12 resultados para Objective Monitoring
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Mapping and monitoring are believed to provide an early warning sign to determine when to stop tumor removal to avoid mechanical damage to the corticospinal tract (CST). The objective of this study was to systematically compare subcortical monopolar stimulation thresholds (1-20 mA) with direct cortical stimulation (DCS)-motor evoked potential (MEP) monitoring signal abnormalities and to correlate both with new postoperative motor deficits. The authors sought to define a mapping threshold and DCS-MEP monitoring signal changes indicating a minimal safe distance from the CST.
Resumo:
Objective: This case report describes the use of serial measurements of peripheral venous and abdominal fluid hematocrits as a guide to treatment in a dog with traumatic hemoabdomen. Material and methods: An 18-month-old, female mixed-breed dog was presented with traumatic hemoabdomen. The dog was treated with intravenous fluids, and concurrent measurements of venous and abdominal fluid hematocrits were performed. Results: The initial hematocrit values were 39% in venous blood and 42% in abdominal fluid. Following fluid therapy, the venous hematocrit decreased to 20%, whereas the abdominal hematocrit remained stable at 40%. Based on this finding severe ongoing intra-abdominal hemorrhage was ruled out, and the dog was treated conservatively. Conclusion and clinical relevance: Comparison of serial abdominal and venous hematocrits may be useful in assessing the need for surgical management in patients with traumatic hemoabdomen.
Resumo:
Especially in pharmacotherapeutic research, a variety of methods to monitor behavioural and psychological symptoms of dementia (BPSD) are currently being discussed. To date, the most frequently used of these are clinical scales, which, however, are subjective and highly dependent on personnel resources. In our study, we tested the usefulness of actigraphy as a more direct and objective way to measure day-night rhythm disturbances and agitated behaviour.After a baseline assessment, 24 patients with probable dementia of the Alzheimer type (NINCDS-ADRDA) and agitated behaviour received either 3 mg melatonin (n=7), 2.5 mg dronabinol (n=7), or placebo (n=10) for two weeks. In addition, 10 young and 10 elderly healthy subjects were examined as a control group. Motor activity levels were assessed using an actigraph worn continuously on the wrist of the non-dominant hand. At the beginning and the end of the study, patients' Neuropsychiatric Inventory (NPI) scores were also assessed.In the verum group, actigraphic nocturnal activity (P=0.001), NPI total score (P=0.043), and NPI agitation subscale score (P=0.032) showed significant reductions compared to baseline. The treatment-baseline ratio of nocturnal activity (P=0.021) and treatment-baseline difference of the nocturnal portion of 24 h activity (P=0.012) were reduced. Patients' baseline activity levels were similar to those seen in healthy elderly subjects. Younger healthy subjects exhibited higher motor activity even at night. There was no correlation between actigraphy and NPI.Both actigraphic measures and the gold standard clinical scale were able to distinguish between the verum and placebo groups. However, because they did not correlate with each other, they clearly represent different aspects of BPSD, each of which reacts differently to therapy. As a result, actigraphy may well come to play an important role in monitoring treatment success in BPSD.
Resumo:
BACKGROUND: Steam pops are a risk of irrigated radiofrequency catheter ablation (RFA) and may cause cardiac perforation. Data to guide radiofrequency (RF) energy titration to avoid steam pops are limited. OBJECTIVE: This study sought to assess the frequency and consequence of audible pops and to determine the feasibility of using the magnitude of impedance change to predict pops. METHODS: We reviewed consecutive endocardial open-irrigated RFA for ventricular tachycardia (VT) with continuously recorded ablation data in 142 patients with structural heart disease. Steam pops were defined as an audible pop associated with a sudden spike in impedance. Ablation lesions before or after pops served as controls. RESULTS: From a total of 4,107 ablation lesions, 62 (1.5%) steam pops occurred in 42 procedures in 38 patients. Perforation with tamponade occurred with 1 of 62 (2%) pops. Applications with pops had a greater impedance decrease (22 +/- 7 Omega vs. 18 +/- 8 Omega, P = .001) and a higher maximum power (45 +/- 5 W vs. 43 +/- 6 W, P = .011), but did not differ in maximum catheter tip temperature (40 degrees C +/- 4 degrees C vs. 40 degrees C +/- 4 degrees C, P = .180) from applications without pops. Eighty percent of pops occurred after impedance decreased by at least 18 Omega. CONCLUSION: During VT ablation with open irrigation, audible pops are infrequent and do not usually cause perforation. Limiting RF power to achieve an impedance decrease of <18 Omega is a feasible method of reducing the likelihood of a pop when perforation risk is of concern.
