luted to standardized Class I cavities in extracted human molars using one of four self-adhesive cements (SpeedCEM, RelyX Unicem Aplicap, SmartCem2 and iCEM) or a reference etch-and-rinse resin cement (Syntac/Variolink II) (n=40/cement). Push-out bond strength (PBS) was measured (1) after 24h water storage (non-aged group; n=20/cement) or (2) after artificial ageing with 5000 thermal cycles followed by 6 months humid storage (aged group; n=20/cement). Nonparametrical ANOVA and pairwise Wilcoxon rank-sum tests with Bonferroni-Holm adjustment were applied for statistical analysis. The significance level was set at alpha=0.05. In addition, failure mode and fracture pattern were analyzed by stereomicroscope and scanning electron microscopy. RESULTS: Whereas no statistically significant effect of storage condition was found (p=0.441), there was a significant effect of resin cement (p<0.0001): RelyX Unicem showed significantly higher PBS than the other cements. Syntac/Variolink II showed significantly higher PBS than SmartCEM2 (p<0.001). No significant differences were found between SpeedCEM, SmartCem2, and iCEM. The predominant failure mode was adhesive failure of cements at the dentin interface except for RelyX Unicem which in most cases showed cohesive failure in ceramic. SIGNIFICANCE: The resin cements showed marked differences in push-out bond strength when used for luting ceramic restorations to dentin. Variolink II with the etch-and-rinse adhesive Syntac did not perform better than three of the four self-adhesive resin cements tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Practice guidelines are systematically developed statements and recommendations that assist the physicians and patients in making decisions about appropriate health care measures for specific clinical circumstances taking into account specific national health care structures. The 1(st) revision of the S-2k guideline of the German Sepsis Society in collaboration with 17 German medical scientific societies and one self-help group provides state-of-the-art information (results of controlled clinical trials and expert knowledge) on the effective and appropriate medical care (prevention, diagnosis, therapy and follow-up care) of critically ill patients with severe sepsis or septic shock. The guideline had been developed according to the "German Instrument for Methodological Guideline Appraisal" of the Association of the Scientific Medical Societies (AWMF). In view of the inevitable advancements in scientific knowledge and technical expertise, revisions, updates and amendments must be periodically initiated. The guideline recommendations may not be applied under all circumstances. It rests with the clinician to decide whether a certain recommendation should be adopted or not, taking into consideration the unique set of clinical facts presented in connection with each individual patient as well as the available resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of antiretroviral treatment (ART) programmes in sub-Saharan Africa is difficult because many patients are lost to follow-up. Outcomes in these patients are generally unknown but studies tracing patients have shown mortality to be high. We adjusted programme-level mortality in the first year of antiretroviral treatment (ART) for excess mortality in patients lost to follow-up.