Resumo:
OBJECTIVE: We compared motor and movement thresholds to transcranial magnetic stimulation (TMS) in healthy subjects and investigated the effect of different coil positions on thresholds and MEP (motor-evoked potential) amplitudes. METHODS: The abductor pollicis brevis (APB) 'hot spot' and a standard scalp position were stimulated. APB resting motor threshold (APB MEP-MT) defined by the '5/10' electrophysiological method was compared with movement threshold (MOV-MT), defined by visualization of movements. Additionally, APB MEP-MTs were evaluated with the '3/6 method,' and MEPs were recorded at a stimulation intensity of 120% APB MEP-MT at each position. RESULTS: APB MEP-MTs were significantly lower by stimulation of the 'hot spot' than of the standard position, and significantly lower than MOV-MTs (n=15). There were no significant differences between the '3/6' and the '5/10' methods, or between APB MEP amplitudes by stimulating each position at 120% APB MEP-MT. CONCLUSIONS: Coil position and electrophysiological monitoring influenced motor threshold determinations. Performing 6 instead of 10 trials did not produce different threshold measurements. Adjustment of intensity according to APB MEP-MT at the stimulated position did not influence APB MEP amplitudes. SIGNIFICANCE: Standardization of stimulation positions, nomenclature and criteria for threshold measurements should be considered in design and comparison of TMS protocols.
Resumo:
Meat and meat products can be contaminated with different species of bacteria resistant to various antimicrobials. The human health risk of a type of meat or meat product carry by emerging antimicrobial resistance depends on (i) the prevalence of contamination with resistant bacteria, (ii) the human health consequences of an infection with a specific bacterium resistant to a specific antimicrobial and (iii) the consumption volume of a specific product. The objective of this study was to compare the risk for consumers arising from their exposure to antibiotic resistant bacteria from meat of four different types (chicken, pork, beef and veal), distributed in four different product categories (fresh meat, frozen meat, dried raw meat products and heat-treated meat products). A semi-quantitative risk assessment model, evaluating each food chain step, was built in order to get an estimated score for the prevalence of Campylobacter spp., Enterococcus spp. and Escherichia coli in each product category. To assess human health impact, nine combinations of bacterial species and antimicrobial agents were considered based on a published risk profile. The combination of the prevalence at retail, the human health impact and the amount of meat or product consumed, provided the relative proportion of total risk attributed to each category of product, resulting in a high, medium or low human health risk. According to the results of the model, chicken (mostly fresh and frozen meat) contributed 6.7% of the overall risk in the highest category and pork (mostly fresh meat and dried raw meat products) contributed 4.0%. The contribution of beef and veal was of 0.4% and 0.1% respectively. The results were tested and discussed for single parameter changes of the model. This risk assessment was a useful tool for targeting antimicrobial resistance monitoring to those meat product categories where the expected risk for public health was greater.
Resumo:
In all European Union countries, chemical residues are required to be routinely monitored in meat. Good farming and veterinary practice can prevent the contamination of meat with pharmaceutical substances, resulting in a low detection of drug residues through random sampling. An alternative approach is to target-monitor farms suspected of treating their animals with antimicrobials. The objective of this project was to assess, using a stochastic model, the efficiency of these two sampling strategies. The model integrated data on Swiss livestock as well as expert opinion and results from studies conducted in Switzerland. Risk-based sampling showed an increase in detection efficiency of up to 100% depending on the prevalence of contaminated herds. Sensitivity analysis of this model showed the importance of the accuracy of prior assumptions for conducting risk-based sampling. The resources gained by changing from random to risk-based sampling should be transferred to improving the quality of prior information.
Resumo:
Many Member States of the European Union (EU) currently monitor antimicrobial resistance in zoonotic agents, including Salmonella and Campylobacter. According to Directive 2003/99/EC, Member States shall ensure that the monitoring provides comparable data on the occurrence of antimicrobial resistance. The European Commission asked the European Food Safety Authority to prepare detailed specifications for harmonised schemes for monitoring antimicrobial resistance. The objective of these specifications is to lay down provisions for a monitoring and reporting scheme for Salmonella in fowl (Gallus gallus), turkeys and pigs, and for Campylobacter jejuni and Campylobacter coli in broiler chickens. The current specifications are considered to be a first step towards a gradual implementation of comprehensive antimicrobial resistance monitoring at the EU level. These specifications propose to test a common set of antimicrobial agents against available cut-off values and a specified concentration range to determine the susceptibility of Salmonella and Campylobacter. Using isolates collected through programmes in which the sampling frame covers all epidemiological units of the national production, the target number of Salmonella isolates to be included in the antimicrobial resistance monitoring per Member State per year is 170 for each study population (i.e., laying hens, broilers, turkeys and slaughter pigs). The target number of Campylobacter isolates to be included in the antimicrobial resistance monitoring per Member State per year is 170 for each study population (i.e., broilers). The results of the antimicrobial resistance monitoring are assessed and reported in the yearly national report on trends and sources of zoonoses, zoonotic agents and antimicrobial resistance.
Resumo:
Cost-efficient operation while satisfying performance and availability guarantees in Service Level Agreements (SLAs) is a challenge for Cloud Computing, as these are potentially conflicting objectives. We present a framework for SLA management based on multi-objective optimization. The framework features a forecasting model for determining the best virtual machine-to-host allocation given the need to minimize SLA violations, energy consumption and resource wasting. A comprehensive SLA management solution is proposed that uses event processing for monitoring and enables dynamic provisioning of virtual machines onto the physical infrastructure. We validated our implementation against serveral standard heuristics and were able to show that our approach is significantly better.
Resumo:
We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as on the amount and direction of collateral circulation. This setting allows us to relate CW-NIRS findings to brain specific perfusion changes. We focused our analysis on the transition from normal perfusion to vessel occlusion, i.e., before hypoxia becomes clinically apparent. The localization of the maximal response correlated either with the core (occlusion of the middle cerebral artery) or with the watershed areas (occlusion of the internal carotid artery) of the respective vascular territories. In one patient with clinically and angiographically confirmed insufficient collateral flow during carotid artery occlusion, the total hemoglobin concentration became significantly asymmetric, with decreased values in the ipsilateral watershed area and contralaterally increased values. Multichannel CW-NIRS monitoring might serve as an objective and early predictive marker of critical perfusion changes during interventions-to prevent hypoxic damage of the brain. It also might provide valuable human reference data on oxygenation changes as they typically occur during acute stroke.
Resumo:
INTRODUCTION Anatomic imaging alone is often inadequate for tuning systemic treatment for individual tumor response. Optically based techniques could potentially contribute to fast and objective response monitoring in personalized cancer therapy. In the present study, we evaluated the feasibility of dual-modality diffuse reflectance spectroscopy-autofluorescence spectroscopy (DRS-AFS) to monitor the effects of systemic treatment in a mouse model for hereditary breast cancer. METHODS Brca1(-/-); p53(-/-) mammary tumors were grown in 36 mice, half of which were treated with a single dose of cisplatin. Changes in the tumor physiology and morphology were measured for a period of 1 week using dual-modality DRS-AFS. Liver and muscle tissues were also measured to distinguish tumor-specific alterations from systemic changes. Model-based analyses were used to derive different optical parameters like the scattering and absorption coefficients, as well as sources of intrinsic fluorescence. Histopathologic analysis was performed for cross-validation with trends in optically based parameters. RESULTS Treated tumors showed a significant decrease in Mie-scattering slope and Mie-to-total scattering fraction and an increase in both fat volume fraction and tissue oxygenation after 2 days of follow-up. Additionally, significant tumor-specific changes in the fluorescence spectra were seen. These longitudinal trends were consistent with changes observed in the histopathologic analysis, such as vital tumor content and formation of fibrosis. CONCLUSIONS This study demonstrates that dual-modality DRS-AFS provides quantitative functional information that corresponds well with the degree of pathologic response. DRS-AFS, in conjunction with other imaging modalities, could be used to optimize systemic cancer treatment on the basis of early individual tumor response.
Resumo:
BACKGROUND AND AIMS The structured IBD Ahead 'Optimised Monitoring' programme was designed to obtain the opinion, insight and advice of gastroenterologists on optimising the monitoring of Crohn's disease activity in four settings: (1) assessment at diagnosis, (2) monitoring in symptomatic patients, (3) monitoring in asymptomatic patients, and (4) the postoperative follow-up. For each of these settings, four monitoring methods were discussed: (a) symptom assessment, (b) endoscopy, (c) laboratory markers, and (d) imaging. Based on literature search and expert opinion compiled during an international consensus meeting, recommendations were given to answer the question 'which diagnostic method, when, and how often'. The International IBD Ahead Expert Panel advised to tailor this guidance to the healthcare system and the special prerequisites of each country. The IBD Ahead Swiss National Steering Committee proposes best-practice recommendations adapted for Switzerland. METHODS The IBD Ahead Steering Committee identified key questions and provided the Swiss Expert Panel with a structured literature research. The expert panel agreed on a set of statements. During an international expert meeting the consolidated outcome of the national meetings was merged into final statements agreed by the participating International and National Steering Committee members - the IBD Ahead 'Optimized Monitoring' Consensus. RESULTS A systematic assessment of symptoms, endoscopy findings, and laboratory markers with special emphasis on faecal calprotectin is deemed necessary even in symptom-free patients. The choice of recommended imaging methods is adapted to the specific situation in Switzerland and highlights the importance of ultrasonography and magnetic resonance imaging besides endoscopy. CONCLUSION The recommendations stress the importance of monitoring disease activity on a regular basis and by objective parameters, such as faecal calprotectin and endoscopy with detailed documentation of findings. Physicians should not rely on symptoms only and adapt the monitoring schedule and choice of options to individual situations.